Literature DB >> 30796621

Online Sol-gel Capillary Microextraction-Mass Spectrometry (CME-MS) Analysis of Illicit Drugs.

Emre Seyyal1, Theresa Evans-Nguyen2.   

Abstract

Providing rapid and sensitive sample cleanup, sol-gel capillary microextraction (CME) is a form of solid phase microextraction (SPME). The capillary format of CME couples easily with mass spectrometry (MS) by employing sol-gel sorbent coatings in inexpensive fused silica capillaries. By leveraging the syringe pump and six-port valve readily available on the commercial MS, we can obviate the need for chromatography for samples as complex as urine in quantitative assays. Two different sol-gel materials were studied as microextraction sorbents: one with a single ligand of octadecyl (C18) and the other with a dual-ligand combination of C18 and phenyl (Phe) groups. The CME-MS method was optimized for flow rate and solvent desorption and studied for overall microextraction performance between the two sorbents studied. We extract illicit drugs including cocaine, heroin, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, and oxycodone, proving good run-to-run reproducibility (RSD% < 10%) and low detection limits (< 10 ng mL-1). The dual-ligand sorbent demonstrated superior performance due to typical hydrophobic properties of C18 as well as potential π-π interactions of the Phe functionality and the aromatic moiety common to many drugs. This study demonstrates the advantage of fine-tuning sol-gel sorbents for application-specific CME-MS. We apply our method to the analysis of various drugs in synthetic and human urine samples and show low carryover effect (~ 5%) and low matrix effect in the presence of the urine matrix. Thus, the sol-gel CME-MS technique described herein stands to be an attractive alternative to other SPME-MS techniques.

Entities:  

Keywords:  Drugs; Forensics; SPME-MS; Sample preparation; Sol-gel; Solid phase microextraction; Urine analysis

Mesh:

Substances:

Year:  2019        PMID: 30796621     DOI: 10.1007/s13361-018-02127-w

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  40 in total

1.  Determination of volatile organic compounds as biomarkers of lung cancer by SPME-GC-TOF/MS and chemometrics.

Authors:  Joanna Rudnicka; Tomasz Kowalkowski; Tomasz Ligor; Bogusław Buszewski
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2011-09-23       Impact factor: 3.205

2.  Development of a graphite low-temperature plasma source with dual-mode in-source fragmentation for ambient mass spectrometry.

Authors:  Mohammad Reza Almasian; Chengdui Yang; Zhi Xing; Sichun Zhang; Xinrong Zhang
Journal:  Rapid Commun Mass Spectrom       Date:  2010-03       Impact factor: 2.419

3.  Selective and sensitive determination of protoberberines by capillary electrophoresis coupled with molecularly imprinted microextraction.

Authors:  Wenpeng Zhang; Yilin Li; Zilin Chen
Journal:  J Sep Sci       Date:  2015-10-19       Impact factor: 3.645

4.  Sol-gel immobilized cyano-polydimethylsiloxane coating for capillary microextraction of aqueous trace analytes ranging from polycyclic aromatic hydrocarbons to free fatty acids.

Authors:  Sameer Kulkarni; Li Fang; Khalid Alhooshani; Abdul Malik
Journal:  J Chromatogr A       Date:  2006-07-26       Impact factor: 4.759

5.  Detection of "bath salt" synthetic cathinones and metabolites in urine via DART-MS and solid phase microextraction.

Authors:  Joseph LaPointe; Brian Musselman; Teresa O'Neill; Jason R E Shepard
Journal:  J Am Soc Mass Spectrom       Date:  2014-10-15       Impact factor: 3.109

6.  Quantification of monohydroxylated polycyclic aromatic hydrocarbons in human urine samples using solid-phase microextraction coupled with glass-capillary nanoelectrospray ionization mass spectrometry.

Authors:  Bi-Cheng Yang; Shu-Fen Fang; Xiao-Ju Wan; Yong Luo; Jiang-Yan Zhou; You Li; Yun-Jun Li; Feng Wang; Ou-Ping Huang
Journal:  Anal Chim Acta       Date:  2017-04-10       Impact factor: 6.558

7.  Fast Quantitation of Target Analytes in Small Volumes of Complex Samples by Matrix-Compatible Solid-Phase Microextraction Devices.

Authors:  Hamed Piri-Moghadam; Fardin Ahmadi; German Augusto Gómez-Ríos; Ezel Boyacı; Nathaly Reyes-Garcés; Ali Aghakhani; Barbara Bojko; Janusz Pawliszyn
Journal:  Angew Chem Int Ed Engl       Date:  2016-05-09       Impact factor: 15.336

8.  Sol-gel niobia sorbent with a positively charged octadecyl ligand providing enhanced enrichment of nucleotides and organophosphorus pesticides in capillary microextraction for online HPLC analysis.

Authors:  Sheshanka Kesani; Abdul Malik
Journal:  J Sep Sci       Date:  2018-01-30       Impact factor: 3.645

9.  Sol-gel molecular imprinted ormosil for solid-phase extraction of methylxanthines.

Authors:  Raquel Gomes da Costa Silva; Fabio Augusto
Journal:  J Chromatogr A       Date:  2006-04-17       Impact factor: 4.759

10.  High pH-resistant, surface-bonded sol-gel titania hybrid organic-inorganic coating for effective on-line hyphenation of capillary microextraction (in-tube solid-phase microextraction) with high-performance liquid chromatography.

Authors:  Tae-Young Kim; Khalid Alhooshani; Abuzar Kabir; David P Fries; Abdul Malik
Journal:  J Chromatogr A       Date:  2004-08-27       Impact factor: 4.759

View more
  2 in total

Review 1.  Interpol review of controlled substances 2016-2019.

Authors:  Nicole S Jones; Jeffrey H Comparin
Journal:  Forensic Sci Int Synerg       Date:  2020-05-24

2.  Molecular imaging of humain hair with MeV-SIMS: A case study of cocaine detection and distribution in the hair of a cocaine user.

Authors:  Luka Jeromel; Nina Ogrinc; Zdravko Siketić; Primož Vavpetič; Zdravko Rupnik; Klemen Bučar; Boštjan Jenčič; Mitja Kelemen; Matjaž Vencelj; Katarina Vogel-Mikuš; Janez Kovač; Ron M A Heeren; Bryn Flinders; Eva Cuypers; Žiga Barba; Primož Pelicon
Journal:  PLoS One       Date:  2022-03-25       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.