Literature DB >> 30684237

Validation of secondary dose calculation system with manufacturer-provided reference beam data using heterogeneous phantoms.

Yuji Nakaguchi1, Yuya Nakamura2, Yohei Yotsuji2.   

Abstract

The Mobius3D (M3D) system (Mobius Medical Systems) is a second-check dosimetry system. We investigated the dose calculation accuracy of this system using heterogeneous phantoms with reference beam data provided by the manufacturer using simple and patient plans. We compared the dose distributions between M3D and the treatment planning system, as well as the measurements in solid water phantoms, heterogeneous phantoms, and patient plans for Varian and Elekta accelerators. The M3D results agreed well with the measurements in the solid water phantoms for the simple plans. However, the accuracy of M3D appeared to depend on the type of accelerator, as indicated by the slight differences in the dose measurements. Furthermore, the M3D dose measurements differed by 5-10% in the lung and bone regions. Regarding the patient plans, we confirmed that M3D is reasonably accurate as a second-check system, despite the slight accelerator type-dependent dose difference.

Entities:  

Keywords:  Dose verification; Quality assurance; Reference beam data; Second-check dosimetry system; Volumetric modulated arc therapy

Mesh:

Year:  2019        PMID: 30684237     DOI: 10.1007/s12194-019-00499-6

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  9 in total

1.  Task Group 142 report: quality assurance of medical accelerators.

Authors:  Eric E Klein; Joseph Hanley; John Bayouth; Fang-Fang Yin; William Simon; Sean Dresser; Christopher Serago; Francisco Aguirre; Lijun Ma; Bijan Arjomandy; Chihray Liu; Carlos Sandin; Todd Holmes
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

2.  Monte Carlo-based correction factors for ion chamber dosimetry in heterogeneous phantoms for megavoltage photon beams.

Authors:  Fujio Araki
Journal:  Phys Med Biol       Date:  2012-10-26       Impact factor: 3.609

3.  Verification of monitor unit calculations for non-IMRT clinical radiotherapy: report of AAPM Task Group 114.

Authors:  Robin L Stern; Robert Heaton; Martin W Fraser; S Murty Goddu; Thomas H Kirby; Kwok Leung Lam; Andrea Molineu; Timothy C Zhu
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

4.  Accuracy of dose calculation algorithms for virtual heterogeneous phantoms and intensity-modulated radiation therapy in the head and neck.

Authors:  Ryota Onizuka; Fujio Araki; Takeshi Ohno; Yuji Nakaguchi; Yudai Kai; Yuuki Tomiyama; Kazunari Hioki
Journal:  Radiol Phys Technol       Date:  2016-01

5.  Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer.

Authors:  Yusuke Tsuruta; Manabu Nakata; Mitsuhiro Nakamura; Yukinori Matsuo; Kyoji Higashimura; Hajime Monzen; Takashi Mizowaki; Masahiro Hiraoka
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

6.  Validation of a modern second-check dosimetry system using a novel verification phantom.

Authors:  Daniel G McDonald; Dustin J Jacqmin; Christopher J Mart; Nicholas C Koch; Jean L Peng; Michael S Ashenafi; Mario A Fugal; Kenneth N Vanek
Journal:  J Appl Clin Med Phys       Date:  2017-01       Impact factor: 2.102

7.  Dosimetric validation and clinical implementation of two 3D dose verification systems for quality assurance in volumetric-modulated arc therapy techniques.

Authors:  Francisco Clemente-Gutiérrez; Consuelo Pérez-Vara
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

8.  Commissioning results of an automated treatment planning verification system.

Authors:  Christopher L Nelson; Bryan E Mason; Ronald C Robinson; Kelly D Kisling; Steven M Kirsner
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

9.  Evaluation of a novel secondary check tool for intensity-modulated radiotherapy treatment planning.

Authors:  Jonas D Fontenot
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

  9 in total
  1 in total

1.  Validation of a secondary dose check tool against Monte Carlo and analytical clinical dose calculation algorithms in VMAT.

Authors:  Stefano Piffer; Marta Casati; Livia Marrazzo; Chiara Arilli; Silvia Calusi; Isacco Desideri; Franco Fusi; Stefania Pallotta; Cinzia Talamonti
Journal:  J Appl Clin Med Phys       Date:  2021-03-18       Impact factor: 2.102

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.