Christoph Kabbasch 1 , Lukas Goertz 2 , Eberhard Siebert 3 , Moriz Herzberg 4 , Jan Borggrefe 1 , Boris Krischek 2 , Pantelis Stavrinou 2 , Franziska Dorn 4 , Thomas Liebig 4 . Show Affiliations »
Abstract
BACKGROUND: Intrasaccular flow disruption represents a new paradigm in endovascular treatment of wide-necked bifurcation aneurysms. OBJECTIVE: To perform a matched case-control study comparing complications and angiographic outcome using the Woven Endobridge (WEB) device and stent-assisted coiling (SAC). METHODS: Sixty-six patients treated with the WEB at three German tertiary care centers were included and matched with 66 patients treated with SAC based on aneurysm location and unruptured/ruptured aneurysm status. Parameters were retrospectively analysed and compared between the treatment groups using inverse probability of treatment weighting (IPTW) with propensity scores. RESULTS: Procedural complication rates were 12.1% in the WEB group and 21.2% in the SAC group, which was statistically significant after IPTW adjustment (OR=2.2, 95% CI 1.08 to 4.4, p=0.03). Favourable outcome (modified Rankin scale score ≤2) was achieved by 57/66 (86.4%) in the WEB group and 57/66 (86.4%) in the SAC group (p=1.0). At mid-term follow-up, a similar number of aneurysms achieved adequate occlusion (complete occlusion or neck remnant) in the WEB group (93.9%) and in the SAC group (93.9%, p=1.0). Re-treatment was performed in 10.6% after WEB embolization and 12.1% after SAC (p=1.0). CONCLUSIONS: The WEB provides similar mid-term aneurysm occlusion rates to those of SAC, with no additional morbidity and potentially lower complication rates. Long-term outcome analysis will provide a definite conclusion on the use of WEB for intracranial aneurysms. © Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.
BACKGROUND: Intrasaccular flow disruption represents a new paradigm in endovascular treatment of wide-necked bifurcation aneurysms . OBJECTIVE: To perform a matched case-control study comparing complications and angiographic outcome using the Woven Endobridge (WEB) device and stent-assisted coiling (SAC). METHODS: Sixty-six patients treated with the WEB at three German tertiary care centers were included and matched with 66 patients treated with SAC based on aneurysm location and unruptured/ruptured aneurysm status. Parameters were retrospectively analysed and compared between the treatment groups using inverse probability of treatment weighting (IPTW ) with propensity scores. RESULTS: Procedural complication rates were 12.1% in the WEB group and 21.2% in the SAC group, which was statistically significant after IPTW adjustment (OR=2.2, 95% CI 1.08 to 4.4, p=0.03). Favourable outcome (modified Rankin scale score ≤2) was achieved by 57/66 (86.4%) in the WEB group and 57/66 (86.4%) in the SAC group (p=1.0). At mid-term follow-up, a similar number of aneurysms achieved adequate occlusion (complete occlusion or neck remnant) in the WEB group (93.9%) and in the SAC group (93.9%, p=1.0). Re-treatment was performed in 10.6% after WEB embolization and 12.1% after SAC (p=1.0). CONCLUSIONS: The WEB provides similar mid-term aneurysm occlusion rates to those of SAC, with no additional morbidity and potentially lower complication rates. Long-term outcome analysis will provide a definite conclusion on the use of WEB for intracranial aneurysms . © Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.
Entities: Chemical
Disease
Species
Keywords:
aneurysm; coil; device; statistics
Mesh: See more »
Year: 2019
PMID: 30674636 DOI: 10.1136/neurintsurg-2018-014555
Source DB: PubMed Journal: J Neurointerv Surg ISSN: 1759-8478 Impact factor: 5.836