Fracture of the polyethylene tibial post in the posterior-stabilized total knee prosthesis: arthrographic and CT arthrographic diagnosis.

Yung Hsu1, Chien-Hung Lin1, Ginger H F Shu2, Tsyh-Jyi Hsieh1, Clement Kuen-Huang Chen3.   

Abstract

Fracture of the polyethylene tibial post in the posterior-stabilized total knee prosthesis is often delayed in diagnosis due to its nonspecific symptoms and the radiolucent characteristic of polyethylene on conventional radiography. Therefore, the diagnosis is always established by arthroscopy. Notwithstanding recent advances in imaging modalities, we are presently aware of only two related case reports on MRI and even no reports about arthrographic or CT-arthrographic diagnosis of fractured tibial post. We hereby report a case of a 58-year-old female patient who developed recurrent knee pain during the third year after total knee arthroplasty. The displaced polyethylene tibial post was clearly outlined by administered contrast material in the posterior knee. Under the diagnosis of fracture of the tibial post, the patient underwent isolated replacement of the broken polyethylene insert. Her knee pain significantly improved after the operation.

Entities:  

Keywords:  CT arthrography; Posterior-stabilized design; Tibial post fracture; Total knee arthroplasty

Mesh:

Substances:

Year:  2019        PMID: 30729263     DOI: 10.1007/s00256-019-03173-5

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  17 in total

1.  Catastrophic polyethylene failure diagnosed with magnetic resonance imaging in a painful total knee arthroplasty.

Authors:  Gregory C Mallo; Scott J C Stanat; Jason A Jones; James D Capozzi; Jonathan S Luchs
Journal:  J Arthroplasty       Date:  2010-03-23       Impact factor: 4.757

2.  Anterior tibial post impingement in a posterior stabilized total knee arthroplasty.

Authors:  Guoan Li; Ramprasad Papannagari; Ephrat Most; Sang Eun Park; Todd Johnson; Linggawati Tanamal; Harry E Rubash
Journal:  J Orthop Res       Date:  2005-05       Impact factor: 3.494

Review 3.  Current concepts in knee replacement: features and imaging assessment.

Authors:  Hyojeong Mulcahy; Felix S Chew
Journal:  AJR Am J Roentgenol       Date:  2013-12       Impact factor: 3.959

4.  Isolated tibial polyethylene insert exchange outcomes after total knee arthroplasty.

Authors:  Seann E Willson; Michelle L Munro; Julie C Sandwell; Kace A Ezzet; Clifford W Colwell
Journal:  Clin Orthop Relat Res       Date:  2009-08-12       Impact factor: 4.176

5.  Fracture of a polyethylene tibial post in a Scorpio posterior-stabilized knee prosthesis.

Authors:  Hong Chul Lim; Ji Hoon Bae; Jin Ho Hwang; Seung Joo Kim; Ji Yeol Yoon
Journal:  Clin Orthop Surg       Date:  2009-05-27

Review 6.  How to treat a tibial post fracture in total knee arthroplasty? A systematic review.

Authors:  Paul F Lachiewicz
Journal:  Clin Orthop Relat Res       Date:  2010-10-21       Impact factor: 4.176

7.  Fracture of the polyethylene tibial post in a NexGen posterior-stabilized knee prosthesis.

Authors:  Yen-Shuo Chiu; Wei-Ming Chen; Ching-Kuei Huang; Chao-Ching Chiang; Tain-Hsiung Chen
Journal:  J Arthroplasty       Date:  2004-12       Impact factor: 4.757

8.  The outcome of rotating-platform total knee arthroplasty with cement at a minimum of ten years of follow-up.

Authors:  Jean-Noel A Argenson; Sebastien Parratte; Abdullah Ashour; Bertrand Saintmard; Jean-Manuel Aubaniac
Journal:  J Bone Joint Surg Am       Date:  2012-04-04       Impact factor: 5.284

9.  Fracture of the polyethylene tibial post in a posterior cruciate-substituting total knee arthroplasty mimicking patellar clunk syndrome: a report of 5 cases.

Authors:  David R Mauerhan
Journal:  J Arthroplasty       Date:  2003-10       Impact factor: 4.757

10.  Mid- term results of stryker® scorpio plus mobile bearing total knee arthroplasty.

Authors:  Hideo Kobayashi; Naoto Mitsugi; Yuichi Mochida; Naoya Taki; Yasushi Akamatsu; Masato Aratake; Hirohiko Ota; Katsushi Ishii; Kengo Harigane; Taichi Ideno; Tomoyuki Saito
Journal:  Sports Med Arthrosc Rehabil Ther Technol       Date:  2012-10-18
View more
  1 in total

1.  Multi-energy spectral photon-counting computed tomography (MARS) for detection of arthroplasty implant failure.

Authors:  Lawrence Chun Man Lau; Wayne Yuk Wai Lee; Anthony P H Butler; Alex I Chernoglazov; Kwong Yin Chung; Kevin Ki Wai Ho; James Griffith; Philip H Butler; Patrick Shu Hang Yung
Journal:  Sci Rep       Date:  2021-01-15       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.