Literature DB >> 30552468

High tibial osteotomy with modern PEEK implants is safe and leads to lower hardware removal rates when compared to conventional metal fixation: a multi-center comparison study.

Mario Hevesi1,2, Jeffrey A Macalena1, Isabella T Wu2, Christopher L Camp2, Bruce A Levy2, Elizabeth A Arendt1, Michael J Stuart2, Aaron J Krych3.   

Abstract

PURPOSE: Various implant materials have been used in medial, opening-wedge high tibial osteotomy (HTO) including traditional metal and modern polyetheretherketone (PEEK) implants. The purpose of this study was to compare metal and PEEK implants and determine safety, varus deformity correction, as well as short- to mid-term hardware removal and arthroplasty rates.
METHODS: HTO performed with metal and PEEK implants were reviewed between 2000 and 2015 at two institutions with a minimum of 2 years follow-up. Postoperative complications, radiographic measures, and osteotomy union were compared between groups using Kruskal-Wallis and Fisher's exact testing. Survival free of hardware removal and arthroplasty was compared between groups using Kaplan-Meier testing. Risk factors for HTO conversion to arthroplasty were examined using Cox proportional hazards regression.
RESULTS: Ninety-five HTOs were performed in 90 patients (59 M, 31 F) using 50 metal and 45 PEEK implants. Mean follow-up was 4.2 years (range 2.0-16.5). Two metal and two PEEK HTO patients experienced nonunions, resulting in revision HTO at a mean of 1.0 years postoperatively (range 0.4-1.4 years). Both implant groups demonstrated similar, significant improvements in coronal deformity, with mean angulation improving from 6.0° and 5.4° varus preoperatively to 1.1° and 1.0° valgus postoperatively for the metal (p < 0.01) and PEEK groups (p < 0.01), respectively. 2- and 5-year hardware removal-free survival was 94% and 94% for PEEK, which was significantly superior to 80% and 73% observed for metal (p = 0.02). 2- and 5-year arthroplasty-free survival was similar for the metal (98% and 94%) and PEEK groups (100% and 78%) (n.s.). HTO performed for focal cartilage defects was observed to demonstrate decreased arthroplasty risk (HR 0.36, p = 0.03) when compared to HTO performed for osteoarthritis.
CONCLUSIONS: Both metal and PEEK implants were found to be effective in obtaining and maintaining coronal varus deformity correction, with 88% overall arthroplasty-free survival at 5 years. Metal fixation demonstrated a higher rate of hardware removal while HTO performed for medial compartment osteoarthritis predicted conversation to arthroplasty. LEVEL OF EVIDENCE: III.

Entities:  

Keywords:  Cartilage; High tibial osteotomy; Knee; Preservation; Varus

Mesh:

Substances:

Year:  2018        PMID: 30552468     DOI: 10.1007/s00167-018-5329-0

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  26 in total

1.  [Value of corrective osteotomies in the treatment of certain knee diseases with axial deviation].

Authors:  J DEBEYRE; D PATTE
Journal:  Rev Rhum Mal Osteoartic       Date:  1962-12

2.  Opening wedge high tibial osteotomy using a novel technique: early results and complications.

Authors:  A Amendola; P J Fowler; R Litchfield; S Kirkley; M Clatworthy
Journal:  J Knee Surg       Date:  2004-07       Impact factor: 2.757

Review 3.  Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length.

Authors:  T W Dugdale; F R Noyes; D Styer
Journal:  Clin Orthop Relat Res       Date:  1992-01       Impact factor: 4.176

4.  Osteotomy for medial compartment arthritis of the knee using a closing wedge or an opening wedge controlled by a Puddu plate. A one-year randomised, controlled study.

Authors:  R W Brouwer; S M A Bierma-Zeinstra; T M van Raaij; J A N Verhaar
Journal:  J Bone Joint Surg Br       Date:  2006-11

5.  G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences.

Authors:  Franz Faul; Edgar Erdfelder; Albert-Georg Lang; Axel Buchner
Journal:  Behav Res Methods       Date:  2007-05

6.  Medial open wedge high tibial osteotomy: the effect of the cortical hinge on posterior tibial slope.

Authors:  Joon Ho Wang; Ji Hoon Bae; Hong Chul Lim; Won Yong Shon; Cheol Woong Kim; Jae Woo Cho
Journal:  Am J Sports Med       Date:  2009-08-14       Impact factor: 6.202

7.  High tibial osteotomy with Puddu plate for the treatment of varus gonarthrosis.

Authors:  Mehmet Asik; Cengiz Sen; Bulent Kilic; S Bora Goksan; Feyyaz Ciftci; Omer F Taser
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-04-11       Impact factor: 4.342

8.  Evaluation of patellar height and measurement methods after valgus high tibial osteotomy.

Authors:  Hayrettin Kesmezacar; Rifat Erginer; Tahir Ogut; Aksel Seyahi; Muharrem Babacan; Yuksel Tenekecioglu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-01-08       Impact factor: 4.342

Review 9.  Osteotomy for treating knee osteoarthritis.

Authors:  R W Brouwer; T M Raaij van; S M A Bierma-Zeinstra; A P Verhagen; T S C Jakma; J A N Verhaar
Journal:  Cochrane Database Syst Rev       Date:  2007-07-18

10.  Correction accuracy and collateral laxity in open versus closed wedge high tibial osteotomy. A one-year randomised controlled study.

Authors:  Robert D A Gaasbeek; Loes Nicolaas; Willard J Rijnberg; Corne J M van Loon; Albert van Kampen
Journal:  Int Orthop       Date:  2009-08-27       Impact factor: 3.075

View more
  4 in total

1.  Authors' response to critical comments: High tibial osteotomy with modern PEEK implants is safe and leads to lower hardware removal rates when compared to conventional metal fixation: a multi-center comparison study.

Authors:  Mario Hevesi; Jeffrey A Macalena; Isabella T Wu; Christopher L Camp; Bruce A Levy; Elizabeth A Arendt; Michael J Stuart; Aaron J Krych
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-26       Impact factor: 4.342

2.  High Tibial Osteotomy for Varus Deformity of the Knee.

Authors:  Ryan Murray; Philipp W Winkler; Humza S Shaikh; Volker Musahl
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2021-07-09

3.  Day-Case Opening Wedge High Tibial Osteotomy With Intraosseous PEEK Implant.

Authors:  Martin Polacek; Cecilie P Nyegaard; Fredrik Høien
Journal:  Arthrosc Sports Med Rehabil       Date:  2020-04-08

4.  Facile surface functional polyetheretherketone with antibacterial and immunoregulatory activities for enhanced regeneration toward bacterium-infected bone destruction.

Authors:  An'an Sun; Xi Lin; Zhiqiang Xue; Jiyue Huang; Xinxin Bai; Lingling Huang; Xinhua Lin; Shaohuang Weng; Min Chen
Journal:  Drug Deliv       Date:  2021-12       Impact factor: 6.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.