Literature DB >> 30604650

The development of new image receptor-holding instruments with appropriate horizontal X-ray beam angulation for periapical radiographs.

Peerapong Wamasing1,2, Hiroshi Watanabe1, Yumi Tsuchida1, Naoto Ohbayashi1, Tetsuya Suzuki2, Tohru Kurabayashi1.   

Abstract

OBJECTIVES: This study aimed to develop new image receptor-holding instruments with appropriate horizontal X-ray beam angulation, based on the anatomical data of posterior region interproximal surfaces derived from archived CT images.
METHODS: CT images of 92 patients with sound upper and lower dental arches were collected from our CT database and analyzed to determine the angles between the tangential interproximal contact line and the central groove line of posterior teeth. The average angle for each site was calculated and used to modify instruments using a three-dimensional printer. The utilities of the conventional and the modified instruments for viewing proximal surfaces were compared using two dry skulls.
RESULTS: The right and left sides of each site, except for the lower second premolar and first molar sites, did not differ significantly. The difference between the sites was 2.0°; hence, we calculated mean values for the two sides at each site. In the maxilla, the angles of the first and second premolar, second premolar and first molar, and first and second molar to the groove line were 83.9° (±5.4°), 84.4° (±3.9°), 81.6° (±5.1°), while those in the mandible were 85.0° (±9.2°), 85.0° (±4.0°), and 90.6° (±4.9°), respectively. The holding instruments modified to 80° demonstrated better proximal viewing ability in the upper molar region than conventional instruments.
CONCLUSIONS: The mean angles of the interproximal surfaces were determined from CT data. The image receptor holding-instruments were modified according to these angles to allow appropriate X-ray angulation, which facilitated improved observation of the proximal surfaces of teeth in the posterior region in this pilot in vitro study.

Entities:  

Keywords:  X-ray beam; dental radiography; holding instruments; periapical radiograph

Mesh:

Year:  2019        PMID: 30604650      PMCID: PMC6592581          DOI: 10.1259/dmfr.20180354

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  5 in total

1.  The sensitivity, specificity, and reliability of radiographic periapical diagnosis of posterior teeth.

Authors:  R N Bohay
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2000-05

2.  Accuracy of radiographic assessment of interproximal bone loss in intrabony defects using linear measurements.

Authors:  P Eickholz; E Hausmann
Journal:  Eur J Oral Sci       Date:  2000-02       Impact factor: 2.612

3.  The effect of horizontal X-ray beam angulation on the detection of furcation defects of mandibular first molars in intraoral radiography.

Authors:  T Hishikawa; M Izumi; M Naitoh; M Furukawa; N Yoshinari; H Kawase; M Matsuoka; T Noguchi; E Ariji
Journal:  Dentomaxillofac Radiol       Date:  2010-02       Impact factor: 2.419

4.  Evaluation of x-ray projection angulation for successful radix entomolaris diagnosis in mandibular first molars in vitro.

Authors:  Qian Wang; Gang Yu; Xue-dong Zhou; Ove A Peters; Qing-hua Zheng; Ding-ming Huang
Journal:  J Endod       Date:  2011-08       Impact factor: 4.171

5.  A comparative study of radiographic quality with five periapical techniques in general dental practice.

Authors:  V E Rushton; K Horner
Journal:  Dentomaxillofac Radiol       Date:  1994-02       Impact factor: 2.419

  5 in total
  2 in total

1.  Reproducibility and diagnostic value of a new wedge-guided bitewing image receptor-holding device.

Authors:  Deivi Cascante-Sequeira; Hugo Gaêta-Araujo; Danieli Moura Brasil; Deborah Queiroz Freitas; Francisco Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2021-08-31       Impact factor: 2.419

2.  Development and validation of two new image receptor-holding devices for overlapping reduction of proximal surfaces in bitewing radiography: a preclinical study.

Authors:  Deivi Cascante-Sequeira; Hugo Gaêta-Araujo; Leonardo Vieira Peroni; Christiano Oliveira-Santos; Francisco Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2021-01-06       Impact factor: 2.419

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.