Literature DB >> 30602262

Development of a needle shaped microelectrode for electrochemical detection of the sepsis biomarker interleukin-6 (IL-6) in real time.

Christopher Russell1, Andrew C Ward2, Vincent Vezza2, Paul Hoskisson3, David Alcorn4, D Paul Steenson1, Damion K Corrigan5.   

Abstract

This paper outlines a simple label-free sensor system for the sensitive, real time measurement of an important protein biomarker of sepsis, using a novel microelectrode integrated onto a needle shaped substrate. Sepsis is a life threatening condition with a high mortality rate, which is characterised by dysregulation of the immune response following infection, leading to organ failure and cardiovascular collapse if untreated. Currently, sepsis testing is typically carried out by taking blood samples which are sent to a central laboratory for processing. Analysis times can be between 12 and 72 h making it notoriously difficult to diagnose and treat patients in a timely manner. The pathobiology of sepsis is becoming increasingly well understood and clinically relevant biomarkers are emerging, which could be used in conjunction with a biosensor to support real time diagnosis of sepsis. In this context, microelectrodes have the analytical advantages of reduced iR drop, enhanced signal to noise ratio, simplified quantification and the ability to measure in hydrodynamic situations, such as the bloodstream. In this study, arrays of eight (r = 25 µm) microelectrodes were fabricated onto needle shaped silicon substrates and electrochemically characterised in order to confirm successful sensor production and to verify whether the observed behaviour agreed with established theory. After this, the electrodes were functionalised with an antibody for interleukin-6 (IL-6) which is a protein involved in the immune response to infection and whose levels in the blood increase during progression of sepsis. The results show that IL-6 is detectable at physiologically relevant levels (pg/mL) with incubation times as short as 2.5 min. Electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) measurements were taken and DPV was concluded to be the more suitable form of measurement. In contrast to the accepted view for macro electrodes that the impedance increases upon antigen bind, we report herein a decrease in the micro electrode impedance upon binding. The small size of the fabricated devices and their needle shape make them ideal for either point of care testing or insertion into blood vessels for continuous sepsis monitoring.
Copyright © 2018. Published by Elsevier B.V.

Entities:  

Keywords:  Differential pulse voltammetry; Electrochemical impedance spectroscopy (EIS); Electrochemical sensors; Immunosensing; Microelectrodes

Mesh:

Substances:

Year:  2018        PMID: 30602262     DOI: 10.1016/j.bios.2018.11.053

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  24 in total

1.  Host-Response Subphenotypes Offer Prognostic Enrichment in Patients With or at Risk for Acute Respiratory Distress Syndrome.

Authors:  Georgios D Kitsios; Libing Yang; Dimitris V Manatakis; Mehdi Nouraie; John Evankovich; William Bain; Daniel G Dunlap; Faraaz Shah; Ian J Barbash; Sarah F Rapport; Yingze Zhang; Rebecca S DeSensi; Nathaniel M Weathington; Bill B Chen; Prabir Ray; Rama K Mallampalli; Panayiotis V Benos; Janet S Lee; Alison Morris; Bryan J McVerry
Journal:  Crit Care Med       Date:  2019-12       Impact factor: 7.598

Review 2.  Lubricin as a Therapeutic and Potential Biomarker in Sepsis.

Authors:  Holly Richendrfer; Gregory D Jay
Journal:  Crit Care Clin       Date:  2019-10-21       Impact factor: 3.598

Review 3.  Electrochemical biosensors for measurement of colorectal cancer biomarkers.

Authors:  Wenxian Zhang; Guangchun Xiao; Jun Chen; Li Wang; Qiongzheng Hu; Jian Wu; Wenhong Zhang; Ming Song; Jinwei Qiao; Chonghai Xu
Journal:  Anal Bioanal Chem       Date:  2021-03-05       Impact factor: 4.142

4.  Development of quantum dot-based fluorescence lateral flow immunoassay strip for rapid and quantitative detection of serum interleukin-6.

Authors:  Jinsong Tang; Lili Wu; Jingtao Lin; Erying Zhang; Yong Luo
Journal:  J Clin Lab Anal       Date:  2021-03-24       Impact factor: 2.352

Review 5.  Point-of-critical-care diagnostics for sepsis enabled by multiplexed micro and nanosensing technologies.

Authors:  Brandon K Ashley; Umer Hassan
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2021-03-01

Review 6.  Electroanalytical point-of-care detection of gold standard and emerging cardiac biomarkers for stratification and monitoring in intensive care medicine - a review.

Authors:  Robert D Crapnell; Nina C Dempsey; Evelyn Sigley; Ascanio Tridente; Craig E Banks
Journal:  Mikrochim Acta       Date:  2022-03-12       Impact factor: 6.408

7.  ADAR1 Alleviates Inflammation in a Murine Sepsis Model via the ADAR1-miR-30a-SOCS3 Axis.

Authors:  Zhou Shangxun; Li Junjie; Zhao Wei; Wang Yutong; Jia Wenyuan; Liu Shanshou; Wang Yanjun; Wang Qianmei; Feng Zhusheng; Yu Chaoping; Zhuang Ran; Yin Wen; Huang Yang
Journal:  Mediators Inflamm       Date:  2020-03-24       Impact factor: 4.711

Review 8.  Biomarkers for Point-of-Care Diagnosis of Sepsis.

Authors:  Andrew Teggert; Harish Datta; Zulfiqur Ali
Journal:  Micromachines (Basel)       Date:  2020-03-10       Impact factor: 2.891

9.  Establishing a Field-Effect Transistor Sensor for the Detection of Mutations in the Tumour Protein 53 Gene (TP53)-An Electrochemical Optimisation Approach.

Authors:  Lisa Crossley; Bukola Attoye; Vincent Vezza; Ewen Blair; Damion K Corrigan; Stuart Hannah
Journal:  Biosensors (Basel)       Date:  2019-12-06

Review 10.  Recent Advances in Electrochemical and Optical Biosensors Designed for Detection of Interleukin 6.

Authors:  Munezza Ata Khan; Mohammad Mujahid
Journal:  Sensors (Basel)       Date:  2020-01-23       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.