Literature DB >> 22298765

Determination of polychlorinated biphenyls and organochlorine pesticides in human serum by gas chromatography with micro-electron capture detector.

Lu-Lu Cao1, Chong-Huai Yan, Xiao-Dan Yu, Ying Tian, Xiang-Yu Zou, Da-Sheng Lu, Xiao-Ming Shen.   

Abstract

A method for determination of concentrations of polychlorinated biphenyl congeners (PCB-28, 52, 101, 118, 138, 153, 156, and 187) and organochlorine pesticides (hexachlorobenzene, alpha-hexachlorocyclohexane, beta-hexachlorocyclohexane, gamma-hexachlorocyclohexane, delta-hexachlorocyclohexane, p,p'-dichlorodiphenyl dichloroethylene, o,p'-dichlorodiphenyl trichloroethane, p,p'-dichlorodiphenyl dichloroethane, p,p'-dichlorodiphenyl trichloroethane, alpha-chlordane, gamma-chlordane, heptachlor, heptachlor epoxide, and aldrin) in human serum is developed. Recovery is assessed with artificial serum, in which PCBs and OCPs could not be detected. The method is then confirmed with pooled human serum. Experiments are performed by adding two concentrations of analytes (0.5 µg/L and 1.0 µg/L) to both matrices. The sample pretreatment process involves denaturing with a mixture of water-1-propanol (v:v, 85:15), extraction with a C-18 cartridge, and cleanup with an Alumina B cartridge. This process required about 2 mL of serum. The limit of detection ranged from 0.05-0.35 µg/L for all the analytes. Recovery of analytes at low and high spiking concentrations varied from 63-122% and 61-124% for artificial serum and pooled human serum, respectively. Relative standard deviation was lower than 16% and 18% for artificial serum and pooled human serum, respectively. Stability of the method, expressed as relative standard deviation, was lower than 14%. The method has been applied in epidemiological research.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22298765     DOI: 10.1093/chromsci/bmr031

Source DB:  PubMed          Journal:  J Chromatogr Sci        ISSN: 0021-9665            Impact factor:   1.618


  2 in total

1.  Simultaneous extraction of 32 polychlorinated biphenyls by using magnetic carbon nanocomposite based dispersive microextraction, subsequent dispersive liquid-liquid microextraction with two miscible stripping solvents, and quantitation by GC-μECD.

Authors:  Najmeh Yazdanfar; Mojtaba Shamsipur; Mahnaz Ghambarian
Journal:  Mikrochim Acta       Date:  2019-02-15       Impact factor: 5.833

2.  Association between serum levels of adiponectin and polychlorinated biphenyls in Korean men and women.

Authors:  Jung-eun Lim; Sun Ha Jee
Journal:  Endocrine       Date:  2014-03-25       Impact factor: 3.633

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.