Mario Hevesi1,2, Jeffrey A Macalena1, Isabella T Wu2, Christopher L Camp2, Bruce A Levy2, Elizabeth A Arendt1, Michael J Stuart2, Aaron J Krych3. 1. Department of Orthopaedic Surgery, University of Minnesota, 2450 Riverside Ave, Suite R200, Minneapolis, MN, 55454, USA. 2. Department of Orthopedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA. 3. Department of Orthopedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA. krych.aaron@mayo.edu.
Abstract
PURPOSE: Various implant materials have been used in medial, opening-wedge high tibial osteotomy (HTO) including traditional metal and modern polyetheretherketone (PEEK) implants. The purpose of this study was to compare metal and PEEK implants and determine safety, varus deformity correction, as well as short- to mid-term hardware removal and arthroplasty rates. METHODS: HTO performed with metal and PEEK implants were reviewed between 2000 and 2015 at two institutions with a minimum of 2 years follow-up. Postoperative complications, radiographic measures, and osteotomy union were compared between groups using Kruskal-Wallis and Fisher's exact testing. Survival free of hardware removal and arthroplasty was compared between groups using Kaplan-Meier testing. Risk factors for HTO conversion to arthroplasty were examined using Cox proportional hazards regression. RESULTS: Ninety-five HTOs were performed in 90 patients (59 M, 31 F) using 50 metal and 45 PEEK implants. Mean follow-up was 4.2 years (range 2.0-16.5). Two metal and two PEEK HTO patients experienced nonunions, resulting in revision HTO at a mean of 1.0 years postoperatively (range 0.4-1.4 years). Both implant groups demonstrated similar, significant improvements in coronal deformity, with mean angulation improving from 6.0° and 5.4° varus preoperatively to 1.1° and 1.0° valgus postoperatively for the metal (p < 0.01) and PEEK groups (p < 0.01), respectively. 2- and 5-year hardware removal-free survival was 94% and 94% for PEEK, which was significantly superior to 80% and 73% observed for metal (p = 0.02). 2- and 5-year arthroplasty-free survival was similar for the metal (98% and 94%) and PEEK groups (100% and 78%) (n.s.). HTO performed for focal cartilage defects was observed to demonstrate decreased arthroplasty risk (HR 0.36, p = 0.03) when compared to HTO performed for osteoarthritis. CONCLUSIONS: Both metal and PEEK implants were found to be effective in obtaining and maintaining coronal varus deformity correction, with 88% overall arthroplasty-free survival at 5 years. Metal fixation demonstrated a higher rate of hardware removal while HTO performed for medial compartment osteoarthritis predicted conversation to arthroplasty. LEVEL OF EVIDENCE: III.
PURPOSE: Various implant materials have been used in medial, opening-wedge high tibial osteotomy (HTO) including traditional metal and modern polyetheretherketone (PEEK) implants. The purpose of this study was to compare metal and PEEK implants and determine safety, varus deformity correction, as well as short- to mid-term hardware removal and arthroplasty rates. METHODS: HTO performed with metal and PEEK implants were reviewed between 2000 and 2015 at two institutions with a minimum of 2 years follow-up. Postoperative complications, radiographic measures, and osteotomy union were compared between groups using Kruskal-Wallis and Fisher's exact testing. Survival free of hardware removal and arthroplasty was compared between groups using Kaplan-Meier testing. Risk factors for HTO conversion to arthroplasty were examined using Cox proportional hazards regression. RESULTS: Ninety-five HTOs were performed in 90 patients (59 M, 31 F) using 50 metal and 45 PEEK implants. Mean follow-up was 4.2 years (range 2.0-16.5). Two metal and two PEEK HTO patients experienced nonunions, resulting in revision HTO at a mean of 1.0 years postoperatively (range 0.4-1.4 years). Both implant groups demonstrated similar, significant improvements in coronal deformity, with mean angulation improving from 6.0° and 5.4° varus preoperatively to 1.1° and 1.0° valgus postoperatively for the metal (p < 0.01) and PEEK groups (p < 0.01), respectively. 2- and 5-year hardware removal-free survival was 94% and 94% for PEEK, which was significantly superior to 80% and 73% observed for metal (p = 0.02). 2- and 5-year arthroplasty-free survival was similar for the metal (98% and 94%) and PEEK groups (100% and 78%) (n.s.). HTO performed for focal cartilage defects was observed to demonstrate decreased arthroplasty risk (HR 0.36, p = 0.03) when compared to HTO performed for osteoarthritis. CONCLUSIONS: Both metal and PEEK implants were found to be effective in obtaining and maintaining coronal varus deformity correction, with 88% overall arthroplasty-free survival at 5 years. Metal fixation demonstrated a higher rate of hardware removal while HTO performed for medial compartment osteoarthritis predicted conversation to arthroplasty. LEVEL OF EVIDENCE: III.
Entities:
Keywords:
Cartilage; High tibial osteotomy; Knee; Preservation; Varus
Authors: Joon Ho Wang; Ji Hoon Bae; Hong Chul Lim; Won Yong Shon; Cheol Woong Kim; Jae Woo Cho Journal: Am J Sports Med Date: 2009-08-14 Impact factor: 6.202
Authors: R W Brouwer; T M Raaij van; S M A Bierma-Zeinstra; A P Verhagen; T S C Jakma; J A N Verhaar Journal: Cochrane Database Syst Rev Date: 2007-07-18
Authors: Robert D A Gaasbeek; Loes Nicolaas; Willard J Rijnberg; Corne J M van Loon; Albert van Kampen Journal: Int Orthop Date: 2009-08-27 Impact factor: 3.075
Authors: Mario Hevesi; Jeffrey A Macalena; Isabella T Wu; Christopher L Camp; Bruce A Levy; Elizabeth A Arendt; Michael J Stuart; Aaron J Krych Journal: Knee Surg Sports Traumatol Arthrosc Date: 2019-06-26 Impact factor: 4.342