Literature DB >> 30676121

Mechanical properties and performances of contemporary drug-eluting stent: focus on the metallic backbone.

Ply Chichareon1,2, Yuki Katagiri1, Taku Asano1, Kuniaki Takahashi1, Norihiro Kogame1, Rodrigo Modolo1,3, Erhan Tenekecioglu4, Chun-Chin Chang4, Mariusz Tomaniak4,5, Neville Kukreja6, Joanna J Wykrzykowska1, Jan J Piek1, Patrick W Serruys7, Yoshinobu Onuma4.   

Abstract

INTRODUCTION: Drug-eluting stents (DES) are still the standard of care in percutaneous coronary intervention (PCI) since the fall of bioresorbable scaffolds with respect to safety. The unbeatable advantage of a metallic stent when compared with a scaffold is a stronger mechanical property and more sustainable vascular support. Recent development of contemporary metallic stent has focused on the reduction of strut thickness. However, there will always be a trade-off between improvement in deliverability, flexibility, and radial strength. AREAS COVERED: This review aims to discuss the designs of metallic stent platform and mechanical properties as well as mechanical performance of contemporary DES from bench studies and clinical trials. EXPERT OPINION: Mechanical properties of stents affect short- and long-term clinical outcomes. Ultrathin-strut DES have become popular and clinical trials have shown impressive results. Thinner struts may improve device flexibility and deliverability but the radial strength and longitudinal integrity might have been compromised as well. Ultrathin-strut cobalt chromium or platinum chromium DES will become standard of care in PCI practice in the near future. Information on the stent design, stent material and mechanical properties of the stent are essential for a rational selection of the appropriate stent in selected lesions and patients.

Entities:  

Keywords:  Mechanical properties; drug-eluting stent; longitudinal stent deformation; mechanical performance; radial strength; stent fracture; stent recoil

Mesh:

Substances:

Year:  2019        PMID: 30676121     DOI: 10.1080/17434440.2019.1573142

Source DB:  PubMed          Journal:  Expert Rev Med Devices        ISSN: 1743-4440            Impact factor:   3.166


  6 in total

Review 1.  Drug-eluting coronary stents: insights from preclinical and pathology studies.

Authors:  Sho Torii; Hiroyuki Jinnouchi; Atsushi Sakamoto; Matthew Kutyna; Anne Cornelissen; Salome Kuntz; Liang Guo; Hiroyoshi Mori; Emanuel Harari; Ka Hyun Paek; Raquel Fernandez; Diljon Chahal; Maria E Romero; Frank D Kolodgie; Anuj Gupta; Renu Virmani; Aloke V Finn
Journal:  Nat Rev Cardiol       Date:  2019-07-25       Impact factor: 32.419

2.  Serial invasive imaging follow-up of the first clinical experience with the Magmaris magnesium bioresorbable scaffold.

Authors:  Maria Natalia Tovar Forero; Laurens van Zandvoort; Kaneshka Masdjedi; Roberto Diletti; Jeroen Wilschut; Peter P de Jaegere; Felix Zijlstra; Nicolas M Van Mieghem; Joost Daemen
Journal:  Catheter Cardiovasc Interv       Date:  2019-04-29       Impact factor: 2.692

3.  Twelve-month clinical outcomes of sirolimus-eluting stent in coronary artery disease: An experience in real-world Indian patients.

Authors:  Srikanth Nathani; Asif Raheem; Harish Sanadhya; Prakash Chandra Purohit; Ramesh Patel; Praveen K Alane; Deepeshkumar Agarwal; Ramanand Sinha
Journal:  Anatol J Cardiol       Date:  2020-12       Impact factor: 1.596

Review 4.  Cardiovascular Stents: A Review of Past, Current, and Emerging Devices.

Authors:  Alexandru Scafa Udriște; Adelina-Gabriela Niculescu; Alexandru Mihai Grumezescu; Elisabeta Bădilă
Journal:  Materials (Basel)       Date:  2021-05-12       Impact factor: 3.623

5.  Evaluation of Mechanical Performances of Stents with 38 mm Length in Long Lesion.

Authors:  Xiaoting Yue; Jiacheng Guo; Jianchao Zhang; Chang Cao; Zenglei Zhang; Deliang Shen; Junnan Tang; Jinying Zhang
Journal:  Biomed Res Int       Date:  2020-02-27       Impact factor: 3.411

6.  Elastic stent recoil in coronary total occlusions: Comparison of durable-polymer zotarolimus eluting stent and ultrathin strut bioabsorbable-polymer sirolimus eluting stent.

Authors:  Riccardo Improta; Paola Scarparo; Jeroen Wilschut; Quinten Wolff; Joost Daemen; Wijnand K Den Dekker; Felix Zijlstra; Nicolas M Van Mieghem; Roberto Diletti
Journal:  Catheter Cardiovasc Interv       Date:  2021-05-07       Impact factor: 2.585

  6 in total