Kyuyeon Cho1, Dong Hui Lim1, Chan Min Yang1, Eui Sang Chung2, Tae Young Chung3.
Abstract
PURPOSE: To evaluate and compare published methods of calculating intraocular lens (IOL) power following myopic laser refractive surgery.Entities:
Keywords: Barrett True-K; Intraocular lenses; Pentacam; Refractive surgical procedures; Scheimpflug
Mesh:
Year: 2018 PMID: 30549474 PMCID: PMC6288016 DOI: 10.3341/kjo.2018.0008
Source DB: PubMed Journal: Korean J Ophthalmol ISSN: 1011-8942
Preoperative patient demographics of the initial 69 patients (69 eyes) enrolled before cataract surgery
Values are presented as mean ± standard deviation (range) or number.
OD = right eye; OS = left eye; UCVA = uncorrected visual acuity; logMAR = logarithm of the minimum angle of resolution; BCVA = best-corrected visual acuity; D = diopter; PCI = partial coherence interferometry; ACD = anterior chamber depth; K = keratometry.
Fig. 1Mean numeric prediction error (PE). A comparison of mean arithmetic PE between the Haigis-L, Shammas, Barrett True-K, and Wang-Koch-Maloney (WKM) methods with Haigis formulas using input values from the Pentacam system. The most accurate corneal power adjustment and formula combinations were the Haigis-L, Barrett True-K, and total corneal refractive power (TCRP) 4 mm (Haigis). TNP = true net power; TRP = total refractive power.
Fig. 2Mean absolute prediction error. A comparison of mean absolute prediction error values calculated with the Haigis-L, Shammas, Barrett True-K, and Wang-Koch-Maloney (WKM) with the Haigis formulae using values obtained with the Pentacam system. The most accurate corneal power adjustment and formula combinations were the Haigis-L, Barrett True-K, and total corneal refractive power (TCRP) 4 mm (Haigis). TNP = true net power; TRP = total refractive power.
Fig. 3Percentages of eyes within ±0.5 and ±1.0 diopters (D) of the target refraction. A comparison of the percentages of eyes within ±0.5 and ±1.0 D of the target refraction for the difference formulae (the Haigis-L, Shammas, Barrett True-K, and Wang-Koch-Maloney [WKM] with Haigis formulae) using values obtained from the Pentacam system. The most accurate corneal power adjustment and formula combinations were the Haigis-L, Barrett True-K, and total corneal refractive power (TCRP) 4 mm (Haigis) and total refractive power (TRP) 4 mm (Haigis). TNP = true net power.