Literature DB >> 30771010

Simultaneous extraction of 32 polychlorinated biphenyls by using magnetic carbon nanocomposite based dispersive microextraction, subsequent dispersive liquid-liquid microextraction with two miscible stripping solvents, and quantitation by GC-μECD.

Najmeh Yazdanfar1,2, Mojtaba Shamsipur3, Mahnaz Ghambarian4.   

Abstract

A highly sensitive new method is described for performing dispersive microextractions. It is making use of a magnetic carbon nanocomposite and two miscible organic solvents. The method was applied to simultaneous extraction of 32 polychlorinated biphenyls (PCBs) prior to their quantitation by gas chromatography with electron capture detection. The effects of pH value of sample for both micro solid phase extraction and dispersive liquid-liquid microextraction, of the amount of sorbent, extraction time, type and volume of the miscible organic solvents and of salt addition were optimized. Figures of merit obtained under optimized conditions (sample solution: 500 ml, volume of disperser solvent, ACN, 1.5 mL; volume of extraction solvent, TCB, 30 μL; extraction time: 50 min, 20 mg magnetic sorbent, centrifuge, 5 min, 4000 rpm), include (a) preconcentration factors between 10,880 and 34,000; (b) repeatabilities of ≤14.9%, (c) detection limits between 0.01 and 0.2 ng kg-1, and (d) linear dynamic ranges from 0.05 to 100 ng kg - 1. The method was applied to the simultaneous analysis of residues in (spiked) real samples of fish, milk, packing sheet, and tap waters. Some of the analytes were found to be present in fish samples. The method is simple, rapid, and more sensitive than any of the previously reported ones. Graphical abstract Schematic presentation of simultaneous extraction of 32 polychlorinated biphenyls (PCBs) by using magnetic carbon nanocomposites (MCNs) based dispersive microextraction (M-SPE), subsequent dispersive liquid-liquid microextraction (DLLME) with two miscible stripping solvents, and quantitation by GC-μECD.

Entities:  

Keywords:  Dispersive microextraction; Fish analysis; Gas chromatography with micro electron capture detector; Magnetic carbon nanocomposite; Milk analysis; Miscible organic solvents magnetic solid-phase extraction; Packing sheet; Polychlorinated biphenyls

Year:  2019        PMID: 30771010     DOI: 10.1007/s00604-019-3235-x

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  25 in total

1.  Recent advances in applications of single-drop microextraction: a review.

Authors:  Archana Jain; Krishna K Verma
Journal:  Anal Chim Acta       Date:  2011-08-22       Impact factor: 6.558

2.  Optimization of solid-phase microextraction of volatile phenols in water by a polyaniline-coated Pt-fiber using experimental design.

Authors:  M Mousavi; E Noroozian; M Jalali-Heravi; A Mollahosseini
Journal:  Anal Chim Acta       Date:  2006-08-05       Impact factor: 6.558

3.  Dispersive liquid-liquid microextraction based on the solidification of floating organic droplet for the determination of polychlorinated biphenyls in aqueous samples.

Authors:  Liping Dai; Jing Cheng; Guzalnur Matsadiq; Lu Liu; Jun-Kai Li
Journal:  Anal Chim Acta       Date:  2010-06-26       Impact factor: 6.558

4.  Determination of organochlorine pesticides and polychlorinated biphenyls in post-mortem human lung by matrix solid-phase dispersion with the aid of response surface methodology and desirability function.

Authors:  Georgios N Rallis; Vasilios A Sakkas; Vassiliki A Boumba; Theodore Vougiouklakis; Triantafyllos A Albanis
Journal:  J Chromatogr A       Date:  2012-01-08       Impact factor: 4.759

5.  Sample pretreatment method for the determination of polychlorinated biphenyls in bird livers using ultrasonic extraction followed by headspace solid-phase microextraction and gas chromatography-mass spectrometry.

Authors:  Dimitra A Lambropoulou; Ioannis K Konstantinou; Triantafyllos A Albanis
Journal:  J Chromatogr A       Date:  2006-06-14       Impact factor: 4.759

6.  Determination of polychlorinated biphenyls and organochlorine pesticides in human serum by gas chromatography with micro-electron capture detector.

Authors:  Lu-Lu Cao; Chong-Huai Yan; Xiao-Dan Yu; Ying Tian; Xiang-Yu Zou; Da-Sheng Lu; Xiao-Ming Shen
Journal:  J Chromatogr Sci       Date:  2012-02       Impact factor: 1.618

7.  Ultrathin-shell boron nitride hollow spheres as sorbent for dispersive solid-phase extraction of polychlorinated biphenyls from environmental water samples.

Authors:  Meizhen Fu; Hanzhu Xing; Xiangfeng Chen; Fan Chen; Chi-Man Lawrence Wu; Rusong Zhao; Chuange Cheng
Journal:  J Chromatogr A       Date:  2014-10-07       Impact factor: 4.759

8.  Dispersive liquid-liquid microextraction combined with gas chromatography-electron capture detection for the determination of polychlorinated biphenyls in soils.

Authors:  Jia Hu; Lingyan Fu; Xinna Zhao; Xiujuan Liu; Huili Wang; Xuedong Wang; Liyan Dai
Journal:  Anal Chim Acta       Date:  2009-03-19       Impact factor: 6.558

9.  Determination of hydroxylated polychlorinated biphenyls by offline solid-phase extraction-liquid chromatography-tandem mass spectrometry using a molecularly imprinted polymer as a sorbent for sample preconcentration.

Authors:  Rongning Liang; Yan Zhao; Yang Su; Wei Qin
Journal:  Talanta       Date:  2015-05-28       Impact factor: 6.057

10.  Solid-phase extraction combined with dispersive liquid-liquid microextraction for the determination for polybrominated diphenyl ethers in different environmental matrices.

Authors:  Xiujuan Liu; Jianwang Li; Zhixu Zhao; Wei Zhang; Kuangfei Lin; Changjiang Huang; Xuedong Wang
Journal:  J Chromatogr A       Date:  2009-01-09       Impact factor: 4.759

View more
  1 in total

1.  Magnetic partially carbonized cellulose nanocrystal-based magnetic solid phase extraction for the analysis of triazine and triazole pesticides in water.

Authors:  Xiaotong Yi; Chang Liu; Xueke Liu; Peng Wang; Zhiqiang Zhou; Donghui Liu
Journal:  Mikrochim Acta       Date:  2019-11-21       Impact factor: 5.833

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.