Literature DB >> 30625630

In-line monitoring of Ibuprofen during and after tablet compression using near-infrared spectroscopy.

Himmat Dalvi1, Alyssa Langlet2, Marie-Josee Colbert1, Antoine Cournoyer2, Jean-Maxime Guay2, Nicolas Abatzoglou1, Ryan Gosselin3.   

Abstract

Near infrared spectroscopy (NIRS) used as process analytical technology tool to monitor Active Pharmaceutical Ingredient concentrations during tablet manufacturing has been reported to enhance overall product quality assurance. NIRS applications in different manufacturing stages are facilitated by their ability to handle different sample presentations - be it solids, liquids, gels or powders. The present study evaluates NIRS suitability for monitoring Ibuprofen concentrations (coated pellets form) inside the feed frame of a tableting press as well as in output tablets. Process monitoring was undertaken with quantitative chemometric analysis. NIRS-based predictions of concentrations both inside the feed frame and in tablets were compared to ultraviolet (UV) spectroscopy assays of temporally stratified tablet samples. Process dynamics were also compared in terms of concurrent concentrations change kinetics in the feed frame and in output tablets. NIRS showed good sensitivity to Ibuprofen concentrations despite the use of coated pellets. Ibuprofen contents as low as 1.7% w/w were detected effectively. NIRS-based quantitative predictions in the feed frame and in tablets closely matched the UV assay values of sampled tablets. As anticipated from the 2-wheel feed frame geometry, upon the addition of each consecutive blend, results show that the predicted concentration inside the feed frame were delayed compared with that of the tablets exiting the tablet press. For these tests, the delay was estimated to be 1.25 min. This finding highlights the importance of NIRS probe position inside the feed frame as a function of its geometry. Successive feed frame and tablet monitoring by NIRS could prove beneficial for real time release testing of tablet formulations. Crown
Copyright © 2018. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chemometric analysis; Feed frame; NIRS; PAT; Real time release testing; Tablet

Mesh:

Substances:

Year:  2018        PMID: 30625630     DOI: 10.1016/j.talanta.2018.11.034

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

Review 1.  Pharmaceutical application of multivariate modelling techniques: a review on the manufacturing of tablets.

Authors:  Guolin Shi; Longfei Lin; Yuling Liu; Gongsen Chen; Yuting Luo; Yanqiu Wu; Hui Li
Journal:  RSC Adv       Date:  2021-02-23       Impact factor: 3.361

Review 2.  Process Analytical Technology Tools for Monitoring Pharmaceutical Unit Operations: A Control Strategy for Continuous Process Verification.

Authors:  Eun Ji Kim; Ji Hyeon Kim; Min-Soo Kim; Seong Hoon Jeong; Du Hyung Choi
Journal:  Pharmaceutics       Date:  2021-06-21       Impact factor: 6.321

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.