Abstract

OBJECTIVE: To establish a complete workflow of digital design and manufacturing occlusal splint for sleep bruxism, which can be preliminarily applied in clinical use, thus observe the clinical efficacy.
METHODS: Twenty-four patients with sleep bruxism were recruited in the study and randomly divided into two groups by using random number tables. Digital-occlusal-splint (experimental group) treatment plan and traditional-occlusal-splint (control-group) treatment plan were carried out for each group, respectively. For experimental group, digital models of patients' both dental arches and the occlusion relationship after elevation were captured using an intraoral scanner. The occlusal splint was carried out by computer aided design/computer aided manufacturing (CAD/CAM), including splint designing and milling. For control group, the traditional soft occlusal splint was fabricated by vacuum laminator. The two kinds of occlusal splints were tried in the patients from each group, and the occlusal contacts were tested respectively by T-scan analysis system, which recorded the changes of occlusal indicators in the two groups. The retention, appearance and occlusal comfort degree were evaluated by the two groups of patients. Mann-Whitney test was performed with IBM SPSS 20.0 software, and bilateral test was performed. P<0.05 was considered to be statistically significant.
RESULTS: The complete workflow of digital design and manufacturing occlusal splint was successfully established. During the clinical use, there was no statistical difference in the retention evaluation of two kinds of occlusal splints between the two groups of patients (Z=-0.538, P=0.590). The appearance score (Z=2.038, P=0.042) and the occlusal comfort score (Z=-2.579, P=0.010) of the experimental group were higher than those of the control group, with statistically significant differences. The T-scan analysis results showed that only the second molar on both sides of the traditional occlusal splint had occlusal contact in intercupsal position, while the digital occlusal splint had stable and bilaterally balanced contact between the maxillary and mandibular teeth. Furthermore, the occlusal force was uniformly distributed in the experimental group.
CONCLUSION: The complete workflow of digital occlusal splint improves the occlusal design, greatly simplifies and optimizes the traditional process of making occlusal splint. This new method is resource-saving and environmental-friendly, and it is able to serve patients more conveniently and efficiently.

Entities:  

Mesh:

Year:  2019        PMID: 30773553      PMCID: PMC7433544          DOI: 10.19723/j.issn.1671-167X.2019.01.019

Source DB:  PubMed          Journal:  Beijing Da Xue Xue Bao Yi Xue Ban        ISSN: 1671-167X


  9 in total

1.  Quantitative polygraphic controlled study on efficacy and safety of oral splint devices in tooth-grinding subjects.

Authors:  C Dubé; P H Rompré; C Manzini; F Guitard; P de Grandmont; G J Lavigne
Journal:  J Dent Res       Date:  2004-05       Impact factor: 6.116

2.  The Use of a Modified Poly-Ether-Ether-Ketone (PEEK) as an Alternative Framework Material for Removable Dental Prostheses. A Clinical Report.

Authors:  Panagiotis Zoidis; Ioannis Papathanasiou; Gregory Polyzois
Journal:  J Prosthodont       Date:  2015-07-27       Impact factor: 2.752

3.  A digital process for additive manufacturing of occlusal splints: a clinical pilot study.

Authors:  Mika Salmi; Kaija-Stiina Paloheimo; Jukka Tuomi; Tuula Ingman; Antti Mäkitie
Journal:  J R Soc Interface       Date:  2013-04-24       Impact factor: 4.118

4.  A Novel Computer-Aided Design/Computer-Assisted Manufacture Method for One-Piece Removable Partial Denture and Evaluation of Fit.

Authors:  Hongqiang Ye; Xinxin Li; Guanbo Wang; Jing Kang; Yushu Liu; Yuchun Sun; Yongsheng Zhou
Journal:  Int J Prosthodont       Date:  2018-02-15       Impact factor: 1.681

Review 5.  Epidemiology of bruxism in adults: a systematic review of the literature.

Authors:  Daniele Manfredini; Ephraim Winocur; Luca Guarda-Nardini; Daniel Paesani; Frank Lobbezoo
Journal:  J Orofac Pain       Date:  2013

Review 6.  Bruxism physiology and pathology: an overview for clinicians.

Authors:  G J Lavigne; S Khoury; S Abe; T Yamaguchi; K Raphael
Journal:  J Oral Rehabil       Date:  2008-07       Impact factor: 3.837

7.  Evaluation of the effect of two different occlusal splints on maximum occlusal force in patients with sleep bruxism: a pilot study.

Authors:  Duygu Karakis; Arife Dogan; Bulent Bek
Journal:  J Adv Prosthodont       Date:  2014-04-22       Impact factor: 1.904

8.  Current Treatments of Bruxism.

Authors:  Marc Guaita; Birgit Högl
Journal:  Curr Treat Options Neurol       Date:  2016-02       Impact factor: 3.598

9.  Clinical comparison of conventional and additive manufactured stabilization splints.

Authors:  Christian Berntsen; Martin Kleven; Marianne Heian; Carl Hjortsjö
Journal:  Acta Biomater Odontol Scand       Date:  2018-08-13
  9 in total
  1 in total

1.  [Preliminary clinical application verification of complete digital workflow of design lips symmetry reference plane based on posed smile].

Authors:  S T Qiu; Y J Zhu; S M Wang; F L Wang; H Q Ye; Y J Zhao; Y S Liu; Y Wang; Y S Zhou
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2022-02-18
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.