Literature DB >> 30690786

Importance of locking plate positioning in proximal humeral fractures as predicted by computer simulations.

James W A Fletcher1,2, Markus Windolf1, R Geoff Richards1, Boyko Gueorguiev1, Jan Buschbaum1, Peter Varga1.   

Abstract

Multifragmented proximal humeral fractures frequently require operative fixation. The locking plates commonly used are often placed relative to the greater tuberosity, however no quantitative data exists regarding the effect of positional changes. The aim of the study was to establish the effects from variations in proximal-distal PHILOS humeral plate positioning on predicted fixation failure risk. Twenty-one left-sided low-density virtual humeri models were created with a simulation framework from CT data of elderly donors and osteotomized to mimic an unstable three-part malreduced AO/OTA 11-B3.2 fracture with medial comminution. A PHILOS plate with either four or six proximal screws was used for fixation. Both configurations were modelled with plate repositioning 2 and 4 mm distally and proximally to its baseline position. Applying a validated computational model, three physiological loading situations were simulated and fixation failure predicted using average strain around the proximal screws-an outcome established as a surrogate for cycles to failure. Varying the craniocaudal plate position affected the peri-implant strain for both four and six-screw configurations. Even though significant changes were seen only in the latter, all tests suggested that more proximal plate positioning results in decreased peri-screw strains whereas distalizing creates increases in strain. These results suggest that even a small distal PHILOS plate malpositioning may reduce fixation stability. Plate distalization increases the probability of being unable to insert all screws within the humeral head, which dramatically increases the forces acting on the remaining screws. Proximal plate shifting may be beneficial, especially for constructs employing calcar screws.
© 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  PHILOS plate; finite element analysis; fixation failure; plate positioning; proximal humerus fracture

Mesh:

Year:  2019        PMID: 30690786     DOI: 10.1002/jor.24235

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  13 in total

Review 1.  [Cement augmentation and bone graft substitutes-Materials and biomechanics].

Authors:  Boyko Gueorguiev; Mark Lenz
Journal:  Unfallchirurgie (Heidelb)       Date:  2022-04-29

2.  Role of Additional Inferomedial Supporting Screws in Osteoporotic 3-Part Proximal Humerus Fracture: Finite Element Analysis.

Authors:  Hyojune Kim; Wonhee Lee; SeungHyun Choi; Erica Kholinne; Euisop Lee; Wael Mohammed Alzahrani; Kyoung Hwan Koh; In-Ho Jeon; Shinseok Kim
Journal:  Geriatr Orthop Surg Rehabil       Date:  2020-11-04

3.  Cement augmentation of calcar screws may provide the greatest reduction in predicted screw cut-out risk for proximal humerus plating based on validated parametric computational modelling: Augmenting proximal humerus fracture plating.

Authors:  Peter Varga; Jason A Inzana; James W A Fletcher; Ladina Hofmann-Fliri; Armin Runer; Norbert P Südkamp; Markus Windolf
Journal:  Bone Joint Res       Date:  2020-09-03       Impact factor: 5.853

Review 4.  A review on computer-aided design and manufacturing of patient-specific maxillofacial implants.

Authors:  Afaque Rafique Memon; Enpeng Wang; Junlei Hu; Jan Egger; Xiaojun Chen
Journal:  Expert Rev Med Devices       Date:  2020-03-12       Impact factor: 3.166

5.  Generic Implant Positioning Technology Based on Hole Projections in X-Ray Images.

Authors:  Markus Windolf; Robert Geoff Richards
Journal:  J Med Device       Date:  2021-03-23       Impact factor: 0.743

6.  Development of three-dimensional preoperative planning system for the osteosynthesis of distal humerus fractures.

Authors:  Yuichi Yoshii; Shin Teramura; Kazuki Oyama; Takeshi Ogawa; Yuki Hara; Tomoo Ishii
Journal:  Biomed Eng Online       Date:  2020-07-13       Impact factor: 2.819

7.  PHILOS Plate Plus Oblique Insertion of Autologous Fibula for 2-Part Proximal Humerus Fractures With Medial Column Disruption: A Retrospective Study.

Authors:  Ying Shu; Meiji Chen; Weiguang Yu; Zhe Ge; Hao Hu; Xinchao Zhang; Xianshang Zeng; Xiangzhen Liu
Journal:  Geriatr Orthop Surg Rehabil       Date:  2021-03-04

8.  Why locking plates for the proximal humerus do not fit well.

Authors:  Hyungsuk Kim; Yang-Guk Chung; Ji Seok Jang; Yongdeok Kim; Soo Bin Park; Hyun Seok Song
Journal:  Arch Orthop Trauma Surg       Date:  2020-11-10       Impact factor: 3.067

Review 9.  Finite Element Analysis of Fracture Fixation.

Authors:  Gregory S Lewis; Dominic Mischler; Hwabok Wee; J Spence Reid; Peter Varga
Journal:  Curr Osteoporos Rep       Date:  2021-06-29       Impact factor: 5.163

10.  Comparison of locking plates and intramedullary nails in treatment of three-part or four-part proximal humeral neck fractures in elderly population: A randomized trial protocol.

Authors:  Hua Song; Mingming Wang; Hongyang Du; Weidong Mu
Journal:  Medicine (Baltimore)       Date:  2020-11-13       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.