Literature DB >> 30553102

Bubble-free rapid microfluidic PCR.

Sang Hun Lee1, Jihwan Song1, Byungrae Cho2, SoonGweon Hong1, Ori Hoxha1, Taewook Kang3, Dongchoul Kim4, Luke P Lee5.   

Abstract

Microfluidic polymerase chain reaction (PCR) has been of great interest owing to its ability to perform rapid and specific nucleic acid amplification and analysis on small volumes of samples. One of the major drawbacks of microfluidic PCR is bubble generation and reagent evaporation, which can cause malfunctions. Here, through theoretical modeling and characterization of bubble behavior, we propose a bubble-free microfluidic PCR device via controlled fluid transfer. Our approach exploits a thin impermeable polyethylene (PE) top layer that minimizes the generation of bubbles by inhibiting mass transport along a vertical direction. Simulation results demonstrate that a calculated mass flow difference of approximately 370% can be obtained by utilizing an impermeable membrane as the vertical barrier layer. To demonstrate proof-of-concept, two nanoporous polymeric materials, poly(dimethylsiloxane) (PDMS) and PE, were used for stand-alone self-powered sample loading (approximately 70 s) and for use as a vertical barrier layer, respectively. Consequently, we demonstrate successful amplification of the cMET gene, a nucleic acid (NA) biomarker for lung cancer, and complete an ultrafast PCR test in less than 3 min using a high powered Peltier-based thermal cycler under bubble-free conditions. This approach will result in a new paradigm for ultrafast molecular diagnosis and can facilitate NA-based nearly instantaneous diagnostics for point-of-care testing and for personalized and preventive medicine.
Copyright © 2018. Published by Elsevier B.V.

Entities:  

Keywords:  Bubble-free microfluidic PCR; Lung cancer biomarker; Molecular diagnosis; Nanoporous polymers; Polymerase chain reaction

Mesh:

Substances:

Year:  2018        PMID: 30553102     DOI: 10.1016/j.bios.2018.10.005

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  14 in total

1.  Carbon Nanomaterials for Biomedical Application.

Authors:  Sang Hun Lee; Won-Yeop Rho; Hyejin Chang; Jong Hun Lee; Jaehi Kim; Seung Hwan Lee; Bong-Hyun Jun
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

2.  A microfluidic alternating-pull-push active digitization method for sample-loss-free digital PCR.

Authors:  Xin Zhou; Gopi Chandran Ravichandran; Peng Zhang; Yang Yang; Yong Zeng
Journal:  Lab Chip       Date:  2019-11-13       Impact factor: 6.799

Review 3.  Emergence of debubblers in microfluidics: A critical review.

Authors:  Mingpeng Yang; Nan Sun; Yong Luo; Xiaochen Lai; Peiru Li; Zhenyu Zhang
Journal:  Biomicrofluidics       Date:  2022-06-21       Impact factor: 3.258

4.  One-Step Nucleic Acid Purification and Noise-Resistant Polymerase Chain Reaction by Electrokinetic Concentration for Ultralow-Abundance Nucleic Acid Detection.

Authors:  Wei Ouyang; Jongyoon Han
Journal:  Angew Chem Int Ed Engl       Date:  2020-04-30       Impact factor: 15.336

5.  Lateral Degassing Method for Disposable Film-Chip Microfluidic Devices.

Authors:  Suhee Park; Hyungseok Cho; Junhyeong Kim; Ki-Ho Han
Journal:  Membranes (Basel)       Date:  2021-04-26

Review 6.  Bridging the gap between development of point-of-care nucleic acid testing and patient care for sexually transmitted infections.

Authors:  Kuangwen Hsieh; Johan H Melendez; Charlotte A Gaydos; Tza-Huei Wang
Journal:  Lab Chip       Date:  2022-02-01       Impact factor: 7.517

7.  Point-of-Care PCR Assays for COVID-19 Detection.

Authors:  Niharika Gupta; Shine Augustine; Tarun Narayan; Alan O'Riordan; Asmita Das; D Kumar; John H T Luong; Bansi D Malhotra
Journal:  Biosensors (Basel)       Date:  2021-05-01

Review 8.  Rapid PCR Powered by Microfluidics: A Quick Review Under the Background of COVID-19 Pandemic.

Authors:  Xiaobin Dong; Luyao Liu; Yunping Tu; Jing Zhang; Guijun Miao; Lulu Zhang; Shengxiang Ge; Ningshao Xia; Duli Yu; Xianbo Qiu
Journal:  Trends Analyt Chem       Date:  2021-06-24       Impact factor: 12.296

9.  Ultrasensitive Stress Biomarker Detection Using Polypyrrole Nanotube Coupled to a Field-Effect Transistor.

Authors:  Kyung Ho Kim; Sang Hun Lee; Sung Eun Seo; Joonwon Bae; Seon Joo Park; Oh Seok Kwon
Journal:  Micromachines (Basel)       Date:  2020-04-22       Impact factor: 2.891

Review 10.  Point-of-Care Strategies for Detection of Waterborne Pathogens.

Authors:  Sandeep Kumar; Monika Nehra; Jyotsana Mehta; Neeraj Dilbaghi; Giovanna Marrazza; Ajeet Kaushik
Journal:  Sensors (Basel)       Date:  2019-10-16       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.