| Literature DB >> 30675531 |
Helen Razmjou1,2,3, Richard Holtby4,5.
Abstract
BACKGROUND: The primary purpose of this study was to explore the relationship between patient satisfaction and rotator cuff tendon reparability.Entities:
Keywords: Disability; Patient satisfaction; Repair; Rotator cuff; Tear size; Tendon reparability
Year: 2017 PMID: 30675531 PMCID: PMC6340829 DOI: 10.1016/j.jses.2017.03.003
Source DB: PubMed Journal: JSES Open Access ISSN: 2468-6026
Group differences in demographics and surgical findings
| Variable | Highly satisfied | Somewhat | A bit satisfied/dissatisfied | Statistics |
|---|---|---|---|---|
| Female: 65 | 53(82) | 10(15) | 2(3) | FET = 0.005 |
| Male: 80 | 54(68) | 18(23) | 8(10) | |
| 62(9) | 60(9) | 59(11) | F(2) = 0.96 | |
| Yes | 65(61) | 22(79) | 6(60) | FET = 0.01 |
| No | 42(79) | 6(21) | 4(40) | |
| Yes: 20 | 9(45) | 8(40) | 3(15) | FET = 0.001 |
| No: 125 | 98(78) | 20(16) | 7(6) | |
| Traumatic: 98 | 69(70) | 22(23) | 7(7) | FTE = 0.02 |
| Nontraumatic: 47 | 38(81) | 6(13) | 3(6) | |
| Massive: 12 | 6(50) | 4(33) | 2(17) | FTE = 0.001 |
| Large: 31 | 22(71) | 8(26) | 1(3) | |
| Small/moderate: 102 | 79(77) | 16(16) | 7(7) | |
| Partial: 23 | 12(52) | 10(44) | 1(4) | FTE = 0.001 |
| Full: 122 | 95(78) | 18(15) | 9(7) |
FET, Fisher exact test; SD, standard deviation.
Variables are presented as number(%) unless otherwise indicated.
Disability outcome measures (preoperative, postoperative, and change over time)
| Variable | Highly satisfied | Somewhat satisfied | Dissatisfied | Statistics (ANCOVA) |
|---|---|---|---|---|
| Preoperative ASES | 50 (18) | 50 (19) | 51 (16) | Preoperative: 9.25, |
| Postoperative ASES | 92 (10) | 71 (16) | 64 (17) | Satisfaction: 63.18, |
| Change | 43.10, | 21.01, | 12.67, | |
| Preoperative ShortWORC (0-100) | 39 (19) | 41 (20) | 33 (16) | Preoperative: 9.34, |
| Postoperative ShortWORC | 90 (16) | 61 (23) | 48 (16) | Satisfaction: 52.24, |
| Change | 50.56, | 19.82, | 14.57, | |
| Preoperative ACMS (0-100) | 40 (16) | 39 (19) | 33 (15) | Preoperative: 20.62, |
| Postoperative ACMS | 80 (12) | 61 (15) | 57 (14) | Satisfaction: 34.12, |
| Change | 39.94, | 22.03, | 24.40, | |
| Preoperative QuickDASH (0-100) | 46 (17) | 43 (16) | 51 (17) | Preoperative: 14.17, |
| Postoperative QuickDASH | 10 (14) | 29 (18) | 44 (16) | Satisfaction: 38.69, |
| Change | −36.11, | −13.60, | −7.72, | |
| Preoperative ROM (0-40) | 23 (8) | 20 (11) | 19 (8) | Preoperative: 13.23, |
| Postoperative ROM | 38 (9) | 32 (9) | 33 (8) | Satisfaction: 15.13, |
| Change | 15.01, | 10.92, | 13.60, | |
| Preoperative strength (lb) | 11 (10) | 16 (19) | 17 (9) | Preoperative: 0.39, |
| Postoperative strength (lb) | 12 (5) | 9 (5) | 8 (4) | Satisfaction: 6.97, |
| Change (lb) | 1 (11), | −8 (12), | −9 (9), |
SD, standard deviation; ANCOVA, analysis of covariance; ASES, American Shoulder and Elbow Surgeons; ACMS, absolute Constant-Murley score; QuickDASH, Quick Disabilities of the Arm, Shoulder, and Hand; ROM, range of motion; ShortWORC, short version of the Western Ontario Rotator Cuff index.
Variables are expressed as mean (standard deviation).