The predictors and economic burden of early-, mid- and late-onset cardiac implantable electronic device infections: a retrospective cohort study in Ontario, Canada.

N Daneman1, E Homenauth2, R Saskin2, R Ng2, A Ha3, H C Wijeysundera4.   

Abstract

The rate of cardiac implantable electronic device (CIED) infection is increasing with time. We sought to determine the predictors, relative mortality, and cost burden of early-, mid- and late-onset CIED infections. We conducted a retrospective cohort study of all CIED implantations in Ontario, Canada between April 2013 and March 2016. The procedures and infections were identified in validated, population-wide health-care databases. Infection onset was categorized as early (0-30 days), mid (31-182 days) and late (183-365 days). Cox proportional hazards regression was used to assess the mortality impact of CIED infections, with infection modelled as a time-varying covariate. A generalized linear model with a log-link and γ distribution was used to compare health-care system costs by infection status. Among 17 584 patients undergoing CIED implantation, 215 (1.2%) developed an infection, including 88 early, 85 mid, and 42 late infections. The adjusted hazard ratio (aHR) of death was higher for patients with early (aHR 2.9, 95% CI 1.7-4.9), mid (aHR 3.3, 95% CI 1.9-5.7) and late (aHR 19.9, 95% CI 9.9-40.2) infections. Total mean 1-year health costs were highest for late-onset (mean Can$113 778), followed by mid-onset (mean Can$85 302), and then early-onset (Can$75 415) infections; costs for uninfected patients were Can$25 631. After accounting for patient and procedure characteristics, there was a significant increase in costs associated with early- (rate ratio (RR) 3.1, 95% CI 2.3-4.1), mid- (RR 2.8, 95% CI 2.4-3.3) and late- (RR 4.7, 95% CI 3.6-6.2) onset infections. In summary, CIED infections carry a tremendous clinical and economic burden, and this burden is disproportionately high for late-onset infections.
Copyright © 2019 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cardiac implantable electronic device; Health services research; Prosthetic infection; Surgical site infection

Year:  2019        PMID: 30797886     DOI: 10.1016/j.cmi.2019.02.009

Source DB:  PubMed          Journal:  Clin Microbiol Infect        ISSN: 1198-743X            Impact factor:   8.067


  1 in total

1.  Incidence and Predictors of Infections and All-Cause Death in Patients with Cardiac Implantable Electronic Devices: The Italian Nationwide RI-AIAC Registry.

Authors:  Giuseppe Boriani; Marco Proietti; Matteo Bertini; Igor Diemberger; Pietro Palmisano; Stefano Baccarini; Francesco Biscione; Nicola Bottoni; Antonio Ciccaglioni; Alessandro Dal Monte; Franco Alberto Ferrari; Saverio Iacopino; Marcello Piacenti; Daniele Porcelli; Stefano Sangiorgio; Luca Santini; Michele Malagù; Giuseppe Stabile; Jacopo Francesco Imberti; Davide Caruso; Massimo Zoni-Berisso; Roberto De Ponti; Renato Pietro Ricci
Journal:  J Pers Med       Date:  2022-01-11