Evaluation of the correlation between prostatic displacement and rectal deformation using the Dice similarity coefficient of the rectum.

Yoshinori Tanabe1, Takayuki Ishida2, Hidetoshi Eto3, Tatsuhiro Sera3, Yuki Emoto3.   

Abstract

To estimate the relationship between the three-dimensional (3D) displacement error of the prostate and rectal deformation for reduction of deviation between the planned and treatment dose, using multiple acquisition planning CT (MPCT) and the Dice similarity coefficient (DSC) for rectal deformation for treatment of patients with prostate cancer. The 3D displacement error between the pelvic bone and a matching fiducial marker was calculated using MPCT in 24 patients who underwent prostate volumetric-modulated arc therapy for prostate cancer. We calculated the 3D displacement error between the pelvic bone and a matching fiducial marker on MPCT. The correlation of the 3D displacement error with the DSC of the rectum, calculated from MPCT images, was evaluated based on deformable image registration. The 3D displacement error of the prostate showed a slight correlation between MPCT and cone-beam computed tomography (adjusted r2 = 0.241). The 3D displacement error, based on the pelvic bone and a fiducial marker on MPCT images, showed a moderate correlation with the DSC of the rectum (adjusted r2 = 0.645) and was improved by a mean of 3.94 mm, based on MPCT, during the treatment period. The 3D displacement error on MPCT correlates with the 3D displacement error of daily cone-beam computed tomography; optimal selection of MPCT can potentially facilitate on-board setup of prostate patients to enable more accurate radiotherapy. The advance information of the 3D displacement error and rectal deformation is useful for optimal planning CT that can minimize the deviation between the planned dose and the treatment dose in patients receiving treatment for prostate cancer.
Copyright © 2018 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Deformable image registration; Dice similarity coefficient; Muscular layer tension; Prostate cancer; Volumetric-modulated arc therapy

Mesh:

Year:  2019        PMID: 30642696     DOI: 10.1016/j.meddos.2018.12.005

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  6 in total

1.  Prognostic and predictive value of radiomics features at MRI in nasopharyngeal carcinoma.

Authors:  Dan Bao; Yanfeng Zhao; Zhou Liu; Hongxia Zhong; Yayuan Geng; Meng Lin; Lin Li; Xinming Zhao; Dehong Luo
Journal:  Discov Oncol       Date:  2021-12-17

2.  Kidney Tumor Segmentation Based on FR2PAttU-Net Model.

Authors:  Peng Sun; Zengnan Mo; Fangrong Hu; Fang Liu; Taiping Mo; Yewei Zhang; Zhencheng Chen
Journal:  Front Oncol       Date:  2022-03-17       Impact factor: 6.244

3.  Development of a novel detection method for changes in lung conditions during radiotherapy using a temporal subtraction technique.

Authors:  Yoshinori Tanabe; Takayuki Ishida
Journal:  Phys Eng Sci Med       Date:  2021-10-26

4.  Prognostic and predictive value of radiomics features at MRI in nasopharyngeal carcinoma.

Authors:  Dan Bao; Yanfeng Zhao; Zhou Liu; Hongxia Zhong; Yayuan Geng; Meng Lin; Lin Li; Xinming Zhao; Dehong Luo
Journal:  Discov Oncol       Date:  2021-12-17

5.  Analysis of the Diagnosis Model of Peripheral Non-Small-Cell Lung Cancer under Computed Tomography Images.

Authors:  Zhonghai Xie; Huaizhong Zhang
Journal:  J Healthc Eng       Date:  2022-02-18       Impact factor: 2.682

6.  Statistical evaluation of the effectiveness of dual amplitude-gated stereotactic body radiotherapy using fiducial markers and lung volume.

Authors:  Yoshinori Tanabe; Hidekazu Tanaka
Journal:  Phys Imaging Radiat Oncol       Date:  2022-10-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.