Literature DB >> 30739304

Impact of time in therapeutic range after left ventricular assist device placement: a comparison between thrombus and thrombus-free periods.

Julia C Lea1, Catherine K Floroff2, Amanda I Ingemi3, Gary R Zeevi4.   

Abstract

The association between time in therapeutic range (TTR) and clinical outcomes in patients with left ventricular assist devices (LVADs) on chronic warfarin therapy is not well understood. This study assessed TTR using the Rosendaal Method prior to suspected or confirmed pump thrombosis or ischemic stroke. Each patient served as their own control. Characteristics and TTR in 1, 2, and 3 months prior to thrombus (thrombus period) were compared to a thrombus-free period during 6 months to 3 months prior to thrombus (control period). There were 30 thrombus events observed in 25 patients for a rate of 0.06 events per LVAD day. Average TTR (target INR = 2-3) over 3 months for patients combined in both the thrombus and control time period was 53.4%. TTR (target INR = 2-3) was 11.4% lower 1 month prior to thrombus than the comparable month in the control period (p = 0.029). The TTR (target INR = 1.8-2.5) was 11.8% lower in the thrombus time period compared to the control time period 2 months prior to thrombus (p = 0.032). Our study found an increased risk of thrombosis with lower TTR in months leading up to thrombus compared to a thrombus-free period.

Entities:  

Keywords:  Left ventricular assist device; Pump thrombosis; Time in therapeutic range

Mesh:

Substances:

Year:  2019        PMID: 30739304     DOI: 10.1007/s11239-018-01800-x

Source DB:  PubMed          Journal:  J Thromb Thrombolysis        ISSN: 0929-5305            Impact factor:   2.300


  22 in total

1.  Assessment of long-term anticoagulation in patients with a continuous-flow left-ventricular assist device: a pilot study.

Authors:  Douglas Jennings; Jane McDonnell; Jessica Schillig
Journal:  J Thorac Cardiovasc Surg       Date:  2011-05-06       Impact factor: 5.209

2.  The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: executive summary.

Authors:  David Feldman; Salpy V Pamboukian; Jeffrey J Teuteberg; Emma Birks; Katherine Lietz; Stephanie A Moore; Jeffrey A Morgan; Francisco Arabia; Mary E Bauman; Hoger W Buchholz; Mario Deng; Marc L Dickstein; Aly El-Banayosy; Tonya Elliot; Daniel J Goldstein; Kathleen L Grady; Kylie Jones; Katarzyna Hryniewicz; Ranjit John; Annemarie Kaan; Shimon Kusne; Matthias Loebe; M Patricia Massicotte; Nader Moazami; Paul Mohacsi; Martha Mooney; Thomas Nelson; Francis Pagani; William Perry; Evgenij V Potapov; J Eduardo Rame; Stuart D Russell; Erik N Sorensen; Benjamin Sun; Martin Strueber; Abeel A Mangi; Michael G Petty; Joseph Rogers
Journal:  J Heart Lung Transplant       Date:  2013-02       Impact factor: 10.247

3.  Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device.

Authors:  James K Kirklin; David C Naftel; Robert L Kormos; Francis D Pagani; Susan L Myers; Lynne W Stevenson; Michael A Acker; Daniel L Goldstein; Scott C Silvestry; Carmelo A Milano; J T Baldwin; J Timothy Baldwin; Sean Pinney; J Eduardo Rame; Marissa A Miller
Journal:  J Heart Lung Transplant       Date:  2013-11-27       Impact factor: 10.247

4.  The vexing problem of thrombosis in long-term mechanical circulatory support.

Authors:  Mandeep R Mehra; Garrick C Stewart; Patricia A Uber
Journal:  J Heart Lung Transplant       Date:  2013-12-10       Impact factor: 10.247

5.  An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial.

Authors:  Samer S Najjar; Mark S Slaughter; Francis D Pagani; Randall C Starling; Edwin C McGee; Peter Eckman; Antone J Tatooles; Nader Moazami; Robert L Kormos; David R Hathaway; Kevin B Najarian; Geetha Bhat; Keith D Aaronson; Steven W Boyce
Journal:  J Heart Lung Transplant       Date:  2013-12-12       Impact factor: 10.247

6.  Algorithm for the diagnosis and management of suspected pump thrombus.

Authors:  Daniel J Goldstein; Ranjit John; Christopher Salerno; Scott Silvestry; Nader Moazami; Douglas Horstmanshof; Robert Adamson; Andrew Boyle; Mark Zucker; Joseph Rogers; Stuart Russell; James Long; Francis Pagani; Ulrich Jorde
Journal:  J Heart Lung Transplant       Date:  2013-07       Impact factor: 10.247

7.  Patient characteristics associated with oral anticoagulation control: results of the Veterans AffaiRs Study to Improve Anticoagulation (VARIA).

Authors:  A J Rose; E M Hylek; A Ozonoff; A S Ash; J I Reisman; D R Berlowitz
Journal:  J Thromb Haemost       Date:  2010-10       Impact factor: 5.824

8.  Individual time within target range in patients treated with vitamin K antagonists: main determinant of quality of anticoagulation and predictor of clinical outcome. A retrospective study of 2300 consecutive patients with venous thromboembolism.

Authors:  Nic J G M Veeger; Margriet Piersma-Wichers; Jan G P Tijssen; Hans L Hillege; Jan van der Meer
Journal:  Br J Haematol       Date:  2005-02       Impact factor: 6.998

9.  Risks of stroke and mortality associated with suboptimal anticoagulation in atrial fibrillation patients.

Authors:  A M Gallagher; E Setakis; J M Plumb; A Clemens; T-P van Staa
Journal:  Thromb Haemost       Date:  2011-09-08       Impact factor: 5.249

10.  Unexpected abrupt increase in left ventricular assist device thrombosis.

Authors:  Randall C Starling; Nader Moazami; Scott C Silvestry; Gregory Ewald; Joseph G Rogers; Carmelo A Milano; J Eduardo Rame; Michael A Acker; Eugene H Blackstone; John Ehrlinger; Lucy Thuita; Maria M Mountis; Edward G Soltesz; Bruce W Lytle; Nicholas G Smedira
Journal:  N Engl J Med       Date:  2013-11-27       Impact factor: 91.245

View more
  2 in total

1.  Time in Therapeutic Range Significantly Impacts Survival and Adverse Events in Destination Therapy Patients.

Authors:  Gregory P Macaluso; Francis D Pagani; Mark S Slaughter; Carmelo A Milano; Erika D Feller; Antone J Tatooles; Joseph G Rogers; Georg M Wieselthaler
Journal:  ASAIO J       Date:  2022-01-01       Impact factor: 2.872

2.  Gastrointestinal Bleeding Rates in Left Ventricular Assist Device Population Reduced with Octreotide Utilization.

Authors:  Tyler J Wilson; David A Baran; John M Herre; Chad M Cameron; Amin Yehya; Amanda I Ingemi
Journal:  ASAIO J       Date:  2021-09-01       Impact factor: 3.826

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.