Literature DB >> 30707265

Development and strategy of reference materials for the DNA-based detection of genetically modified organisms.

Yuhua Wu1, Jun Li1, Xiaying Li2, Shanshan Zhai1, Hongfei Gao1, Yunjing Li1, Xiujie Zhang3, Gang Wu4.   

Abstract

The enforcement of GMO labeling regulations requires validated analytical methods and certified reference materials (CRMs). The early labeling regulations stipulated that the GMO content should be expressed as percentage, but did not specify what unit this percentage referred to. Two reference systems, using mass fraction and copy number ratio as measurement units, individually, are established for GMO analysis using different metrological traceability chains. Three types of CRMs, powder CRMs certified for mass fractions, genomic DNA CRMs, and plasmid DNA CRMs certified for copy number ratios, were developed for calibration and quality control. The type, certification, and measurement unit commutability of current GMO CRMs are presented and discussed in this paper. Both existing reference systems are facing a metrological challenge, although later EU regulations specified that the measurement unit of GMO content must be expressed in mass fraction and recommended to convert one unit into another by introducing a conversion factor, further efforts are required to explore which reference system is more metrologically sound. The determination of conversion factor per CRM batch is recommended to be based on the pure CRMs produced from pure GM materials, which is expected to be the best choice for calibration of PCR measurement results.

Entities:  

Keywords:  Copy number ratio; GMO; Mass fraction; Measurement unit; PCR; Reference materials

Mesh:

Substances:

Year:  2019        PMID: 30707265     DOI: 10.1007/s00216-019-01576-w

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

1.  Development and Validation of a New Robust Detection Method for Low-Content DNA Using ΔΔCq-Based Real-Time PCR with Optimized Standard Plasmids as a Control Sample.

Authors:  Keisuke Soga; Kosuke Nakamura; Tomohiro Egi; Jumpei Narushima; Satoko Yoshiba; Masahiro Kishine; Junichi Mano; Kazumi Kitta; Reona Takabatake; Norihito Shibata; Kazunari Kondo
Journal:  Anal Chem       Date:  2022-10-07       Impact factor: 8.008

2.  Collaborative Ring Trial of the Applicability of a Reference Plasmid DNA Calibrant in the Quantitative Analysis of GM Maize Event MON810.

Authors:  Yanan Meng; Shu Wang; Jinchao Guo; Litao Yang
Journal:  Foods       Date:  2022-05-24

3.  Design and storage stability of reference materials for microfluidic quantitative PCR-based equine gene doping tests.

Authors:  Teruaki Tozaki; Aoi Ohnuma; Mio Kikuchi; Taichiro Ishige; Hironaga Kakoi; Kei-Ichi Hirota; Kanichi Kusano; Shun-Ichi Nagata
Journal:  J Equine Sci       Date:  2021-12-28

4.  Digital PCR-Based Characterization of a g10evo-epsps Gene-Specific Matrix Reference Material for Its Food and Feed Detection.

Authors:  Xiaoyun Chen; Huiru Yu; Pengfei Wang; Cheng Peng; Xiaofu Wang; Xiaoli Xu; Junfeng Xu; Jingang Liang; Liang Li
Journal:  Foods       Date:  2022-06-25
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.