Literature DB >> 30775377

IQOS exposure impairs human airway cell homeostasis: direct comparison with traditional cigarette and e-cigarette.

Sukhwinder Singh Sohal1, Mathew Suji Eapen1, Vegi G M Naidu2, Pawan Sharma3,4.   

Abstract

Heat-not-burn (HNB) devices can alter vital physiological functions in the lung. HNB devices may not be a safer option than cigarette smoking or eCig vaping; this does not support the recommendation of their use over other nicotine delivery products. http://ow.ly/wZ5P30ng8bU.

Entities:  

Year:  2019        PMID: 30775377      PMCID: PMC6368999          DOI: 10.1183/23120541.00159-2018

Source DB:  PubMed          Journal:  ERJ Open Res        ISSN: 2312-0541


To the Editor: While cigarette smoking still remains one of the most pressing global health issues of our time, newer forms of smoking device have been introduced across the globe in the last decade [1]. Electronic nicotine/non-nicotine delivery systems commonly known as electronic cigarettes (eCig) heat a solution (e-liquid) to create vapour [2]; the latest addition to this list is the introduction of heat-not-burn (HNBs) tobacco products branded as IQOS [3]. HNBs are hybrids between eCigs and traditional cigarettes i.e. they are equipped with a device that heats the product, without burning to generate aerosol and the product being heated is not a liquid but real tobacco [4, 5]. eCig vaping is comparatively new but its use is increasing at an alarming rate; it is believed it will surpass the use of traditional cigarettes in next 5 years, with global sales reaching US$10 billion [6]. Since its launch in Italy and Japan in 2014, IQOS has become the leader in the HNB market [4, 7]. To date, IQOS is available in 41 countries, including 22 from the WHO-European region, and its market share has now reached the level of cigars in Italy [4]. Emerging data shows that eCig use, particularly in the young, is associated with future cigarette use [8]. Similarly, over half of the people interested in IQOS are never-smokers [4]. Therefore, both eCigs and IQOS may represent a gateway for nicotine addiction among never-smokers rather than a substitute used for harm-reduction purposes in current smokers [4]. It is now clear that eCig vapour contains high levels of toxic compounds [9], which adversely affect respiratory, gastrointestinal and cardiovascular systems both in vitro and in vivo [10-12]. It is also important to recognise that IQOS products are comparatively new but emerging research suggests that IQOS emits substantially high levels of carbonyls [13]. There is as yet no published comparison between the effect of eCigs, IQOS and tobacco smoke on human lungs. Here, we examine whether exposure to IQOS has the same damaging effect on human airway epithelial and smooth muscle cells as traditional tobacco cigarette and eCigs in vitro. We used human bronchial epithelial cells (Beas-2B, ATCC CRL-9609) and primary human airway smooth muscle (ASM) cells (ATCC PCS-130-010). eCig vapour was generated using an eCig device (KangerTech 3rd Generation; KangerTech, Shenzhen, China) and e-liquid (Blu, Charlotte, NC, USA) (1.2% nicotine); IQOS aerosol was generated using HNB heat-sticks (Philip Morris, Tokyo, Japan) (1.4 mg nicotine); and cigarette-smoke-extract (CSE) was generated using Marlboro Red cigarettes (Philip Morris, Washington, DC, USA) (1.2 mg nicotine). eCig vapour/IQOS aerosol/cigarette smoke was “bubbled” through a T-75 flask containing 25-mL media at a constant rate with modification [14-18]. This freshly generated (100%) eCig vapour, IQOS aerosol and CSE were diluted to the final working concentration and used immediately. Beas-2B or primary human ASM cells were treated with increasing concentrations of CSE, eCig vapour or IQOS aerosol for 72 h, and cell cytotoxicity (Thaizolyl blue tetrazolium bromide (MTT) and lactate dehydrogenase (LDH)), chemokine release (CXCL8), extracellular matrix (ECM) (collagen 1 and fibronectin) release and mitochondrial respiration (glycolysis and proton leak) were measured. GraphPad (La Jolla, CA, USA) was used for statistical analysis using one-way ANOVA followed by Bonferroni's multiple comparison test. Using two different cytotoxicity assays (MTT and LDH), CSE, eCig or IQOS exposure showed cellular toxicity with increasing concentration (figure 1a–h). A CSE concentration of >10% is highly toxic; therefore, we only used concentrations <10% in our experiments, which is also used widely in many studies [14-18]. In both Beas-2B and ASM cells, we found that CSE exposure significantly reduced cell viability and increased LDH release at 1, 5 and 10% (figure 1i–n). eCig exposure showed similar toxicity at 5 and 10% exposure. Interestingly, IQOS exposure was as toxic as CSE at 1, 5 and 10%. It is evident that both CSE and eCig vapour can induce inflammation in the lung [18, 19], and as shown in figure 1a–h), CSE exposure in a concentration-dependent manner induced the release of CXCL8 in Beas-2B (figure 1a) and ASM cells (figure 1e). eCig exposure induced CXCL8 release at the highest concentration, whereas IQOS exposure showed a similar induction to CSE, suggesting that IQOS is as effective as CSE in inducing chemokine release from both types of airway cells. Next, we measured the induction of ECM proteins with airway cells; CSE, eCig and IQOS exposure in a concentration-dependent manner increased collagen 1 (figure 1b and f) and fibronectin (figure 1c and g) release with both Beas-2B (figure 1b and c) and ASM (figure 1c and g) cells. Finally, we measured mitochondrial respiration using a seahorse analyser, and found that CSE, eCig and IQOS exposure increased the extracellular acidification rate (a measure of glycolysis) (figure 1a–h) and proton leak (a measure of mitochondrial uncoupling) (figure 1i–n) in both Beas-2B (figure 1d) and ASM (figure 1h) cells, respectively.
FIGURE 1

a–h) Comparison of the effects of cigarette smoke extract (CSE), electronic cigarette (eCig) vapour and IQOS aerosol exposure on a–d) human airway epithelial (Beas-2B) and e–h) human airway smooth muscle (ASM) cells. a and e) show the release of CXCL8 from Beas-2B and ASM cells. The concentration of CXCL8 in supernatant from Beas-2B and ASM cells after 72 h of stimulation with CSE, eCig vapour or IQOS aerosol exposure was measured using ELISA. Deposition of b and f) collagen I alpha 1 (COL1A1) and c and g) fibronectin from Beas-2B and human ASM cells after 72 h of stimulation with CSE, eCig vapour or IQOS aerosol exposure was measured using extracellular matrix (ECM) ELISA at an absorbance of 450 nm and 570 nm, respectively. d and h) The level of glycolysis was determined in Beas-2B and ASM cells using a seahorse analyser, and extracellular acidification rate (ECAR); an index of glycolysis was measured after 72 h of stimulation with CSE, eCig vapour or IQOS aerosol exposure. Data are presented as mean±sem (n=5–7). i–n) The effect of CSE, eCig and IQOS exposure on cellular toxicity and respiration. The cell viability (i and l), the lactate dehydrogenase (LDH) release (j and m) and the mitochondrial respiration (k and n) from Beas-2B and human ASM cells was measured using Thaizolyl blue tetrazolium bromide (MTT) and LDH assays at an absorbance of 570 nm and 490 nm, respectively. k and n) Mitochondrial respiration was measured in Beas-2B and ASM cells using a mito-stress kit on a seahorse analyser (Agilent Technologies Inc., Santa Clara, CA, USA), and proton leak was measured as oxygen consumption rate shown as fold change to control. Cells were stimulated with serial dilution of CSE, eCig vapour or IQOS aerosol for 72 h (n=5). Data are presented as mean±sem. A one-way ANOVA plus Bonferroni post-test was used to determine statistical significance. *: p<0.05 compared with control; **: p<0.01 compared with control; ***: p<0.001 compared with control.

a–h) Comparison of the effects of cigarette smoke extract (CSE), electronic cigarette (eCig) vapour and IQOS aerosol exposure on a–d) human airway epithelial (Beas-2B) and e–h) human airway smooth muscle (ASM) cells. a and e) show the release of CXCL8 from Beas-2B and ASM cells. The concentration of CXCL8 in supernatant from Beas-2B and ASM cells after 72 h of stimulation with CSE, eCig vapour or IQOS aerosol exposure was measured using ELISA. Deposition of b and f) collagen I alpha 1 (COL1A1) and c and g) fibronectin from Beas-2B and human ASM cells after 72 h of stimulation with CSE, eCig vapour or IQOS aerosol exposure was measured using extracellular matrix (ECM) ELISA at an absorbance of 450 nm and 570 nm, respectively. d and h) The level of glycolysis was determined in Beas-2B and ASM cells using a seahorse analyser, and extracellular acidification rate (ECAR); an index of glycolysis was measured after 72 h of stimulation with CSE, eCig vapour or IQOS aerosol exposure. Data are presented as mean±sem (n=5–7). i–n) The effect of CSE, eCig and IQOS exposure on cellular toxicity and respiration. The cell viability (i and l), the lactate dehydrogenase (LDH) release (j and m) and the mitochondrial respiration (k and n) from Beas-2B and human ASM cells was measured using Thaizolyl blue tetrazolium bromide (MTT) and LDH assays at an absorbance of 570 nm and 490 nm, respectively. k and n) Mitochondrial respiration was measured in Beas-2B and ASM cells using a mito-stress kit on a seahorse analyser (Agilent Technologies Inc., Santa Clara, CA, USA), and proton leak was measured as oxygen consumption rate shown as fold change to control. Cells were stimulated with serial dilution of CSE, eCig vapour or IQOS aerosol for 72 h (n=5). Data are presented as mean±sem. A one-way ANOVA plus Bonferroni post-test was used to determine statistical significance. *: p<0.05 compared with control; **: p<0.01 compared with control; ***: p<0.001 compared with control. Cigarette smoking has been linked to chronic lung diseases such as chronic obstructive pulmonary disease (COPD), asthma, pulmonary fibrosis, cancer and related comorbidities [1]. It took us nearly five decades to understand the detrimental effects of cigarette smoke on humans. Long-term eCig-exposure studies in humans are currently sparse, limiting our understanding of its direct effect(s) on both disease development and progression. eCig vaping is already at its highest level globally, and many countries are imposing stringent regulations in light of the emerging evidence showing the adverse effects of vaping on human health. IQOS use is comparatively new; it will take years before we start to know its detrimental effect on human health. We demonstrate here for the first time that IQOS exposure is as detrimental as cigarette smoking and vaping to human lung cells. Persistent allergic, smoke or environmental-triggered inflammation leads to airway remodelling/scarring through re-organisation of ECM and airway cell proliferation, and mitochondrial dysfunction plays a pivotal role in this process. These are the principal causes for airflow limitation in asthma and COPD. Here, we have analysed all of these mechanisms: inflammation (CXCL8), ECM release (collagen 1 and fibronectin) and mitochondrial respiration (glycolysis and proton leak). We observed collagen-1 and fibronectin induction by both Beas-2B and ASM cells to CSE, eCig and IQOS exposure. ECM proteins facilitate the conversion of mesenchymal cells to ECM secreting active myofibroblasts and epithelial mesenchymal transition (EMT) in chronic lung disease [20, 21]. Our data suggests that like eCigs and traditional cigarettes, IQOS exposure contributes to altered mitochondrial function which can further exaggerate airway inflammation, airway remodelling and lung cancer through active EMT, as seen in smokers [22]. It is widely understood that mitochondria of airway epithelium and mesenchymal cells play differential roles, consistent with their contributions to disease and essential for cell existence. Mitochondrial dysfunction also underpins many normal physiological processes and in certain pathological conditions, such as obesity or with an oxidant trigger such as smoke, eCigs and IQOS, it may impact lung diseases. Cigarette smoking and eCigs can exaggerate respiratory infections by increasing microbial adherence to the airways [23, 24]; IQOS may increase respiratory infections through similar mechanisms. Given our current findings and those of previous studies, in a manner very similar to cigarette smoke and eCigs, IQOS has the potential to increase oxidative stress and inflammation, infections, airway remodelling and initiate EMT-related changes in the airways of users of these devices. However, prospective clinical studies must be conducted to verify our in vitro, cell-based but highly important and novel findings on IQOS.
  26 in total

1.  Will the Swiss pavilion at Expo 2020 Dubai damage your health?

Authors:  Nino Künzli; Milo A Puhan; L Suzanne Suggs
Journal:  Int J Public Health       Date:  2019-07-30       Impact factor: 3.380

Review 2.  An Overview of iQOS® as a New Heat-Not-Burn Tobacco Product and Its Potential Effects on Human Health and the Environment.

Authors:  Rahman Başaran; Naile Merve Güven; Benay Can Eke
Journal:  Turk J Pharm Sci       Date:  2019-07-10

3.  Pod-based menthol and tobacco flavored e-cigarettes cause mitochondrial dysfunction in lung epithelial cells.

Authors:  Thomas Lamb; Thivanka Muthumalage; Irfan Rahman
Journal:  Toxicol Lett       Date:  2020-08-09       Impact factor: 4.372

4.  Acute Effects of Heated Tobacco Product (IQOS) Aerosol Inhalation on Lung Tissue Damage and Inflammatory Changes in the Lungs.

Authors:  Tariq A Bhat; Suresh G Kalathil; Noel Leigh; Thivanka Muthumalage; Irfan Rahman; Maciej L Goniewicz; Yasmin M Thanavala
Journal:  Nicotine Tob Res       Date:  2021-06-08       Impact factor: 4.244

5.  COVID-19 and smoking: More severity and death - An experience from Iran.

Authors:  Gholamreza Heydari; Hossein Arfaeinia
Journal:  Lung India       Date:  2021-03

6.  Knowledge about E-Cigarettes and Tobacco Harm Reduction among Public Health Residents in Europe.

Authors:  Pietro Ferrara; Saran Shantikumar; Vítor Cabral Veríssimo; Rafael Ruiz-Montero; Cristina Masuet-Aumatell; Josep Maria Ramon-Torrell
Journal:  Int J Environ Res Public Health       Date:  2019-06-12       Impact factor: 3.390

7.  There can be smoke without fire: warranted caution in promoting electronic cigarettes and heat not burn devices as a safer alternative to cigarette smoking.

Authors:  Kielan Darcy McAlinden; Sukhwinder Singh Sohal; Pawan Sharma
Journal:  ERJ Open Res       Date:  2019-08-12

Review 8.  Heated Tobacco Products: A Review of Current Knowledge and Initial Assessments.

Authors:  Nadja Mallock; Elke Pieper; Christoph Hutzler; Frank Henkler-Stephani; Andreas Luch
Journal:  Front Public Health       Date:  2019-10-10

Review 9.  Exposure to Heated Tobacco Products and Adverse Health Effects, a Systematic Review.

Authors:  Małgorzata Znyk; Joanna Jurewicz; Dorota Kaleta
Journal:  Int J Environ Res Public Health       Date:  2021-06-21       Impact factor: 3.390

10.  Acute Effects of a Heat-Not-Burn Tobacco Product on Pulmonary Function.

Authors:  Athanasia Pataka; Seraphim Kotoulas; Evangelos Chatzopoulos; Ioanna Grigoriou; Konstantinos Sapalidis; Christoforos Kosmidis; Anastasios Vagionas; Εleni-Isidora Perdikouri; Konstantinos Drevelegas; Paul Zarogoulidis; Paraskevi Argyropoulou
Journal:  Medicina (Kaunas)       Date:  2020-06-12       Impact factor: 2.430