Literature DB >> 17075089

Osteotomy for medial compartment arthritis of the knee using a closing wedge or an opening wedge controlled by a Puddu plate. A one-year randomised, controlled study.

R W Brouwer1, S M A Bierma-Zeinstra, T M van Raaij, J A N Verhaar.   

Abstract

A prospective, randomised, controlled trial compared two different techniques of high tibial osteotomy with a lateral closing wedge or a medial opening wedge, stabilised by a Puddu plate. The clinical outcome and radiological results were examined at one year. The primary outcome measure was the achievement of an overcorrection of valgus of 4 degrees . Secondary outcome measures were the severity of pain (visual analogue scale), knee function (Hospital for Special Surgery score), and walking distance. Between January 2001 and April 2004, 92 patients were randomised to one or other of the techniques. At follow-up at one year the post-operative hip-knee-ankle angle was 3.4 degrees (+/- 3.6 degrees SD) valgus after a closing wedge and 1.3 degrees (+/- 4.7 degrees SD) of valgus after an opening wedge. The adjusted mean difference of 2.1 degrees was significant (p = 0.02). The deviation from 4 degrees of valgus alignment was 2.7 degrees (+/- 2.4 degrees SD) in the closing wedge and 4.0 degrees (+/- 3.6 degrees sd) in the opening-wedge groups. The adjusted mean difference of 1.67 degrees was also significant (p = 0.01). The severity of pain, knee score and walking ability improved in both groups, but the difference was not significant. Because of pain, the staples required removal in 11 (23%) patients in the closing-wedge group and a Puddu plate was removed in 27 (60%) patients in the opening-wedge group. This difference was significant (p < 0.001). We conclude that closing-wedge osteotomy achieves a more accurate correction with less morbidity, although both techniques had improved the function of the knee at one year after the procedure.

Entities:  

Mesh:

Year:  2006        PMID: 17075089     DOI: 10.1302/0301-620X.88B11.17743

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  66 in total

1.  Change in limb length after high tibial osteotomy using computer-assisted surgery: a comparative study of closed- and open-wedge osteotomies.

Authors:  Dae Kyung Bae; Sang Jun Song; Hwan Jin Kim; Jae Wan Seo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-20       Impact factor: 4.342

Review 2.  Surgical treatment for early osteoarthritis. Part II: allografts and concurrent procedures.

Authors:  A H Gomoll; G Filardo; F K Almqvist; W D Bugbee; M Jelic; J C Monllau; G Puddu; W G Rodkey; P Verdonk; R Verdonk; S Zaffagnini; M Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-09       Impact factor: 4.342

Review 3.  Infections after high tibial osteotomy.

Authors:  Konstantinos Anagnostakos; Philipp Mosser; Dieter Kohn
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-23       Impact factor: 4.342

4.  Applicability of a modified angular correction measurement method for open-wedge high tibial osteotomy.

Authors:  James Moore; Lydia Mychaltchouk; Frédéric Lavoie
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-02       Impact factor: 4.342

5.  Short-term safety and efficacy of a novel high tibial osteotomy system: a case controlled study.

Authors:  Alan Getgood; Brett Collins; Konrad Slynarski; Emilia Kurowska; David Parker; Lars Engebretsen; Peter B MacDonald; Robert Litchfield
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-18       Impact factor: 4.342

6.  Medial opening wedge high-tibial osteotomy using a kinematic navigation system versus a conventional method: a 1-year retrospective, comparative study.

Authors:  Sung-Jae Kim; Yong-Gon Koh; Yong-Min Chun; Yong-Chan Kim; Young-Sik Park; Chang-Hun Sung
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-10-11       Impact factor: 4.342

7.  Accuracy of high tibial osteotomy: comparison between open- and closed-wedge technique.

Authors:  S Hankemeier; P Mommsen; C Krettek; M Jagodzinski; J Brand; C Meyer; R Meller
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-12-24       Impact factor: 4.342

8.  Simultaneous bilateral opening-wedge high tibial osteotomy with early full weight-bearing exercise.

Authors:  Ryohei Takeuchi; Masato Aratake; Haruhiko Bito; Izumi Saito; Ken Kumagai; Hiroyuki Ishikawa; Yasushi Akamatsu; Yohei Sasaki; Tomoyuki Saito
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-09-02       Impact factor: 4.342

9.  Medial open wedge vs. lateral closed wedge high tibial osteotomy - Indications based on the findings of patellar height, leg length, torsional correction and clinical outcome in one hundred cases.

Authors:  Felix Ferner; Christoph Lutter; Joerg Dickschas; Wolf Strecker
Journal:  Int Orthop       Date:  2018-10-24       Impact factor: 3.075

Review 10.  Closing wedge osteotomy of the tibia and the femur in the treatment of gonarthrosis.

Authors:  Courtney Sherman; Miguel E Cabanela
Journal:  Int Orthop       Date:  2009-10-15       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.