Effect of combining electrocardiographic interpretation results on diagnostic accuracy.

J L Willems1, C Abreu-Lima, P Arnaud, J H van Bemmel, C Brohet, R Degani, B Denis, I Graham, G van Herpen, P W Macfarlane.   

Abstract

In order to test the diagnostic performance of various ECG computer programs a reference library of ECGs is being established and evaluation methods are being developed in an international co-operative project. A pilot study was undertaken in which 250 validated electrocardiograms (ECG) and vectorcardiograms (VCG) comprising seven diagnostic groups i.e., normal, left, right and bi-ventricular hypertrophy, anterior, inferior and combined infarction have been analysed independently by 11 different computer programs as well as by six cardiologists. A coding scheme was applied to assign individual diagnostic statements to a common set and to obtain combined program and cardiologist interpretation results. Preliminary results indicate that the accuracy of classification by different programs varies widely. Total accuracy varied between 57.2% and 75.8% (median 69.4%). The cardiologists had a higher accuracy (median 74.3%) than the majority of programs, at least when using the standard ECG. As it is considered premature to stress individual program results, in view of the current sample size, the enhancement in diagnostic accuracy obtained by combining interpretation results is highlighted. Indeed combined cardiologist and program results demonstrated the highest accuracy i.e., respectively 78.7% and 76.1%, higher than the result of any individual reader or program. The combined result of the five most accurate programs was 78.4%, that of the six least accurate was 71.5%, which is again higher than the respective individual components. These findings demonstrate that the combination of expert knowledge of computer programs can, similar to panel review and group analysis in clinical practice, enhance diagnostic accuracy.

Entities:  

Mesh:

Year:  1988        PMID: 3068061     DOI: 10.1093/oxfordjournals.eurheartj.a062453

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  2 in total

1.  Computer-assisted test interpretation: considerations in patient care.

Authors:  S D Hillson; D P Connelly
Journal:  J Med Syst       Date:  1992-10       Impact factor: 4.460

2.  Computer Interpretations of ECGs in Rural Hospitals: Determining the accuracy of interpretation.

Authors:  J M Thompson
Journal:  Can Fam Physician       Date:  1992-07       Impact factor: 3.275

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.