| Literature DB >> 30546593 |
Sho Hashimoto1, Jun Shiraishi1, Masayoshi Kimura1, Marie Nishikawa1, Takashi Yanagiuchi1, Daisuke Ito1, Eigo Kishita1, Hirokazu Yokoi1, Masayuki Hyogo1, Takatomo Shima1, Takahisa Sawada1, Yoshio Kohno1.
Abstract
Arteriovenous fistula (AVF) after trans-radial catheterization is an extremely rare complication. A 61-year-old man experienced a painful swelling in the left radial punctured site. The findings of vascular ultrasound and angiography led to a diagnosis of an iatrogenic radial AVF. We performed continuous compression using a hemostatic band for 24 h after which the radial AVF completely disappeared without vessel occlusion, and no relapse occurred. Eight cases of catheterization-induced radial AVF have been mentioned in the literature, but the treatment has not been noninvasive in any case. This is the first report of an iatrogenic radial AVF that was noninvasively repaired using continuous low-pressure compression with a hemostatic band. <Learning objective: Arteriovenous fistula (AVF) after trans-radial catheterization is a rare complication. The literature reports only 8 cases of catheterization-induced radial AVF and no patient has been cured noninvasively. This is the first report of an iatrogenic radial AVF that was repaired noninvasively. We believe that continuous low-pressure compression using a hemostatic band is an effective therapeutic option for this complication.>.Entities:
Keywords: Arteriovenous fistula; Hemostatic band; Non-invasive treatment; Radial artery; Vascular complication
Year: 2015 PMID: 30546593 PMCID: PMC6281843 DOI: 10.1016/j.jccase.2015.08.007
Source DB: PubMed Journal: J Cardiol Cases ISSN: 1878-5409