| Literature DB >> 30685939 |
Chae Eun Yang1, Kwang Hyun Park1, Dong Won Lee1, Dae Hyun Lew1, Seung Yong Song1.
Abstract
BACKGROUND: Acellular dermal matrices (ADMs) have recently become widely used in breast reconstruction, but the correlation between the final expander volume and the surface area of the ADM is not well understood. In this study, the expansion of the surface area of ADM and the expander volume was studied retrospectively in cases of acellular dermis-assisted tissue expander breast reconstruction.Entities:
Keywords: Acellular dermis; Mammaplasty; Tissue expansion
Year: 2019 PMID: 30685939 PMCID: PMC6369041 DOI: 10.5999/aps.2018.00304
Source DB: PubMed Journal: Arch Plast Surg ISSN: 2234-6163
Summary of the dimensions of CGCryoDerm
| Size (cm) | Number |
|---|---|
| 4 × 15 | 3 |
| 4 × 16 | 2 |
| 4 × 17 | 1 |
| 5 × 12 | 2 |
| 5 × 14 | 3 |
| 5 × 15 | 4 |
| 6 × 12 | 2 |
| 6 × 14 | 1 |
| 6 × 15 | 1 |
| 6 × 17 | 1 |
| Total | 20 |
Summary of the tissue expanders used
| Type | Number |
|---|---|
| 133FV11 | 1 |
| 133FV12 | 4 |
| 133FV13 | 9 |
| 133FV14 | 1 |
| 133MV12 | 1 |
| 133MV13 | 4 |
| Total | 20 |
N-67-133FV11: 300 cm3, 11×11.5×5 (width [cm]×height [cm])×projection [cm]); N-67-133FV12: 400 cm3, 12×12.5×5.3; N-67-133FV13: 500 cm3, 13×13.5×5.7; N-67-133FV14: 600 cm3, 14×14.5×6.2; N-67-133MV12: 300 cm3, 12×11×5.2; N-67-133MV13: 400 cm3, 13× 12×5.6.
FV, full height/variable projection; MV, moderate height/variable projection.
Fig. 1.Measurements of ADM area
(A-C) The acellular dermal matrix (ADM) that was used. There was no folding or thinning of the ADM.
Fig. 2.Tissue expander with an ADM sling
Assuming that the tissue expander was round, we hypothesized that re (the radius of the acellular dermal matrix [ADM] area) and rv (radius of the tissue expander volume) would be equal. re and rv had equal dimensions, making it possible to compare them directly. (A) Conceptual image of round tissue expander and ADM. (B) Schema of how the proportional increases were compared.
Summary of tissue expander volume and ADM area
| Tissue expander (mL) | ADM (cm2) | |
|---|---|---|
| Measurements in the initial state | 116 (30–300) | 70.3 (60–102) |
| Measurements after final expansion | 402.5 (250–550) | 118.7 (65–185) |
Values are presented as average (range).
ADM, acellular dermal matrix.
Preoperative and postoperative calculated radii
| Tissue expander volume | ADM area | |
|---|---|---|
| Preoperative calculated radius (rpre-v & rpre-e, cm) | 4.62 (3.1–6.69) | 8.36 (7.74–10) |
| Postoperative calculated radius (rpost-v & rpost-e, cm) | 7.34 (6.12–8.2) | 10.8 (8.06–13.6) |
Values are presented as average (range).
ADM, acellular dermal matrix; re, radius of ADM area; rv, radius of the tissue expander volume.
Comparison of the proportional increase in the radii for ADM area and expander volume
| Tissue expander | ADM | |
|---|---|---|
| Proportional increase in the ratio | 1.1–2.24 | 1.04–1.34 |
| Mean value of the proportional increase | 1.66 | 1.28 |
We compared the proportional increase in the radius, assuming that the tissue expander was round. We calculated the proportional increase and the mean value thereof. We predicted that the proportional increases would be the same, but the proportional increase in the tissue expander radius was greater than that of the acellular dermal matrix (ADM) radius.