Literature DB >> 29448267

A Novel Computer-Aided Design/Computer-Assisted Manufacture Method for One-Piece Removable Partial Denture and Evaluation of Fit.

Hongqiang Ye, Xinxin Li, Guanbo Wang, Jing Kang, Yushu Liu, Yuchun Sun, Yongsheng Zhou.   

Abstract

PURPOSE: To investigate a computer-aided design/computer-aided manufacturing (CAD/CAM) process for producing one-piece removable partial dentures (RPDs) and to evaluate their fits in vitro.
MATERIALS AND METHODS: A total of 15 one-piece RPDs were designed using dental CAD and reverse engineering software and then fabricated with polyetheretherketone (PEEK) using CAM. The gaps between RPDs and casts were measured and compared with traditional cast framework RPDs.
RESULTS: Gaps were lower for one-piece PEEK RPDs compared to traditional RPDs.
CONCLUSION: One-piece RPDs can be manufactured by CAD/CAM, and their fits were better than those of traditional RPDs.

Entities:  

Year:  2018        PMID: 29448267     DOI: 10.11607/ijp.5508

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  5 in total

1.  [Preliminary clinical application of complete digital workflow of design and manufacturing occlusal splint for sleep bruxism].

Authors:  S M Wang; Z Li; G B Wang; H Q Ye; Y S Liu; D Tong; W H Gao; Y S Zhou
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2019-02-18

Review 2.  [Independent innovation research, development and transformation of precise bionic repair technology for oral prosthesis].

Authors:  Y C Sun; Y Q Guo; H Chen; K H Deng; W W Li
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2022-02-18

Review 3.  A Scoping Review on the Accuracy of Fit of Removable Partial Dentures in a Developing Digital Context.

Authors:  Noor Al Mortadi; Karem H Alzoubi; Robert Williams
Journal:  Clin Cosmet Investig Dent       Date:  2020-11-19

4.  Casting over Metal Method Used in Manufacturing Hybrid Cobalt-Chromium Dental Prosthetic Frameworks Assembles.

Authors:  Willi Andrei Uriciuc; Horatiu Vermesan; Ancuta Elena Tiuc; Aranka Ilea; Adina Bianca Bosca; Catalin Ovidiu Popa
Journal:  Materials (Basel)       Date:  2021-01-23       Impact factor: 3.623

5.  Fit Accuracy of Removable Partial Denture Frameworks Fabricated with CAD/CAM, Rapid Prototyping, and Conventional Techniques: A Systematic Review.

Authors:  Naseer Ahmed; Maria Shakoor Abbasi; Sara Haider; Nimra Ahmed; Syed Rashid Habib; Sara Altamash; Muhammad Sohail Zafar; Mohammad Khursheed Alam
Journal:  Biomed Res Int       Date:  2021-09-06       Impact factor: 3.411

  5 in total