Chenxue Jiang1, Yun Chen1, Yaoyao Zhu1, Yapping Xu1. 1. Department of Radiation Oncology, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai 200433, China.
Abstract
BACKGROUND: We performed a systematic review and meta-analysis to assess the accuracy of 18F-fluorodeoxyglucose positron emission tomography with computer tomography (18F-FDG PET/CT) for detection of regional lymph node metastasis in esophageal squamous cell carcinoma in per-patient and per-nodal station basis. METHODS: Electronic databases were researched for studies assessing the sensitivity and specificity of PET/CT to detect the regional lymph node metastasis published between January 2006 and December 2017 on esophageal squamous cell carcinoma. STATA software was performed to assess the sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odd ratio (DOR) and summary receiver operating characteristic (SROC) curve. The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) and Deeks' Funnel Plot Asymmetry Test were performed to evaluate the study quality and publication bias of included studies. RESULTS: Nineteen studies were eligible for meta-analysis, comprising 1,089 patients with esophageal cancer who underwent 18F-FDG PET/CT before surgery. According to the content of the article, we divided the selected studies into per-patient basis group and per-nodal basis group (one of the articles was involved in both groups). For the per-nodal station basis group (12 studies, 5,681 stations), the pooled sensitivity and specificity estimates of 18F-FDG PET/CT for detecting regional lymph node metastasis were 66% [95% confidence interval (CI): 51-78%] and 96% (95% CI: 92-98%), respectively. The corresponding values on a per-patient basis group (8 studies; 506 patients) were 65% (95% CI: 49-78%) and 81% (95% CI: 69-89%) in sensitivity and specificity, respectively. CONCLUSIONS: Overall, 18F-FDG PET/CT have a moderate to low sensitivity and a high to moderate specificity for detection of regional nodal metastasis in esophageal cancer. Therefore, since the false rate is considerable, extending the extent of lymph node dissection or radiotherapy target volume is necessary after diagnosis of regional nodal metastasis by 18F-FDG PET/CT.
BACKGROUND: We performed a systematic review and meta-analysis to assess the accuracy of 18F-fluorodeoxyglucose positron emission tomography with computer tomography (18F-FDG PET/CT) for detection of regional lymph node metastasis in esophageal squamous cell carcinoma in per-patient and per-nodal station basis. METHODS: Electronic databases were researched for studies assessing the sensitivity and specificity of PET/CT to detect the regional lymph node metastasis published between January 2006 and December 2017 on esophageal squamous cell carcinoma. STATA software was performed to assess the sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odd ratio (DOR) and summary receiver operating characteristic (SROC) curve. The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) and Deeks' Funnel Plot Asymmetry Test were performed to evaluate the study quality and publication bias of included studies. RESULTS: Nineteen studies were eligible for meta-analysis, comprising 1,089 patients with esophageal cancer who underwent 18F-FDG PET/CT before surgery. According to the content of the article, we divided the selected studies into per-patient basis group and per-nodal basis group (one of the articles was involved in both groups). For the per-nodal station basis group (12 studies, 5,681 stations), the pooled sensitivity and specificity estimates of 18F-FDG PET/CT for detecting regional lymph node metastasis were 66% [95% confidence interval (CI): 51-78%] and 96% (95% CI: 92-98%), respectively. The corresponding values on a per-patient basis group (8 studies; 506 patients) were 65% (95% CI: 49-78%) and 81% (95% CI: 69-89%) in sensitivity and specificity, respectively. CONCLUSIONS: Overall, 18F-FDG PET/CT have a moderate to low sensitivity and a high to moderate specificity for detection of regional nodal metastasis in esophageal cancer. Therefore, since the false rate is considerable, extending the extent of lymph node dissection or radiotherapy target volume is necessary after diagnosis of regional nodal metastasis by 18F-FDG PET/CT.
Authors: Afina S Glas; Jeroen G Lijmer; Martin H Prins; Gouke J Bonsel; Patrick M M Bossuyt Journal: J Clin Epidemiol Date: 2003-11 Impact factor: 6.437
Authors: Liesbeth M Schreurs; Bareld B Pultrum; Klaas P Koopmans; Christian C Verhoef; Pieter L Jager; Gooitzen M Van Dam; Henk Groen; Erik J Van Der Jagt; John Th M Plukker Journal: Anticancer Res Date: 2008 May-Jun Impact factor: 2.480
Authors: Clemens Kratochwil; Paul Flechsig; Thomas Lindner; Labidi Abderrahim; Annette Altmann; Walter Mier; Sebastian Adeberg; Hendrik Rathke; Manuel Röhrich; Hauke Winter; Peter K Plinkert; Frederik Marme; Matthias Lang; Hans-Ulrich Kauczor; Dirk Jäger; Jürgen Debus; Uwe Haberkorn; Frederik L Giesel Journal: J Nucl Med Date: 2019-04-06 Impact factor: 10.057
Authors: Leonie R van der Werf; Elske Marra; Suzanne S Gisbertz; Bas P L Wijnhoven; Mark I van Berge Henegouwen Journal: Ann Surg Oncol Date: 2020-10-16 Impact factor: 5.344
Authors: Stefan Gabrielson; Jon A Tsai; Fuat Celebioglu; Magnus Nilsson; Ioannis Rouvelas; Mats Lindblad; Annie Bjäreback; Artur Tomson; Rimma Axelsson Journal: Nucl Med Commun Date: 2020-11 Impact factor: 1.698