Literature DB >> 30637847

Targeted rapid knee MRI exam using T2 shuffling.

Jonathan I Tamir1, Valentina Taviani2, Marcus T Alley3, Becki C Perkins4, Lori Hart4, Kendall O'Brien4, Fidaa Wishah3, Jesse K Sandberg3, Michael J Anderson5, Javier S Turek6, Theodore L Willke6, Michael Lustig1, Shreyas S Vasanawala3.   

Abstract

BACKGROUND: MRI is commonly used to evaluate pediatric musculoskeletal pathologies, but same-day/near-term scheduling and short exams remain challenges.
PURPOSE: To investigate the feasibility of a targeted rapid pediatric knee MRI exam, with the goal of reducing cost and enabling same-day MRI access. STUDY TYPE: A cost effectiveness study done prospectively.
SUBJECTS: Forty-seven pediatric patients. FIELD STRENGTH/SEQUENCE: 3T. The 10-minute protocol was based on T2 Shuffling, a four-dimensional acquisition and reconstruction of images with variable T2 contrast, and a T1 2D fast spin-echo (FSE) sequence. A distributed, compressed sensing-based reconstruction was implemented on a four-node high-performance compute cluster and integrated into the clinical workflow. ASSESSMENT: In an Institutional Review Board-approved study with informed consent/assent, we implemented a targeted pediatric knee MRI exam for assessing pediatric knee pain. Pediatric patients were subselected for the exam based on insurance plan and clinical indication. Over a 2-year period, 47 subjects were recruited for the study and 49 MRIs were ordered. Date and time information was recorded for MRI referral, registration, and completion. Image quality was assessed from 0 (nondiagnostic) to 5 (outstanding) by two readers, and consensus was subsequently reached. STATISTICAL TESTS: A Wilcoxon rank-sum test assessed the null hypothesis that the targeted exam times compared with conventional knee exam times were unchanged.
RESULTS: Of the 49 cases, 20 were completed on the same day as exam referral. Median time from registration to exam completion was 18.7 minutes. Median reconstruction time for T2 Shuffling was reduced from 18.9 minutes to 95 seconds using the distributed implementation. Technical fees charged for the targeted exam were one-third that of the routine clinical knee exam. No subject had to return for additional imaging. DATA
CONCLUSION: The targeted knee MRI exam is feasible and reduces the imaging time, cost, and barrier to same-day MRI access for pediatric patients. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2019.
© 2019 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  3D FSE; MR value; T2 shuffling; compressed sensing; rapid multicontrast imaging; turbo spin-echo (TSE)

Year:  2019        PMID: 30637847      PMCID: PMC6551292          DOI: 10.1002/jmri.26600

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  23 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Coil compression for accelerated imaging with Cartesian sampling.

Authors:  Tao Zhang; John M Pauly; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2012-04-09       Impact factor: 4.668

4.  Sparse MRI: The application of compressed sensing for rapid MR imaging.

Authors:  Michael Lustig; David Donoho; John M Pauly
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

5.  Homodyne detection in magnetic resonance imaging.

Authors:  D C Noll; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

Review 6.  MRI of the pediatric knee.

Authors:  Deepa R Pai; Peter J Strouse
Journal:  AJR Am J Roentgenol       Date:  2011-05       Impact factor: 3.959

Review 7.  Magnetic resonance imaging of the pediatric knee.

Authors:  Peter J Strouse; Khaldoun Koujok
Journal:  Top Magn Reson Imaging       Date:  2002-08

8.  Nonfatal sports- and recreation-related injuries treated in emergency departments--United States, July 2000-June 2001.

Authors: 
Journal:  MMWR Morb Mortal Wkly Rep       Date:  2002-08-23       Impact factor: 17.586

Review 9.  Pediatric musculoskeletal MRI: basic principles to optimize success.

Authors:  Diego Jaramillo; Tal Laor
Journal:  Pediatr Radiol       Date:  2007-11-29

10.  Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo.

Authors:  Reed F Busse; Anja C S Brau; Anthony Vu; Charles R Michelich; Ersin Bayram; Richard Kijowski; Scott B Reeder; Howard A Rowley
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

View more
  4 in total

1.  Computational MRI with Physics-based Constraints: Application to Multi-contrast and Quantitative Imaging.

Authors:  Jonathan I Tamir; Frank Ong; Suma Anand; Ekin Karasan; Ke Wang; Michael Lustig
Journal:  IEEE Signal Process Mag       Date:  2020-01-17       Impact factor: 12.551

2.  Echo planar time-resolved imaging with subspace reconstruction and optimized spatiotemporal encoding.

Authors:  Zijing Dong; Fuyixue Wang; Timothy G Reese; Berkin Bilgic; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2020-04-25       Impact factor: 4.668

3.  Scan-specific artifact reduction in k-space (SPARK) neural networks synergize with physics-based reconstruction to accelerate MRI.

Authors:  Yamin Arefeen; Onur Beker; Jaejin Cho; Heng Yu; Elfar Adalsteinsson; Berkin Bilgic
Journal:  Magn Reson Med       Date:  2021-10-02       Impact factor: 4.668

Review 4.  Rapid Knee MRI Acquisition and Analysis Techniques for Imaging Osteoarthritis.

Authors:  Akshay S Chaudhari; Feliks Kogan; Valentina Pedoia; Sharmila Majumdar; Garry E Gold; Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2019-11-21       Impact factor: 4.813

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.