Literature DB >> 30586207

Computational Study of the Effect of Electrode Polarity on Neural Activation Related to Paresthesia Coverage in Spinal Cord Stimulation Therapy.

Jose L Durá1, Carmen Solanes1, Jose De Andrés2,3, Javier Saiz1.   

Abstract

OBJECTIVE: Using computer simulation, we investigated the effect of electrode polarity on neural activation in spinal cord stimulation and propose a new strategy to maximize the activating area in the dorsal column (DC) and, thus, paresthesia coverage in clinical practice.
MATERIALS AND METHODS: A new three-dimensional spinal cord model at the T10 vertebral level was developed to simulate neural activation induced by the electric field distribution produced by different typical four-contact electrode polarities in single- and dual-lead stimulation. Our approach consisted of the combination of a finite element model of the spinal cord developed in COMSOL Multiphysics and a nerve fiber model implemented in MATLAB. Five evaluation parameters were evaluated, namely, the recruitment ratio, the perception and discomfort thresholds, and the activating area and depth. The results were compared quantitatively.
RESULTS: The dual-guarded cathode presents the maximum activating area and depth in single- and dual-lead stimulation. However, the lowest value of the ratio between the perception threshold in DC and the perception threshold in the dorsal root (DR) is achieved when the guarded cathode is programmed. Although the two versions of bipolar polarity (namely bipolar 1 and bipolar 2) produce higher activating area and depth than the guarded cathode, they are suitable for producing DR stimulation. Similarly, dual-lead stimulation is likely to activate DR fibers because the electrodes are closer to these fibers.
CONCLUSIONS: The results suggest that the activating area in the DC is maximized by using the dual-guarded cathode both in single- and dual-lead stimulation modes. However, DC nerve fibers are preferentially stimulated when the guarded cathode is used. According to these results, the new electrode programming strategy that we propose for clinical practice first uses the dual-guarded cathode, but, if the DR nerve fibers are activated, it then uses guarded cathode polarity.
© 2018 International Neuromodulation Society.

Entities:  

Keywords:  Computational model; dorsal column stimulation; dorsal root stimulation; electrode polarity; spinal cord stimulation

Mesh:

Year:  2018        PMID: 30586207     DOI: 10.1111/ner.12909

Source DB:  PubMed          Journal:  Neuromodulation        ISSN: 1094-7159


  2 in total

Review 1.  Spinal cord stimulation programming: a crash course.

Authors:  Breanna Sheldon; Michael D Staudt; Lucian Williams; Tessa A Harland; Julie G Pilitsis
Journal:  Neurosurg Rev       Date:  2020-04-15       Impact factor: 3.042

2.  The Quasi-uniform assumption for Spinal Cord Stimulation translational research.

Authors:  Niranjan Khadka; Dennis Q Truong; Preston Williams; John H Martin; Marom Bikson
Journal:  J Neurosci Methods       Date:  2019-10-04       Impact factor: 2.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.