Literature DB >> 30673939

Comparative Assessment of BGM and PLC/PRF/5 Cell Lines for Enteric Virus Detection in Biosolids.

Sherif Abd-Elmaksoud1,2, Nohelia Castro-Del Campo1,3, Charles P Gerba1, Ian L Pepper1, Kelly R Bright4.   

Abstract

The buffalo green monkey (BGM) cell line is required for the detection of enteric viruses in biosolids through a total culturable viral assay (TCVA) by the United States Environmental Protection Agency. In the present study, BGM and PLC/PRF/5 cell lines were evaluated for TCVA and for their use in determining the incidence of adenoviruses and enteroviruses in raw sludge and Class B biosolids. Six raw sludge and 17 Class B biosolid samples were collected from 13 wastewater treatment plants from seven U.S. states. Samples were processed via organic flocculation and concentrate volumes equivalent to 4 g total solids were assayed on BGM and PLC/PRF/5 cells. Cell monolayers were observed for cytopathic effect (CPE) after two 14-days passages. Cell lysates were tested for the presence of adenoviruses and enteroviruses by PCR or RT-PCR. The PLC/PRF/5 cells detected more culturable viruses than the BGM cells by CPE (73.9% vs. 56.5%, respectively). 52% of the samples were positive for CPE using both cell lines. No viruses were detected in either cell line by PCR in flasks in which CPE was not observed. No adenoviruses were detected in 13 CPE-positive samples from BGM lysates. In contrast, of the 17 samples exhibiting CPE on PLC/PRF/5 cells, 14 were positive for adenoviruses (82.4%). In conclusion, PLC/PRF/5 cells were superior for the detection of adenoviruses in both raw sludge and Class B biosolids. Thus, the use of BGM cells alone for TCVA may underestimate the viral concentration in sludge/biosolid samples.

Entities:  

Keywords:  Adenovirus; BGM cell line; Biosolids; Enteric viruses; ICC-PCR; PLC cell line

Mesh:

Substances:

Year:  2019        PMID: 30673939     DOI: 10.1007/s12560-019-09366-4

Source DB:  PubMed          Journal:  Food Environ Virol        ISSN: 1867-0334            Impact factor:   2.778


  24 in total

1.  Detection of astroviruses, enteroviruses, and adenovirus types 40 and 41 in surface waters collected and evaluated by the information collection rule and an integrated cell culture-nested PCR procedure.

Authors:  C D Chapron; N A Ballester; J H Fontaine; C N Frades; A B Margolin
Journal:  Appl Environ Microbiol       Date:  2000-06       Impact factor: 4.792

2.  A risk assessment of emerging pathogens of concern in the land application of biosolids.

Authors:  C P Gerba; I L Pepper; L F Whitehead
Journal:  Water Sci Technol       Date:  2002       Impact factor: 1.915

3.  Clearance of human-pathogenic viruses from sludge: study of four stabilization processes by real-time reverse transcription-PCR and cell culture.

Authors:  S Monpoeho; A Maul; C Bonnin; L Patria; S Ranarijaona; S Billaudel; V Ferré
Journal:  Appl Environ Microbiol       Date:  2004-09       Impact factor: 4.792

4.  Virus survival on inanimate surfaces.

Authors:  M C Mahl; C Sadler
Journal:  Can J Microbiol       Date:  1975-06       Impact factor: 2.419

5.  Occurrence and levels of indicators and selected pathogens in different sludges and biosolids.

Authors:  C Guzmán; J Jofre; M Montemayor; F Lucena
Journal:  J Appl Microbiol       Date:  2007-12       Impact factor: 3.772

6.  Comparison of BGM and PLC/PRC/5 cell lines for total culturable viral assay of treated sewage.

Authors:  Roberto A Rodríguez; Patricia M Gundy; Charles P Gerba
Journal:  Appl Environ Microbiol       Date:  2008-03-07       Impact factor: 4.792

7.  One-year survey of enteroviruses, adenoviruses, and reoviruses isolated from effluent at an activated-sludge purification plant.

Authors:  L G Irving; F A Smith
Journal:  Appl Environ Microbiol       Date:  1981-01       Impact factor: 4.792

8.  Decay of enteric microorganisms in biosolids-amended soil under wheat (Triticum aestivum) cultivation.

Authors:  K R Schwarz; J P S Sidhu; D L Pritchard; Y Li; S Toze
Journal:  Water Res       Date:  2014-04-04       Impact factor: 11.236

9.  Quantification of enteric viruses, pathogen indicators, and Salmonella bacteria in class B anaerobically digested biosolids by culture and molecular methods.

Authors:  Kelvin Wong; Brandon M Onan; Irene Xagoraraki
Journal:  Appl Environ Microbiol       Date:  2010-08-06       Impact factor: 4.792

10.  Survey of wastewater indicators and human pathogen genomes in biosolids produced by class a and class B stabilization treatments.

Authors:  Emily Viau; Jordan Peccia
Journal:  Appl Environ Microbiol       Date:  2008-11-07       Impact factor: 4.792

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.