Literature DB >> 30737852

Methods and considerations concerning cardiac output measurement in pregnant women: recommendations of the International Working Group on Maternal Hemodynamics.

R C Bijl1, H Valensise2,3, G P Novelli4, B Vasapollo3, I Wilkinson5, B Thilaganathan6, E J Stöhr7,8, C Lees9, C D van der Marel10, J M J Cornette1.   

Abstract

Cardiac output (CO), along with blood pressure and vascular resistance, is one of the most important parameters of maternal hemodynamic function. Substantial changes in CO occur in normal pregnancy and in most obstetric complications. With the development of several non-invasive techniques for the measurement of CO, there is a growing interest in the determination of this parameter in pregnancy. These techniques were initially developed for use in critical-care settings and were subsequently adopted in obstetrics, often without appropriate validation for use in pregnancy. In this article, methods and devices for the measurement of CO are described and compared, and recommendations are formulated for their use in pregnancy, with the aim of standardizing the assessment of CO and peripheral vascular resistance in clinical practice and research studies on maternal hemodynamics.
Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  cardiac MRI; cardiac output; impedance cardiography; inert-gas rebreathing technique; pregnancy; pulmonary artery catheter; pulse-contour analysis; transthoracic echocardiography

Mesh:

Year:  2019        PMID: 30737852     DOI: 10.1002/uog.20231

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  5 in total

1.  Accuracy and trending ability of finger plethysmographic cardiac output monitoring in late pregnancy.

Authors:  Paul Bonnin; Benjamin Constans; Alain Duhamel; Maéva Kyheng; Anne-Sophie Ducloy-Bouthors; Max Gonzalez Estevez; Benoit Tavernier; Alexandre Gaudet
Journal:  Can J Anaesth       Date:  2022-08-04       Impact factor: 6.713

2.  Evaluation of pulse wave transit time analysis for non-invasive cardiac output quantification in pregnant patients.

Authors:  Emmanuel Schneck; Pascal Drubel; Rainer Schürg; Melanie Markmann; Thomas Kohl; Michael Henrich; Michael Sander; Christian Koch
Journal:  Sci Rep       Date:  2020-02-05       Impact factor: 4.379

Review 3.  Maternal Low Volume Circulation Relates to Normotensive and Preeclamptic Fetal Growth Restriction.

Authors:  Wilfried Gyselaers; Christoph Lees
Journal:  Front Med (Lausanne)       Date:  2022-06-09

4.  Study protocol for a prospective cohort study to investigate Hemodynamic Adaptation to Pregnancy and Placenta-related Outcome: the HAPPO study.

Authors:  Rianne C Bijl; Jérôme M J Cornette; Annemien E van den Bosch; Johannes J Duvekot; Jeroen Molinger; Sten P Willemsen; Anton H J Koning; Jolien W Roos-Hesselink; Arie Franx; Régine P M Steegers-Theunissen; Maria P H Koster
Journal:  BMJ Open       Date:  2019-11-10       Impact factor: 2.692

5.  The physiological effect of early pregnancy on a woman's response to a submaximal cardiopulmonary exercise test.

Authors:  Rianne C Bijl; Jérôme M J Cornette; Kim van der Ham; Merle L de Zwart; Dinis Dos Reis Miranda; Régine P M Steegers-Theunissen; Arie Franx; Jeroen Molinger; M P H Wendy Koster
Journal:  Physiol Rep       Date:  2020-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.