Literature DB >> 3055908

Hemodynamic response to treadmill exercise in normal volunteers: an assessment by Doppler ultrasonic measurement of ascending aortic blood velocity and acceleration.

N Mehta1, G Boyle, D Bennett, S Gilmour, M I Noble, C M Mills, S Pugh.   

Abstract

Accurate assessment of ascending aortic blood velocity indices and reproducibility of a Doppler ultrasonic system during exercise were determined; the Doppler technique was then used to assess the effects of age, sex, and beta blockade on exercise hemodynamics. Doppler-determined velocity correlated well with an invasive electromagnetic system. Reproducibility of Doppler variables during three exercise tests was high (coefficient of variation less than 10%) and did not deteriorate appreciably with exercise. Peak velocity (PV) and maximum acceleration (MA) were inversely related to age, the relationship being more significant during exercise, whereas the systolic velocity integral showed no such relationship either at rest or during exercise. Doppler variables showed no difference between sexes, except at high levels of exercise. Beta blockade markedly attenuated the exercise response as shown by significant decreases in both MA and PV during exercise. The Doppler velocity data presented in this study provide a reference against which previously documented changes in exercising ischemic patients can be better related.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3055908     DOI: 10.1016/0002-8703(88)90455-3

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  4 in total

1.  Reproducibility of Doppler blood flow velocity waveform measurements: study on variability within and between day and during haemodynamic intervention in normal subjects.

Authors:  G H Rimoy; N K Bhaskar; P C Rubin
Journal:  Eur J Clin Pharmacol       Date:  1991       Impact factor: 2.953

2.  Effects of rider position on continuous wave Doppler responses to maximal cycle ergometry.

Authors:  W D Franke; C B Betz; R H Humphrey
Journal:  Br J Sports Med       Date:  1994-03       Impact factor: 13.800

3.  Validation of the beat to beat measurement of blood velocity in the human ascending aorta by a new high temporal resolution Doppler ultrasound spectral analyser.

Authors:  A J Coats; C Murphy; J Conway; P Sleight
Journal:  Br Heart J       Date:  1992-08

4.  A placebo controlled comparison of the effects of metoprolol and celiprolol on echo-Doppler measurements of cardiovascular function in normal volunteers.

Authors:  B Silke; A Thompson; A Leitch; J G Riddell
Journal:  Br J Clin Pharmacol       Date:  1995-07       Impact factor: 4.335