Literature DB >> 30591248

Vortex-assisted deep eutectic solvent reversed-phase liquid-liquid microextraction of triazine herbicides in edible vegetable oils.

Huazi Wang1, Xiaodong Huang2, Heng Qian1, Runhua Lu1, Sanbing Zhang1, Wenfeng Zhou1, Haixiang Gao3, Donghui Xu4.   

Abstract

In this study, four triazine herbicides-namely, simazine, ametryn, prometryn and terbuthylazine-were separated and determined using high-performance liquid chromatography coupled with ultraviolet detector (HPLC-UVD). The deep eutectic solvent (DES) formed by tetrabutylammonium chloride ([N4444]Cl, TBA) and ethylene glycol (EG) was selected as the extraction solvent of vortex-assisted reversed-phase liquid-liquid microextraction (VA-RPLLME). The application of the hydrophilic DES expands the range of choice for LLME. The experimental parameters affecting the extraction recoveries, including the amount of the DES, the sample volume and the vortex time, were investigated and optimized by the design of experiments (DoE) methodology. A quadratic model, namely central composite face-centered (CCF) design featuring 20 runs was used instead of the conventional trial and error approach. Under optimum conditions, the limits of determination (LODs) of the method were 0.60-1.50 μg L-1. The enrichment factors for the analytes ranged from 27 to 31. The extraction recoveries were in the range of 84.1-104.9%, and the intra-day, inter-day and intermediate relative standard deviations (RSDs) were less than 8.4%. Finally, the method was applied for the determination of triazine herbicides in vegetable oil samples. The obtained recoveries were in the range of 60.1-107.2% and RSDs were lower than 8.1%. In general, VA-RPLLME can be complementary to the present available methods for the determination of triazine herbicides in vegetable oil samples.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Deep eutectic solvent; Edible vegetable oils; Triazine herbicides; Vortex-assisted liquid–liquid microextraction

Mesh:

Substances:

Year:  2018        PMID: 30591248     DOI: 10.1016/j.chroma.2018.12.049

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Deep eutectic solvent-based liquid-phase microextraction coupled with reversed-phase high-performance liquid chromatography for determination of α-, β-, γ-, and δ-tocopherol in edible oils.

Authors:  Qilong Xie; Ming Xia; Dekui Sun; Jiangping Cao; Yong Xiao; Mingui Lin; Bo Hou; Litao Jia; Debao Li
Journal:  Anal Bioanal Chem       Date:  2020-11-18       Impact factor: 4.142

2.  Deep eutectic solvent-based emulsification liquid-liquid microextraction for the analysis of phenoxy acid herbicides in paddy field water samples.

Authors:  Nur 'An Nisaa Mohamad Yusoff; Nurul Yani Rahim; Rania Edrees Adam Mohammad; Noorfatimah Yahaya; Mazidatulakmam Miskam
Journal:  R Soc Open Sci       Date:  2021-03-31       Impact factor: 2.963

Review 3.  Application of Deep Eutectic Solvents in Food Analysis: A Review.

Authors:  Jingnan Chen; Yun Li; Xiaoping Wang; Wei Liu
Journal:  Molecules       Date:  2019-12-16       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.