Literature DB >> 30637512

A spherical metal-organic coordination polymer for the microextraction of neonicotinoid insecticides prior to their determination by HPLC.

Hui Ding1,2, Rongyu Wang1, Wei Liu1, Supan Cheng2, Wenhua Ji3, Zhenjia Zheng4, Xiao Wang5.   

Abstract

The authors describe a new spherical metal-organic coordination polymer (MOCP) for use as an adsorbent in solid-phase microextraction (SPME). By applying the ions Co(II), Fe(II), Cu(II), and Zn(II) in these polymers, MOCP with different morphology were obtained. The respective coatings for SPME display different extraction efficiency towards neonicotinoid insecticides (neo-nics). The Co(II)@MOCP coating displays an improved extraction capability for neo-nics when compared to the four commercially available coatings studied. Following extraction with the Co(II)@MOCP-coated fiber, the neo-nics were eluted using 1 mL of trifluoroacetic acid/acetonitrile solution and quantified by high performance liquid chromatography. The method, when applied to spiked honey samples, has good linearity (0.5-600 μg kg-1) and a low limit of detection (0.05-0.15 μg kg-1). The precision (n = 6) for a single fiber was in the range of 3.6-8.3%. The reproducibility (for n = 5) from fiber-to-fiber ranges between 5.4 and 8.8%. The Co(II)@MOCP-coated fiber can be reused more than 80 times without any apparent reduction in its performance. In addition, the relative recoveries from spiked honey samples are very good (91.5%-103.5%). Graphical abstract A spherical metal-organic coordination polymer (MOCP) was synthesized under the regulation of Co(II) and used for the solid-phase microextraction (SPME) of neonicotinoid insecticides found in honey.

Entities:  

Keywords:  Co(BF4)2; High performance liquid chromatography; Honey samples; Neonicotinoid pesticides; Solid-phase microextraction

Year:  2019        PMID: 30637512     DOI: 10.1007/s00604-018-3210-y

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  3 in total

1.  Monodisperse cobalt(II) based metal-organic coordination polymer beads as a sorbent for solid-phase extraction of chlorophenoxy acid herbicides prior to their quantitation by HPLC.

Authors:  Wenhua Ji; Hui Ding; Yanling Geng; Xiao Wang
Journal:  Mikrochim Acta       Date:  2019-11-11       Impact factor: 5.833

Review 2.  A comprehensive review on the pretreatment and detection methods of neonicotinoid insecticides in food and environmental samples.

Authors:  Yudan Wang; Yanwei Fu; Yunyun Wang; Qian Lu; Haonan Ruan; Jiaoyang Luo; Meihua Yang
Journal:  Food Chem X       Date:  2022-06-22

3.  Magnetic Solid Phase Extraction Based on Nanostructured Magnetic Porous Porphyrin Organic Polymer for Simultaneous Extraction and Preconcentration of Neonicotinoid Insecticides From Surface Water.

Authors:  Shirley K Selahle; Ngwako J Waleng; Anele Mpupa; Philiswa N Nomngongo
Journal:  Front Chem       Date:  2020-09-16       Impact factor: 5.221

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.