Literature DB >> 30685097

Paper microfluidic device for early diagnosis and prognosis of acute myocardial infarction via quantitative multiplex cardiac biomarker detection.

Wei Yin Lim1, T Malathi Thevarajah2, Boon Tong Goh3, Sook Mei Khor4.   

Abstract

The early detection of acute myocardial infarction (AMI) upon the onset of chest pain symptoms is crucial for patient survival. However, this detection is challenging, particularly without a persistent elevation of ST-segment reflected in an electrocardiogram or in blood tests. A majority of the available point-of-care testing devices allow accurate and rapid diagnosis of AMI. However, AMI diagnosis is reliable only at intermediate and later stages, with myocardial injury (> 6 h) and MI, based on the expression of specific cardiac biomarkers including troponin I or T (cTnI or cTnT), creatine kinase-MB (CK-MB), and myoglobin. Diagnosis at the early myocardial ischemia stage is not possible. To overcome this limitation, a sensitive and rapid microfluidic paper-based device (µPAD) was developed for the simultaneous detection of multiple cardiac biomarkers for the early and late diagnosis of AMI. The glycogen phosphorylase isoenzyme BB (GPBB) was detected during early (within first 4 h) ischemic myocardial injury. On the same µPAD platform, detection of prolonged elevation of levels of cTnT and CK-MB, which are only produced 6 h after the onset of chest pain in human serum, was possible. Sandwich immunoassay performed on the µPAD achieved reproducibility (RSD approximately 10% and intra-and inter-day precision (CV 10-20%, 99th percentile), as well as consistently stable test results for 28 days, with strong correlation (r2= 0.962), using the standard Siemens Centaur XPT Immunoassay system. The present findings indicate the potential of the µPAD platform as a point-of-care device for the early diagnosis and prognosis of AMI.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Acute myocardial infarction; Creatine kinase-MB; Glycogen phosphorylase isoenzyme BB; Microfluidic paper-based device; Multiplex detection; Troponin T

Mesh:

Substances:

Year:  2019        PMID: 30685097     DOI: 10.1016/j.bios.2018.12.049

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  12 in total

1.  Photoelectrochemical sandwich immunoassay of brain glycogen phosphorylase based on methyl orange-sensitized TiO2 nanorods.

Authors:  Chenglong Sun; Lu Li; Jialin Liu; Yun Du; Yueyi Peng; Qingji Xie
Journal:  Mikrochim Acta       Date:  2022-07-01       Impact factor: 6.408

2.  Patchouli alcohol protects against myocardial ischaemia-reperfusion injury by regulating the Notch1/Hes1 pathway.

Authors:  Ying Lu; Shou-Ye Li; Hui Lou
Journal:  Pharm Biol       Date:  2022-12       Impact factor: 3.889

3.  Potential molecular mechanism of ACE gene at different time points in STEMI patients based on genome-wide microarray dataset.

Authors:  Yao-Zong Guan; Rui-Xing Yin; Peng-Fei Zheng; Guo-Xiong Deng; Chun-Xiao Liu; Bi-Liu Wei
Journal:  Lipids Health Dis       Date:  2019-10-23       Impact factor: 3.876

Review 4.  Emerging point-of-care biosensors for rapid diagnosis of COVID-19: current progress, challenges, and future prospects.

Authors:  Yousef Rasmi; Xiaokang Li; Johra Khan; Tugba Ozer; Jane Ru Choi
Journal:  Anal Bioanal Chem       Date:  2021-05-18       Impact factor: 4.142

Review 5.  Nanotechnology for cardiovascular diseases.

Authors:  Qinqin Hu; Zheyan Fang; Junbo Ge; Hua Li
Journal:  Innovation (Camb)       Date:  2022-02-02

Review 6.  Recent Advances in Cardiac Tissue Engineering for the Management of Myocardium Infarction.

Authors:  Vineeta Sharma; Sanat Kumar Dash; Kavitha Govarthanan; Rekha Gahtori; Nidhi Negi; Mahmood Barani; Richa Tomar; Sudip Chakraborty; Santosh Mathapati; Dillip Kumar Bishi; Poonam Negi; Kamal Dua; Sachin Kumar Singh; Rohit Gundamaraju; Abhijit Dey; Janne Ruokolainen; Vijay Kumar Thakur; Kavindra Kumar Kesari; Niraj Kumar Jha; Piyush Kumar Gupta; Shreesh Ojha
Journal:  Cells       Date:  2021-09-25       Impact factor: 6.600

Review 7.  Microfluidic Point-of-Care (POC) Devices in Early Diagnosis: A Review of Opportunities and Challenges.

Authors:  Shih-Mo Yang; Shuangsong Lv; Wenjun Zhang; Yubao Cui
Journal:  Sensors (Basel)       Date:  2022-02-18       Impact factor: 3.576

Review 8.  Increasing the packing density of assays in paper-based microfluidic devices.

Authors:  Sajjad Rahmani Dabbagh; Elaina Becher; Fariba Ghaderinezhad; Hayati Havlucu; Oguzhan Ozcan; Mehmed Ozkan; Ali Kemal Yetisen; Savas Tasoglu
Journal:  Biomicrofluidics       Date:  2021-02-04       Impact factor: 2.800

Review 9.  Diagnostic accuracy of glycogen phosphorylase BB for myocardial infarction: A systematic review and meta-analysis.

Authors:  Anup Ghimire; Subarna Giri; Niharika Khanal; Shivani Rayamajhi; Anjila Thapa; Anil Bist; Surya Devkota
Journal:  J Clin Lab Anal       Date:  2022-03-24       Impact factor: 3.124

Review 10.  Advances in multiplex electrical and optical detection of biomarkers using microfluidic devices.

Authors:  Kaitlynn R Mitchell; Joule E Esene; Adam T Woolley
Journal:  Anal Bioanal Chem       Date:  2021-08-04       Impact factor: 4.142

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.