Literature DB >> 30609595

Dual-channel ITO-microfluidic electrochemical immunosensor for simultaneous detection of two mycotoxins.

Lin Lu1, Sundaram Gunasekaran2.   

Abstract

Due to the widely occurring co-contamination of mycotoxins in raw food materials, simultaneous monitoring of multiple mycotoxins is needed. Herein, we report the design and fabrication of an electrochemical immunosensor for simultaneous detection of two mycotoxins, fumonisin B1 (FB1) and deoxynivalenol (DON), in a single test. A dual-channel three-electrode electrochemical sensor pattern was etched on a transparent indium tin oxide (ITO)-coated glass via photolithography and was integrated with capillary-driven polydimethylsiloxane (PDMS) microfluidic channel. The two working electrodes were functionalized with gold nanoparticles and anti-FB1 and anti-DON antibodies. Tests were performed by incubating the working electrodes in a sample solution introduced in the PDMS channel. The formation of toxin-antibody immunocomplexes on the working electrode surface produced electrochemical signal responses, which were recorded and compared with control signal to quantify individual mycotoxin concentrations. Using this dual-channel ITO-microfluidic electrochemical immunosensor we achieved limits of detection (LODs) of 97 pg/mL and 35 pg/mL, respectively for FB1 and DON, and their corresponding linear ranges of detection were 0.3-140 ppb and 0.2-60 ppb. The sensor performance, which remained stable for two weeks under proper storage, was validated by testing with ground corn extract used as a real food matrix.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Co-contamination; Immunosensor; Microfluidic; Mycotoxins; Photolithography

Mesh:

Substances:

Year:  2018        PMID: 30609595     DOI: 10.1016/j.talanta.2018.10.091

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  Simultaneous electrochemical determination of ochratoxin A and fumonisin B1 with an aptasensor based on the use of a Y-shaped DNA structure on gold nanorods.

Authors:  Min Wei; Lingkun Xin; Shuo Feng; Yong Liu
Journal:  Mikrochim Acta       Date:  2020-01-07       Impact factor: 5.833

Review 2.  Label-free electrochemical microfluidic biosensors: futuristic point-of-care analytical devices for monitoring diseases.

Authors:  Ghasem Ebrahimi; Parvin Samadi Pakchin; Amir Shamloo; Ali Mota; Miguel de la Guardia; Hossein Omidian; Yadollah Omidi
Journal:  Mikrochim Acta       Date:  2022-06-10       Impact factor: 5.833

Review 3.  Biosensors for the detection of respiratory viruses: A review.

Authors:  Brayan Viana Ribeiro; Taís Aparecida Reis Cordeiro; Guilherme Ramos Oliveira E Freitas; Lucas Franco Ferreira; Diego Leoni Franco
Journal:  Talanta Open       Date:  2020-08-16

Review 4.  Printed Electrodes in Microfluidic Arrays for Cancer Biomarker Protein Detection.

Authors:  Lasangi Dhanapala; Colleen E Krause; Abby L Jones; James F Rusling
Journal:  Biosensors (Basel)       Date:  2020-09-07

5.  Rapid, Sensitive On-Site Detection of Deoxynivalenol in Cereals Using Portable and Reusable Evanescent Wave Optofluidic Immunosensor.

Authors:  Yanping Liu; Yuyang Chen; Wenjuan Xu; Dan Song; Xiangzhi Han; Feng Long
Journal:  Int J Environ Res Public Health       Date:  2022-03-22       Impact factor: 3.390

Review 6.  Biosensors for Deoxynivalenol and Zearalenone Determination in Feed Quality Control.

Authors:  Krisztina Majer-Baranyi; Nóra Adányi; András Székács
Journal:  Toxins (Basel)       Date:  2021-07-17       Impact factor: 4.546

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.