Literature DB >> 3058769

Ultrasonic backscatter from flowing whole blood. II: Dependence on frequency and fibrinogen concentration.

Y W Yuan1, K K Shung.   

Abstract

Earlier studies showed that ultrasonic backscatter from erythrocytes suspended in saline is a function of hematocrit and frequency and that it can be affected by flow disturbance. The experimental data agree well with the theories. Recently, studies have been extended to flowing whole blood. The results indicated that ultrasonic backscatter from flowing whole blood differs from that from saline suspensions of erythrocytes in that it is shear-rate dependent and species dependent. In the present article, data on the dependence of ultrasonic backscatter from flowing whole blood on frequency and on fibrinogen concentration are reported. It was found that ultrasonic backscatter from flowing whole blood also depends on fibrinogen concentration when red blood cell (RBC) aggregation exists. Moreover, when the blood is under conditions that favor RBC aggregation such as low shear rates, high fibrinogen concentration, or high hematocrits, Rayleigh scattering apparently is no longer sufficient to describe its scattering behavior.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3058769     DOI: 10.1121/1.396620

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  6 in total

1.  A system-based approach to modeling the ultrasound signal backscattered by red blood cells.

Authors:  I Fontaine; M Bertrand; G Cloutier
Journal:  Biophys J       Date:  1999-11       Impact factor: 4.033

2.  Rheology and ultrasound scattering from aggregated red cell suspensions in shear flow.

Authors:  L Haider; P Snabre; M Boynard
Journal:  Biophys J       Date:  2004-10       Impact factor: 4.033

3.  Assessment of accuracy of the structure-factor-size-estimator method in determining red blood cell aggregate size from ultrasound spectral backscatter coefficient.

Authors:  Ratan K Saha; Emilie Franceschini; Guy Cloutier
Journal:  J Acoust Soc Am       Date:  2011-04       Impact factor: 1.840

4.  High levels of high sensitivity C-reactive protein predict the progression of chronic rheumatic mitral stenosis.

Authors:  Omer Alyan; Fatma Metin; Fehmi Kacmaz; Ozcan Ozdemir; Orhan Maden; Serkan Topaloglu; Ahmet Duran Demir; Zulkuf Karahan; Aziz Karadede; Erdogan Ilkay
Journal:  J Thromb Thrombolysis       Date:  2008-07-12       Impact factor: 2.300

Review 5.  Review of Quantitative Ultrasound: Envelope Statistics and Backscatter Coefficient Imaging and Contributions to Diagnostic Ultrasound.

Authors:  Michael L Oelze; Jonathan Mamou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-01-08       Impact factor: 2.725

6.  Predictive factors of left atrial spontaneous echo contrast in patients with rheumatic mitral valve stenosis: a retrospective study of 159 patients.

Authors:  Sanaa Drissi; Hicham Sabor; Ahlam Ounsy; Najat Mouine; Mohamed Sabry; Aatif Benyass; El Mehdi Zbir; Konate Lassana; Naima Elhaithem
Journal:  Int Arch Med       Date:  2014-06-25
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.