Literature DB >> 30691668

Clinical application of radiation dose reduction at abdominal CT.

Toru Higaki1, Yuko Nakamura2, Wataru Fukumoto3, Yukiko Honda4, Fuminari Tatsugami5, Kazuo Awai6.   

Abstract

Report VII of the Board on Radiation Effects Research (BRER), in which the linear no-threshold hypothesis was applied, estimates the lifetime carcinogenesis risk from computed tomography (CT) as 0.34 to 1.30%. Other studies provided evidence for breaks in double-stranded lymphocyte DNA in human blood during CT examinations. Although it cannot be claimed that such DNA damage is a direct cause of carcinogenesis, it is important to reduce the radiation exposure of patients subjected to CT studies. Here we focus on techniques and clinical applications of abdominal reduced-dose CT. With automatic exposure control (AEC), the X-ray tube current can be optimized and the noise level maintained uniformly, regardless of the target size. Iterative reconstruction can reduce the image noise on scans acquired at reduced radiation doses. Use of these techniques helped to reduce radiation exposure at routine examinations by about 20-40%. We also discuss advanced imaging methods such as dynamic perfusion CT.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Abdomen; Computer-assisted; Image processing; Multidetector computed tomography; Noise; Radiation exposure

Mesh:

Year:  2018        PMID: 30691668     DOI: 10.1016/j.ejrad.2018.12.018

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  4 in total

1.  A comprehensive assessment of physical image quality of five different scanners for head CT imaging as clinically used at a single hospital centre-A phantom study.

Authors:  Patrizio Barca; Fabio Paolicchi; Giacomo Aringhieri; Federica Palmas; Daniela Marfisi; Maria Evelina Fantacci; Davide Caramella; Marco Giannelli
Journal:  PLoS One       Date:  2021-01-14       Impact factor: 3.240

2.  Utilisation of virtual non-contrast images and virtual mono-energetic images acquired from dual-layer spectral CT for renal cell carcinoma: image quality and radiation dose.

Authors:  Xiaoxiao Zhang; Gumuyang Zhang; Lili Xu; Xin Bai; Xiaomei Lu; Shenghui Yu; Hao Sun; Zhengyu Jin
Journal:  Insights Imaging       Date:  2022-01-24

3.  Low-dose abdominopelvic computed tomography in patients with lymphoma: An image quality and radiation dose reduction study.

Authors:  Sungjin Yoon; Kwai Han Yoo; So Hyun Park; Hawk Kim; Jae Hoon Lee; Jinny Park; Seong Ho Park; Hwa Jung Kim
Journal:  PLoS One       Date:  2022-08-11       Impact factor: 3.752

4.  An Individualized Contrast-Enhanced Liver Computed Tomography Imaging Protocol Based on Body Mass Index in 126 Patients Seen for Liver Cirrhosis.

Authors:  Jian Jiang; Maowei Zhang; Yuan Ji; Chunfeng Li; Xin Fang; Shuyuan Zhang; Wei Wang; Lijun Wang; Ailian Liu
Journal:  Med Sci Monit       Date:  2021-06-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.