Literature DB >> 30661184

Impact of lens density and lens thickness on cumulative dissipated energy in femtosecond laser-assisted cataract surgery.

Mehdi Shajari1,2, Vladimir Rusev1, Wolfgang Mayer2, Vasilios Diakonis3, Kerstin Petermann1, Thomas Kohnen4.   

Abstract

To evaluate the required cumulative dissipated energy (CDE) to fragment the crystalline lens in femtosecond laser-assisted cataract surgery (FLACS) in relation to lens density and lens thickness. Consecutive eyes that underwent FLACS between September 2014 and March 2017 by a single surgeon using in all cases the same femtosecond laser and phacoemulsification platform were included in our retrospective study. Prior to surgery, corrected distance visual acuity (CDVA), optical biometry corneal, and crystalline lens tomographies were performed to assess anterior chamber depth (ACD), axial length (AL), and crystalline lens parameters (i.e., lens density, thickness, and nucleus staging (NS)). After surgery, CDE was calculated and analyzed in relation to lens density (LD) and lens thickness (LT). Zero ultrasound expenditure cases were recorded and their occurrence analyzed. The chart review identified 236 eyes of 200 patients, 98 males and 102 females aged 65± 15 years which were included in the study. Mean LD was 11.26 ± 2.05 pixel intensity units (range 7.30-18.80), and the mean LT was 3417 ± 405.17 μm (range 2545-4701). LD and LT correlated moderately (r = 0.50, p < 0.001) and weakly (r = 0.23, p < 0.001), with post-laser CDE. Higher LD and LT were also associated with lower rates of zero phaco (eyes in which no phacoemulsification energy was necessary). Furthermore, NS (r = 0.528, p < 0.001) and CDVA (r = - 0.3524, p < 0.001) also correlated with CDE. Higher LD, LT, NS values, and low CDVA are associated with higher ultrasound expenditure (CDE-cumulative dissipated energy) and with lower rates of zero ultrasound expenditure during FLACS.

Entities:  

Keywords:  CDE; Cataract surgery; Cumulative dissipated energy; FLACS; Femtosecond laser; Intraocular lens; Lens density; Lens thickness; Pentacam; Zero phaco

Mesh:

Year:  2019        PMID: 30661184     DOI: 10.1007/s10103-019-02715-6

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  3 in total

1.  Comparison of visual outcomes after bilateral implantation of two intraocular lenses with distinct diffractive optics.

Authors:  André Lins de Medeiros; Flavio Jones Saraiva; Camila Ishii Iguma; Danilo Varela Kniggendorf; Guilherme Alves; Mario Augusto Pereira Dias Chaves; Cesar Vilar; Antonio Francisco Pimenta Motta; Pedro Carlos Carricondo; Celso Takashi Nakano; Walton Nosé; Wilson Takashi Hida
Journal:  Clin Ophthalmol       Date:  2019-08-29

2.  An Assessment of Cataract Severity Based on Antioxidant Status and Ascorbic Acid Levels in Aqueous Humor.

Authors:  Yu-Ting Tsao; Wei-Chi Wu; Kuan-Jen Chen; Chun-Fu Liu; Yi-Jen Hsueh; Chao-Min Cheng; Hung-Chi Chen
Journal:  Antioxidants (Basel)       Date:  2022-02-16

3.  Correlation Between Degree of Lens Opacity and the Phacoemulsification Energy Parameters Using Different Imaging Methods in Age-Related Cataract.

Authors:  Li Feng; Fangkun Zhao; Xin Ke; Jiangyue Zhao; Mingyu Shi
Journal:  Transl Vis Sci Technol       Date:  2022-03-02       Impact factor: 3.283

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.