Literature DB >> 30661880

Effect of layer thickness on the marginal and internal adaptation of laser-sintered metal frameworks.

Necati Kaleli1, Çağrı Ural2, Gözde Özköylü3, İbrahim Duran4.   

Abstract

STATEMENT OF PROBLEM: Laser sintering is commonly used for fabricating metal-ceramic restorations. The layer thickness of the sintering process may affect restoration adaptation. However, limited information is available regarding its impact.
PURPOSE: The purpose of this in vitro study was to compare the marginal and internal adaptation of laser-sintered cobalt-chromium single crown frameworks sintered with layer thicknesses of 25 and 50 μm.
MATERIAL AND METHODS: Thirty resin dies that represented prepared single molar abutment teeth were prepared by using a 3-dimensional printer and were divided into 3 groups (n=10) according to the method used for fabricating metal frameworks: group C, metal frameworks fabricated by using the lost-wax method (control); group L25, metal frameworks fabricated by using direct metal laser melting with a layer thickness of 25 μm; and group L50, metal frameworks fabricated by using direct metal laser melting with a layer thickness of 50 μm. After fabricating the metal frameworks, 15 vertical marginal discrepancy measurements were made in each axial region (mesial, distal, buccal, and lingual) using a stereomicroscope. Next, all the specimens were sectioned from the midline, and 5 internal discrepancy measurements were made in each internal region (inner marginal, axial, and occlusal). The data were analyzed statistically by using 1-way ANOVA, the Tukey honestly significant difference, and Tamhane T2 tests (α=.05).
RESULTS: The highest marginal and internal discrepancy values were obtained for metal frameworks in group C, and these values were significantly different (P<.001) from those obtained for metal frameworks in the other 2 groups. No significant difference was observed in the marginal and internal discrepancy values of metal frameworks in groups L25 and L50.
CONCLUSIONS: These results indicate that layer thickness does not affect the adaptation of laser-sintered metal frameworks, yet both sintering parameters yielded significantly lower mean marginal discrepancy values than the cast group.
Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30661880     DOI: 10.1016/j.prosdent.2018.08.018

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

Review 1.  Production time, effectiveness and costs of additive and subtractive computer-aided manufacturing (CAM) of implant prostheses: A systematic review.

Authors:  Sven Mühlemann; Jenni Hjerppe; Christoph H F Hämmerle; Daniel S Thoma
Journal:  Clin Oral Implants Res       Date:  2021-10       Impact factor: 5.021

2.  Evaluation of marginal discrepancy in metal frameworks fabricated by sintering-based computer-aided manufacturing methods.

Authors:  Necati Kaleli; Çağrı Ural; Yeşim Ölçer Us
Journal:  J Adv Prosthodont       Date:  2020-06-18       Impact factor: 1.904

3.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.