Literature DB >> 30688961

Cell phone based colorimetric analysis for point-of-care settings.

Benjamin Coleman1, Chad Coarsey2, Waseem Asghar3.   

Abstract

Cell phones show considerable promise for point-of-care (POC) diagnostic procedures because they are accessible, connected, and computationally powerful. Cell phone image processing methods are being developed for the detection and quantification of a wide range of targets, employing methods from microscopy to fluorescence techniques. However, most of the lab-based biological and biochemical assays still lack a robust and repeatable cell phone analogue. Existing solutions require external smartphone hardware to obtain quantitative results, imposing a design tradeoff between accessibility and accuracy. Here, we develop a cell phone imaging algorithm that enables analysis of assays that would typically be evaluated via spectroscopy. The developed technique uses the saturation parameter of hue-saturation-value color space to enable POC diagnosis. Through the analysis of over 10 000 images, we show that the saturation method consistently outperforms existing algorithms under a wide range of operating field conditions. The performance improvement is also proven analytically via the mathematic relationship between the saturation method and existing techniques. The method presented here is a step forward towards the development of POC diagnostics by reducing the required equipment, improving the limit of detection (LOD), and increasing the precision of quantitative results.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30688961      PMCID: PMC6411445          DOI: 10.1039/c8an02521e

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  32 in total

1.  Integrated rapid-diagnostic-test reader platform on a cellphone.

Authors:  Onur Mudanyali; Stoyan Dimitrov; Uzair Sikora; Swati Padmanabhan; Isa Navruz; Aydogan Ozcan
Journal:  Lab Chip       Date:  2012-05-17       Impact factor: 6.799

2.  Requirements for high impact diagnostics in the developing world.

Authors:  Mickey Urdea; Laura A Penny; Stuart S Olmsted; Maria Y Giovanni; Peter Kaspar; Andrew Shepherd; Penny Wilson; Carol A Dahl; Steven Buchsbaum; Gerry Moeller; Deborah C Hay Burgess
Journal:  Nature       Date:  2006-11-23       Impact factor: 49.962

3.  Simple telemedicine for developing regions: camera phones and paper-based microfluidic devices for real-time, off-site diagnosis.

Authors:  Andres W Martinez; Scott T Phillips; Emanuel Carrilho; Samuel W Thomas; Hayat Sindi; George M Whitesides
Journal:  Anal Chem       Date:  2008-04-11       Impact factor: 6.986

4.  Integration of cell phone imaging with microchip ELISA to detect ovarian cancer HE4 biomarker in urine at the point-of-care.

Authors:  Shuqi Wang; Xiaohu Zhao; Imran Khimji; Ragip Akbas; Weiliang Qiu; Dale Edwards; Daniel W Cramer; Bin Ye; Utkan Demirci
Journal:  Lab Chip       Date:  2011-09-01       Impact factor: 6.799

5.  Quantum dot enabled detection of Escherichia coli using a cell-phone.

Authors:  Hongying Zhu; Uzair Sikora; Aydogan Ozcan
Journal:  Analyst       Date:  2012-03-07       Impact factor: 4.616

6.  Evaluation of a rapid and simple fourth-generation HIV screening assay for qualitative detection of HIV p24 antigen and/or antibodies to HIV-1 and HIV-2.

Authors:  G Beelaert; K Fransen
Journal:  J Virol Methods       Date:  2010-06-16       Impact factor: 2.014

7.  Shortening of the diagnostic window with a new combined HIV p24 antigen and anti-HIV-1/2/O screening test.

Authors:  S Brust; H Duttmann; J Feldner; L Gürtler; R Thorstensson; F Simon
Journal:  J Virol Methods       Date:  2000-11       Impact factor: 2.014

8.  Optofluidic fluorescent imaging cytometry on a cell phone.

Authors:  Hongying Zhu; Sam Mavandadi; Ahmet F Coskun; Oguzhan Yaglidere; Aydogan Ozcan
Journal:  Anal Chem       Date:  2011-08-02       Impact factor: 6.986

9.  Cost-effective and compact wide-field fluorescent imaging on a cell-phone.

Authors:  Hongying Zhu; Oguzhan Yaglidere; Ting-Wei Su; Derek Tseng; Aydogan Ozcan
Journal:  Lab Chip       Date:  2010-11-09       Impact factor: 6.799

10.  Assessment of the ability of a fourth-generation immunoassay for human immunodeficiency virus (HIV) antibody and p24 antigen to detect both acute and recent HIV infections in a high-risk setting.

Authors:  Mark W Pandori; John Hackett; Brian Louie; Ana Vallari; Teri Dowling; Sally Liska; Jeffrey D Klausner
Journal:  J Clin Microbiol       Date:  2009-06-17       Impact factor: 5.948

View more
  8 in total

1.  Smartphone-based sickle cell disease detection and monitoring for point-of-care settings.

Authors:  Shazia Ilyas; Mazhar Sher; E Du; Waseem Asghar
Journal:  Biosens Bioelectron       Date:  2020-07-09       Impact factor: 10.618

2.  Total Iron Measurement in Human Serum With a Novel Smartphone-Based Assay.

Authors:  Michael Serhan; David Jackemeyer; Mindy Long; Mark Sprowls; Ismael Diez Perez; Wolfgang Maret; Fang Chen; Nongjian Tao; Erica Forzani
Journal:  IEEE J Transl Eng Health Med       Date:  2020-06-26       Impact factor: 3.316

3.  Microfluidic Chip for Detection of Fungal Infections.

Authors:  Waseem Asghar; Mazhar Sher; Nida S Khan; Jatin M Vyas; Utkan Demirci
Journal:  ACS Omega       Date:  2019-04-24

4.  Development of a Flow-Free Magnetic Actuation Platform for an Automated Microfluidic ELISA.

Authors:  Chad Coarsey; Benjamin Coleman; Md Alamgir Kabir; Mazhar Sher; Waseem Asghar
Journal:  RSC Adv       Date:  2019-03-12       Impact factor: 4.036

5.  Enhancement of the Peroxidase-Like Activity of Iodine-Capped Gold Nanoparticles for the Colorimetric Detection of Biothiols.

Authors:  Chia-Chen Chang; Tsz-Lian Hsu; Chie-Pein Chen; Chen-Yu Chen
Journal:  Biosensors (Basel)       Date:  2020-09-01

6.  Assessment of a Smartphone-Based Loop-Mediated Isothermal Amplification Assay for Detection of SARS-CoV-2 and Influenza Viruses.

Authors:  Douglas M Heithoff; Lucien Barnes; Scott P Mahan; Gary N Fox; Katherine E Arn; Sarah J Ettinger; Andrew M Bishop; Lynn N Fitzgibbons; Jeffrey C Fried; David A Low; Charles E Samuel; Michael J Mahan
Journal:  JAMA Netw Open       Date:  2022-01-04

Review 7.  Smartphone-Based Multiplexed Biosensing Tools for Health Monitoring.

Authors:  Tutku Beduk; Duygu Beduk; Mohd Rahil Hasan; Emine Guler Celik; Jurgen Kosel; Jagriti Narang; Khaled Nabil Salama; Suna Timur
Journal:  Biosensors (Basel)       Date:  2022-07-29

8.  Development of a Flow-Free Automated Colorimetric Detection Assay Integrated with Smartphone for Zika NS1.

Authors:  Md Alamgir Kabir; Hussein Zilouchian; Mazhar Sher; Waseem Asghar
Journal:  Diagnostics (Basel)       Date:  2020-01-14
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.