Volume-of-interest CT imaging with dynamic beam filtering using multiple aperture devices.

Wenying Wang1, Grace J Gang1, Andrew Mao1, Alejandro Sisniega1, Jeffrey H Siewerdsen1, J Webster Stayman1.   

Abstract

Interior tomography is promising approach for retaining high quality CT images within a volume-of-interest (VOI) while reducing the total patient dose. A static collimating filter can only image a centered symmetric VOI, which requires careful patient positioning and may be suboptimal for many clinical applications. Multiple aperture devices (MADs) are an emerging technology based on sequential binary filters that can provide a wide range of fluence patterns that may be adjusted dynamically with relatively small motions. In this work, we introduce a general approach for VOI imaging using MAD-based fluence field modulation (FFM). Physical experiments using a CT test bench are conducted illustrating off-center x-ray beam control for imaging the spine in an abdominal phantom. Image quality and dose metrics are computed for both standard full-field CT and VOI CT. We find that the image quality within the VOI can be preserved for VOI CT with a significant drop in integral dose as compared with a standard full-field protocol.

Entities:  

Year:  2018        PMID: 30556060      PMCID: PMC6291005     

Source DB:  PubMed          Journal:  Conf Proc Int Conf Image Form Xray Comput Tomogr


  4 in total

1.  Dynamic fluence field modulation in computed tomography using multiple aperture devices.

Authors:  Grace J Gang; Andrew Mao; Wenying Wang; Jeffrey H Siewerdsen; Aswin Mathews; Satomi Kawamoto; Reuven Levinson; J Webster Stayman
Journal:  Phys Med Biol       Date:  2019-05-21       Impact factor: 3.609

2.  Volume-of-interest Imaging Using Multiple Aperture Devices.

Authors:  W Wang; G J Gang; J H Siewerdsen; J W Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-03-01

3.  Predicting image properties in penalized-likelihood reconstructions of flat-panel CBCT.

Authors:  Wenying Wang; Grace J Gang; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Med Phys       Date:  2018-11-20       Impact factor: 4.071

4.  Heart-centered positioning and tailored beam-shaping filtration for reduced radiation dose in coronary artery calcium imaging: A Multi-Ethnic Study of Atherosclerosis (MESA) Study.

Authors:  Brendan Colvert; Marzia Rigolli; Amanda Craine; Michael Criqui; Francisco Contijoch
Journal:  Med Phys       Date:  2021-08-03       Impact factor: 4.506

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.