Literature DB >> 30773548

[Diagnostic accuracy of cone beam computed tomography with different resolution settings for external root resorption].

X Y Xie1, S M Jia2, Z H Sun3, Z Y Zhang1.   

Abstract

OBJECTIVE: To evaluate the diagnostic accuracy of cone beam computed tomography (CBCT) with different resolution settings in detecting the simulated external root resorption defects.
METHODS: External root resorption defects were simulated in 51 human single rooted premolar teeth. Cavities simulating root resorption defects of 1 mm in diameter and 0.1 mm, 0.2 mm, and 0.3 mm in depth were drilled in the cervical, middle and apical thirds of lingual surfaces of the teeth. In addition to the 51 locations as controls, a total of 102 cavities were obtained in the present study. Specimens were placed in a human dry mandible and scanned by ProMax 3D and DCT PRO CBCT with different resolution settings, respectively. The three-dimensional CBCT images were evaluated by two experienced observers. The data were analyzed with receiver operating characteristics (ROC) analysis. ROC curves were generated and the area under ROC curve (Az) was employed to express the diagnostic accuracy.
RESULTS: The diagnostic accuracy (Az value) of ProMax 3D CBCT with high, normal and low resolution settings were 0.867, 0.703 and 0.665 (P < 0.05), respectively. Defects with depths of 0.2 mm and 0.3 mm were easier to be detected than those with depths of 0.1 mm (P < 0.05). The images obtained by high resolution mode scanning had obvious advantages in detecting smaller defects (depth 0.1 mm and 0.2 mm). The DCT PRO CBCT provided 4 resolution settings including normal quality + normal resolution, normal quality + high resolution, high quality + normal resolution and high quality + high resolution. The Az values for those 4 resolution settings were 0.527, 0.725, 0.743, and 0.794 (P < 0.05), respectively. Similar to ProMax 3D CBCT, the scanning mode with high resolution played a better role in detecting the defects with depth of 0.1 mm. Except for the scanning setting mode with normal quality + normal resolution, the other three modes could well be evaluated for the defects with depth of 0.2 mm and 0.3 mm.
CONCLUSION: It is concluded that the diagnostic ability for external root resorption of CBCT could be affected by resolution settings. Computer-aid imaging method can improve the CBCT diagnostic accuracy for external root resorption without increasing the radiation dose level during CBCT scanning.

Entities:  

Mesh:

Year:  2019        PMID: 30773548      PMCID: PMC7433556          DOI: 10.19723/j.issn.1671-167X.2019.01.014

Source DB:  PubMed          Journal:  Beijing Da Xue Xue Bao Yi Xue Ban        ISSN: 1671-167X


  16 in total

1.  Comparative study of cone beam computed tomography and intraoral periapical radiographs in diagnosis of lingual-simulated external root resorptions.

Authors:  Ricardo Affonso Bernardes; Renata Silvéria de Paulo; Luciana Oliveira Pereira; Marco Antonio Hungaro Duarte; Ronald Ordinola-Zapata; José Ribamar de Azevedo
Journal:  Dent Traumatol       Date:  2012-01-11       Impact factor: 3.333

2.  Diagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorption.

Authors:  C Durack; S Patel; J Davies; R Wilson; F Mannocci
Journal:  Int Endod J       Date:  2010-11-17       Impact factor: 5.264

3.  [Diagnostic accuracy of cone beam computed tomography and eight-slice computed tomography for evaluation of external root reabsorption].

Authors:  Xiao-yan Xie; Zu-yan Zhang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2012-08-18

4.  Receiver operating characteristic (ROC) analysis: basic principles and applications in radiology.

Authors:  A R van Erkel; P M Pattynama
Journal:  Eur J Radiol       Date:  1998-05       Impact factor: 3.528

5.  Assessment of Root Perforation within Simulated Internal Resorption Cavities Using Cone-beam Computed Tomography.

Authors:  Leila Khojastepour; Fariborz Moazami; Mahbod Babaei; Maryam Forghani
Journal:  J Endod       Date:  2015-05-27       Impact factor: 4.171

6.  Accuracy of Digital Periapical Radiography and Cone-beam Computed Tomography for Diagnosis of Natural and Simulated External Root Resorption.

Authors:  Ângela Graciela Deliga Schröder; Fernando Henrique Westphalen; Julio Cesar Schröder; Ângela Fernandes; Vânia Portela Ditzel Westphalen
Journal:  J Endod       Date:  2018-06-05       Impact factor: 4.171

7.  Short-term effects of nicotine on orthodontically induced root resorption in rats.

Authors:  Jing Li; Xuxia Wang; Na Li; Dehua Zhenga; Yuran Su; Jun Zhang
Journal:  Angle Orthod       Date:  2015-06-17       Impact factor: 2.079

Review 8.  Cone Beam Computed Tomography.

Authors:  Ibrahim Nasseh; Wisam Al-Rawi
Journal:  Dent Clin North Am       Date:  2018-07

9.  Root resorption--diagnosis, classification and treatment choices based on stimulation factors.

Authors:  Zvi Fuss; Igor Tsesis; Shaul Lin
Journal:  Dent Traumatol       Date:  2003-08       Impact factor: 3.333

10.  Root resorption diagnosed with cone beam computed tomography after 6 months and at the end of orthodontic treatment with fixed appliances.

Authors:  Dimitrios Makedonas; Henrik Lund; Ken Hansen
Journal:  Angle Orthod       Date:  2012-10-23       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.