Literature DB >> 30794257

Capacity to Maintain Placement Torque at Removal, Single Load-to-Failure, and Stress Concentration of Straight and Angled Abutments.

Michelle Paulino Sousa, João Paulo Mendes Tribst, Amanda Maria de Oliveira Dal Piva, Alexandre Luiz Souto Borges, Sérgio de Oliveira, Paulo César da Cruz.   

Abstract

Because the main complication of implant-supported prostheses is torque loosening and/or fixation screw fracture, the goal of this study was to evaluate the torque before and after fatigue (screw placement and removal, respectively), single load-to-failure (compression test), and stress concentration of straight and angled abutments. Eighty implants were included in polyurethane cylinders. Half of the implants received straight abutments (group S, n = 40) and the other half received angled abutments (group A, n = 40). The abutments for cemented prostheses were installed with a torque of 20 Ncm. Eighty titanium structures were machined and cemented on the abutments with zinc-phosphate cement. After storage for 24 hours, half of the specimens had their torque loosening evaluated and were then immediately submitted to a compressive test in a universal testing machine (1 mm/minute, 1,000 kgf), while the other half were subjected to cyclic fatigue (200 N at 2 Hz for 2 × 106 cycles at 37°C) as an aging protocol (n = 20 from each group). The aged samples then had their torque loosening measured and were also submitted to the compression test. Representative samples were evaluated by scanning electron microscopy. Two bidimensional models similar to the in vitro specimens were created and analyzed using the finite element method to evaluate the stress concentration. Data from the in vitro tests were submitted to two-way analysis of variance and Tukey test, both with significance at P = .5. The results show that angled abutments are less capable of maintaining the installation torque and are less resistant during the single load-to-failure test. The von Mises stress concentration was higher for group A in the cervical region. The straight abutments have better prognosis than angled abutments and less susceptibility to mechanical failures.

Entities:  

Mesh:

Year:  2019        PMID: 30794257     DOI: 10.11607/prd.3998

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  5 in total

1.  Effect of framework type on survival probability of implant-supported temporary crowns: An in vitro study.

Authors:  Vinícius-Anéas Rodrigues; Amanda-Maria-de Oliveira Dal Piva; Claudio-Akira Yamaguchi; Alexandre-Luiz-Souto Borges; Marcio-Katsuyoshi Mukai; João-Paulo-Mendes Tribst
Journal:  J Clin Exp Dent       Date:  2020-05-01

2.  Effect of the restorative technique on load-bearing capacity, cusp deflection, and stress distribution of endodontically-treated premolars with MOD restoration.

Authors:  Daniel Maranha da Rocha; João Paulo Mendes Tribst; Pietro Ausiello; Amanda Maria de Oliveira Dal Piva; Milena Cerqueira da Rocha; Rebeca Di Nicoló; Alexandre Luiz Souto Borges
Journal:  Restor Dent Endod       Date:  2019-08-07

3.  Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit.

Authors:  Jorge Vélez; Jesús Peláez; Carlos López-Suárez; Rubén Agustín-Panadero; Celia Tobar; María J Suárez
Journal:  J Clin Med       Date:  2020-07-24       Impact factor: 4.241

4.  Mechanical behavior of implant assisted removable partial denture for Kennedy class II.

Authors:  João-Paulo-Mendes Tribst; Rodrigo-Máximo de Araújo; Naiara-Pires Ramanzine; Natália-Ribeiro Santos; Amanda-Maria-de Oliveira Dal Piva; Alexandre-Luiz-Souto Borges; João-Mauricio-Ferraz da Silva
Journal:  J Clin Exp Dent       Date:  2020-01-01

5.  Stress distribution of complete-arch implant-supported prostheses reinforced with silica-nylon mesh.

Authors:  Tarcisio-José de A Paes-Junior; João-Paulo-Mendes Tribst; Amanda-Maria-de Oliveira Dal Piva; Marina Amaral; Alexandre-Luiz-Souto Borges; Fernanda-de-Cássia-Papaiz Gonçalves
Journal:  J Clin Exp Dent       Date:  2019-12-01
  5 in total