Literature DB >> 30725230

Monitoring drug pharmacokinetics and immunologic biomarkers in dermal interstitial fluid using a microneedle patch.

Chandana Kolluru1, Mikayla Williams1, Jihee Stephanie Yeh2, Richard K Noel3, Jennifer Knaack2, Mark R Prausnitz4.   

Abstract

Minimally invasive point-of-care diagnostic devices are of great interest for rapid detection of biomarkers in diverse settings. Although blood is the most common source of biomarkers, interstitial fluid (ISF) is an alternate body fluid that does not clot or contain red blood cells that often complicate analysis. However, ISF is difficult to collect. In this study, we assessed the utility of a microneedle patch to sample microliter volumes of ISF in a simple and minimally invasive manner. We demonstrated the use of ISF collected in this way for therapeutic drug monitoring by showing similar vancomycin pharmacokinetic profiles in ISF and serum from rats. We also measured polio-specific neutralizing antibodies and anti-polio IgG in ISF similar to serum in rats immunized with polio vaccine. These studies demonstrate the potential utility of ISF collected by microneedle patch in therapeutic drug monitoring and immunodiagnostic applications.

Entities:  

Keywords:  Biomarker; Interstitial fluid; Microneedle patch; Polio specific antibodies; Therapeutic drug monitoring; Vancomycin

Mesh:

Substances:

Year:  2019        PMID: 30725230      PMCID: PMC6533066          DOI: 10.1007/s10544-019-0363-3

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  10 in total

1.  Sampling interstitial fluid from human skin using a microneedle patch.

Authors:  Pradnya P Samant; Megan M Niedzwiecki; Nicholas Raviele; Vilinh Tran; Juan Mena-Lapaix; Douglas I Walker; Eric I Felner; Dean P Jones; Gary W Miller; Mark R Prausnitz
Journal:  Sci Transl Med       Date:  2020-11-25       Impact factor: 17.956

2.  Gelatin Methacryloyl Microneedle Patches for Minimally Invasive Extraction of Skin Interstitial Fluid.

Authors:  Jixiang Zhu; Xingwu Zhou; Han-Jun Kim; Moyuan Qu; Xing Jiang; KangJu Lee; Li Ren; Qingzhi Wu; Canran Wang; Xunmin Zhu; Peyton Tebon; Shiming Zhang; Junmin Lee; Nureddin Ashammakhi; Samad Ahadian; Mehmet Remzi Dokmeci; Zhen Gu; Wujin Sun; Ali Khademhosseini
Journal:  Small       Date:  2020-02-26       Impact factor: 13.281

Review 3.  Microneedles for transdermal diagnostics: Recent advances and new horizons.

Authors:  Gui-Shi Liu; Yifei Kong; Yensheng Wang; Yunhan Luo; Xudong Fan; Xi Xie; Bo-Ru Yang; Mei X Wu
Journal:  Biomaterials       Date:  2019-12-26       Impact factor: 12.479

4.  Plasmonic Paper Microneedle Patch for On-Patch Detection of Molecules in Dermal Interstitial Fluid.

Authors:  Chandana Kolluru; Rohit Gupta; Qisheng Jiang; Mikayla Williams; Hamed Gholami Derami; Sisi Cao; Richard K Noel; Srikanth Singamaneni; Mark R Prausnitz
Journal:  ACS Sens       Date:  2019-05-22       Impact factor: 7.711

Review 5.  Small-volume detection: platform developments for clinically-relevant applications.

Authors:  Wei-Hsuan Sung; Yu-Ting Tsao; Ching-Ju Shen; Chia-Ying Tsai; Chao-Min Cheng
Journal:  J Nanobiotechnology       Date:  2021-04-21       Impact factor: 10.435

Review 6.  Microneedle-based bioassays.

Authors:  Jixiang Zhu; Xingwu Zhou; Alberto Libanori; Wujin Sun
Journal:  Nanoscale Adv       Date:  2020-09-18

7.  Wearable microneedle-based electrochemical aptamer biosensing for precision dosing of drugs with narrow therapeutic windows.

Authors:  Shuyu Lin; Xuanbing Cheng; Jialun Zhu; Bo Wang; David Jelinek; Yichao Zhao; Tsung-Yu Wu; Abraham Horrillo; Jiawei Tan; Justin Yeung; Wenzhong Yan; Sarah Forman; Hilary A Coller; Carlos Milla; Sam Emaminejad
Journal:  Sci Adv       Date:  2022-09-23       Impact factor: 14.957

Review 8.  Microneedle-based devices for point-of-care infectious disease diagnostics.

Authors:  Rachael V Dixon; Eldhose Skaria; Wing Man Lau; Philip Manning; Mark A Birch-Machin; S Moein Moghimi; Keng Wooi Ng
Journal:  Acta Pharm Sin B       Date:  2021-02-16       Impact factor: 11.413

9.  Enhanced extraction of skin interstitial fluid using a 3D printed device enabling tilted microneedle penetration.

Authors:  Sanha Kim; Min Suk Lee; Hee Seok Yang; Jae Hwan Jung
Journal:  Sci Rep       Date:  2021-07-07       Impact factor: 4.379

Review 10.  Non-invasive Approaches for the Diagnosis of Autoimmune/Autoinflammatory Skin Diseases-A Focus on Psoriasis and Lupus erythematosus.

Authors:  Anna Berekméri; Ana Tiganescu; Adewonuola A Alase; Edward Vital; Martin Stacey; Miriam Wittmann
Journal:  Front Immunol       Date:  2019-08-21       Impact factor: 8.786

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.