Literature DB >> 30693730

[Determination of 10 volatile N-nitrosamines in meat products by gas chromatography-tandem mass spectrometry].

Mengmeng Zhu1, Qun Ye2, Tingting Zhou1, Lutao Chen1, Luping Yu1, Bin Li1, Jinfeng Hu3, Min Zhou1.   

Abstract

A gas chromatography-tandem mass spectrometry (GC-MS/MS) method was established for the determination of 10 volatile N-nitrosamines in meat products. The meat samples were extracted by simultaneous distillation extraction (SDE), and then a cleanup step involving the frozen fat removal method was applied. The analytes were quantified by the external standard method in multiple reaction monitoring (MRM) mode. Under the optimized conditions, the correlation coefficients of the standard calibration curves were greater than 0.99 in the range of 1.00-1000 μg/L. The limits of detection (LODs, S/N=3) and limits of quantification (LOQs, S/N=10) were 0.01-0.02 μg/kg and 0.04-0.07 μg/kg, respectively. The average spiked recoveries of the 10 volatile N-nitrosamines were 74.8%-94.3% at spiked levels of LOQ level, 1.0 and 2.0 μg/kg,and the relative standard deviations were less than 8.3%. Six volatile N-nitrosamines (N-nitrosodimethylamine (NDMA), N-nitrosodiethylamine (NDEA), N-nitrosopyrrolidine (NPYR), N-nitrosopiperidine (NPIP), N-nitrosodibutylamine (NDBA) and N-nitrosodi-n-propylamine (NDPA)) were detected in different types of meat products, and each volatile N-nitrosamine in pickled meat products had the highest detection values. The developed method has the advantages of simplicity, sufficient extraction, high sensitivity, and low reagent dosage, in addition to proving suitable for the daily testing requirements of a large number of samples in the laboratory.

Entities:  

Keywords:  N-nitrosamines; freezing lipid filtration; gas chromatography-tandem mass spectrometry (GC-MS/MS); meat products; simultaneous distillation extraction (SDE)

Mesh:

Substances:

Year:  2019        PMID: 30693730     DOI: 10.3724/SP.J.1123.2018.09037

Source DB:  PubMed          Journal:  Se Pu        ISSN: 1000-8713


  2 in total

1.  Development of GC-MS/MS Method for Simultaneous Estimation of Four Nitrosoamine Genotoxic Impurities in Valsartan.

Authors:  Sambasiva Rao Tummala; Krishnamanjari Pawar Amgoth
Journal:  Turk J Pharm Sci       Date:  2022-08-31

2.  [Determination of nine N-nitrosamines in animal derived foods by QuEChERS-isotope dilution combined with gas chromatography-tandem mass spectrometry].

Authors:  Xiangyi Kong; Lili Zhuang; Enhua Fang; Peng Lin; Zilong Zheng; Xianghua Zheng; Dunming Xu
Journal:  Se Pu       Date:  2021-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.