Anesthesia depth monitoring using alternative placement of entropy sensors: a prospective study.

David I Vachnadze1, Boris A Akselrod2, Denis A Guskov2, Alevtina V Goncharova2.   

Abstract

Spectral entropy is based on analysis of variations in electroencephalography and frontal electromyography, and is a safe and reliable method for anesthesia depth monitoring. However, standard frontal positioning of entropy electrodes in patients undergoing cardiac surgery is sometimes challenging. The present study aimed to compare standard entropy sensor placement with an alternative (infraorbital) site. This prospective study included 20 patients who underwent cardiovascular surgery at the authors' center. Monitoring was performed with standard and alternative entropy electrode positions from patient admission to surgery to transfer to the intensive care unit. Data were recorded every 15 s; all data were analyzed and compared using Bland-Altman, scatter plot with Pearson correlation coefficient, and sensitivity/specificity analyses. Overall, 20,784 pairs of response entropy (RE) and state entropy (SE) indexes were collected. Bland-Altman analysis revealed a mean difference in RE of 0.37 (95% LOA - 7.09, 7.88) and SE 0.69 (95% LOA - 5.95, 7.31); with 3.46% (720/20,784) RE and 3.40% (706/10,790) SE values lying outside of the limits of agreement. Correlation analysis revealed strong positive correlation in both cases: RE, r = 0.983, p < 0.05; SE, r = 0.984; p < 0.05. Sensitivity/specificity analysis revealed 98.1% sensitivity, 93.3% specificity and 97.1% test efficiency for RE, and 99.2%, 95.1% and 98.5% for SE, respectively. Infraorbital entropy sensor placement in patients undergoing cardiovascular surgery is reliable and effective. The strong positive correlation between the two methods of registration enables alternative entropy measurement when frontal placement is not possible.

Entities:  

Keywords:  Anesthesia depth; Entropy; Neuromonitoring; Spectral entropy

Mesh:

Year:  2018        PMID: 30569422     DOI: 10.1007/s10877-018-00238-z

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  15 in total

1.  A comparison of frontal and occipital bispectral index values obtained during neurosurgical procedures.

Authors:  Toshie Shiraishi; Hiroyuki Uchino; Takeshi Sagara; Nagao Ishii
Journal:  Anesth Analg       Date:  2004-06       Impact factor: 5.108

2.  Description of the Entropy algorithm as applied in the Datex-Ohmeda S/5 Entropy Module.

Authors:  H Viertiö-Oja; V Maja; M Särkelä; P Talja; N Tenkanen; H Tolvanen-Laakso; M Paloheimo; A Vakkuri; A Yli-Hankala; P Meriläinen
Journal:  Acta Anaesthesiol Scand       Date:  2004-02       Impact factor: 2.105

3.  BIS-vista occipital montage in patients undergoing neurosurgical procedures during propofol-remifentanil anesthesia.

Authors:  Ashraf A Dahaba; Ji Xiu Xue; Guo Guang Zhao; Qing Hai Liu; Guo Xun Xu; Helmar Bornemann; Peter H Rehak; Helfried Metzler
Journal:  Anesthesiology       Date:  2010-03       Impact factor: 7.892

4.  Spectral entropy monitoring reduces anesthetic dosage for patients undergoing off-pump coronary artery bypass graft surgery.

Authors:  Ma Jiahai; Wang Xueyan; Xie Yonggang; Yu Jianhong; He Qunhui; Li Zhi; Du Juan; Jiang Xiuliang
Journal:  J Cardiothorac Vasc Anesth       Date:  2012-04-12       Impact factor: 2.628

5.  An alternative position for the BIS-Vista montage in frontal approach neurosurgical cases.

Authors:  Priscilla Nelson; Jonas A Nelson; Alexander J Chen; W Andrew Kofke
Journal:  J Neurosurg Anesthesiol       Date:  2013-04       Impact factor: 3.956

Review 6.  Awareness in cardiac anesthesia.

Authors:  Leon Serfontein
Journal:  Curr Opin Anaesthesiol       Date:  2010-02       Impact factor: 2.706

Review 7.  Clinical effectiveness and cost-effectiveness of depth of anaesthesia monitoring (E-Entropy, Bispectral Index and Narcotrend): a systematic review and economic evaluation.

Authors:  J Shepherd; J Jones; Gk Frampton; J Bryant; L Baxter; K Cooper
Journal:  Health Technol Assess       Date:  2013-08       Impact factor: 4.014

8.  Alternative placement of bispectral index electrode for monitoring depth of anesthesia during neurosurgery.

Authors:  Phuping Akavipat; Nate Hungsawanich; Rungruedee Jansin
Journal:  Acta Med Okayama       Date:  2014       Impact factor: 0.892

9.  Comparison of bispectral index scores from the standard frontal sensor position with those from an alternative mandibular position.

Authors:  Shin Young Lee; Young Sung Kim; Byung Gun Lim; Heezoo Kim; Myoung-Hoon Kong; Il-Ok Lee
Journal:  Korean J Anesthesiol       Date:  2014-04-28

Review 10.  Spectral entropy monitoring for adults and children undergoing general anaesthesia.

Authors:  Anjolie Chhabra; Rajeshwari Subramaniam; Anurag Srivastava; Hemanshu Prabhakar; Mani Kalaivani; Saloni Paranjape
Journal:  Cochrane Database Syst Rev       Date:  2016-03-14
View more
  1 in total

Review 1.  End of year summary 2019: anaesthesia and airway management.

Authors:  Jan F A Hendrickx; Tom Van Zundert; Andre M De Wolf
Journal:  J Clin Monit Comput       Date:  2020-01-02       Impact factor: 2.502

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.