| Literature DB >> 30542283 |
Yan He1, Xiao Yan Wang1, Qiao Hu1, Xue Xue Chen1, Bing Ling1, Hai Ming Wei2.
Abstract
Objectives: To assess the value of contrast-enhanced ultrasound (CEUS) and acoustic radiation force impulse (ARFI) imaging for the differential diagnosis of benign and malignant thyroid nodules.Entities:
Keywords: acoustic radiation force impulse-imaging; contrast-enhanced ultrasound; receiver operating characteristic curve; shear wave velocity; thyroid nodule
Year: 2018 PMID: 30542283 PMCID: PMC6277905 DOI: 10.3389/fphar.2018.01363
Source DB: PubMed Journal: Front Pharmacol ISSN: 1663-9812 Impact factor: 5.810
Contrast-enhanced ultrasound modes of thyroid nodules.
| Pathology | Entry pattern | Regression pattern | Contrast pattern | |||||
|---|---|---|---|---|---|---|---|---|
| Wash-in earlier | Wash-in at the same time | Wash-in later | Wash-out earlier | Wash-out at the same time | Wash-out later | Concentric | Non-concentric | |
| Benign | 23 | 29 | 7 | 9 | 40 | 10 | 6 | 53 |
| Nodular goiter | 12 | 16 | 7 | 7 | 25 | 3 | 6 | 29 |
| Nodular goiter with nodular hyperplasia | 4 | 11 | – | 2 | 11 | 2 | – | 15 |
| Adenoma | 7 | 2 | – | – | 4 | 5 | – | 9 |
| Malignant | 9 | 7 | 13 | 17 | 11 | 1 | 22 | 7 |
| Papillary carcinoma | 8 | 7 | 12 | 16 | 11 | – | 21 | 6 |
| Follicular carcinoma | 1 | – | – | – | – | 1 | – | 1 |
| Metastasis carcinoma | – | – | 1 | 1 | – | – | 1 | – |
| χ2-value | 12.607 | 17.101 | 38.677 | |||||
| 0.002 | <0.001 | <0.001 | ||||||
ARFI results for thyroid nodules.
| Internal SWV value (m/s) | Surrounding SWV value (m/s) | SWV ratio | |
|---|---|---|---|
| 5.81 ± 3.21 (range: 0.97∼9.00) | 2.11 ± 0.45 (range: 1.24∼3.44) | 2.74 ± 1.40 (range: 0.56∼5.57) | |
| Papillary carcinoma | 5.86 ± 3.15 (range: 1.24∼9.00) | 2.10 ± 0.42 (range: 1.31∼3.44) | 2.79 ± 1.41 (range: 0.56∼5.57) |
| Follicular carcinoma | 1.65 ± 0.41 (range: 0.97∼2.00) | 1.48 ± 0.21 (range: 1.24∼1.70) | 1.12 |
| Metastasis carcinoma | 9.00 | 2.91 ± 0.23 (range: 2.55∼3.00) | 3.09 |
| 2.00 ± 1.17 (range: 0.51∼9.00) | 2.02 ± 0.40 (range: 1.16∼3.82) | 1.02 ± 0.62 (range: 0.20∼4.78) | |
| Nodular goiter | 2.02 ± 1.38 (range: 0.51∼9.00) | 2.01 ± 0.41 (range: 1.16∼3.32) | 1.03 ± 0.73 (range: 0.20∼4.78) |
| Nodular goiter with nodular hyperplasia | 2.13 ± 0.92 (range: 1.56∼8.40) | 1.99 ± 0.31 (range: 1.50∼3.82) | 1.08 ± 0.44 (range: 0.46∼2.41) |
| Adenoma | 1.74 ± 0.51 (range: 1.05∼3.80) | 2.12 ± 0.47 (range: 1.31∼3.23) | 0.87 ± 0.35 (range: 0.40∼1.48) |
Area under the ROC curve for the SWV value and the SWV ratio of thyroid nodules.
| Under curve area | 95% confidential interval | |||
|---|---|---|---|---|
| Lower limit | Upper limit | |||
| SWV value | 0.878 | <0.001 | 0.791 | 0.964 |
| SWV ratio | 0.875 | <0.001 | 0.785 | 0.964 |
FIGURE 1ROC curves of the SWV value and SWV ratio of thyroid nodules.
Comparison of various CEUS and ARFI indices for the diagnosis of thyroid nodules.
| Pathology | Sensitivity | Specificity | Positive predictive value | Negative predictive value | Accuracy rate | Youden index | |||
|---|---|---|---|---|---|---|---|---|---|
| Malignant Benign | |||||||||
| CEUS | Malignant | 23 | 5 | 79.3% | 91.5% | 82.1% | 90% | 87.5% | 0.708 |
| Benign | 6 | 54 | |||||||
| ARFI (SWV) | Malignant | 22 | 3 | 75.9% | 94.9% | 88.0% | 88.9% | 88.6% | 0.708 |
| Benign | 7 | 56 | |||||||
| Both | Both negative or one positive | 27 | 6 | 93.1% | 89.8% | 81.8% | 96.3% | 90.9% | 0.829 |
| Both negative | 2 | 53 | |||||||
FIGURE 2Papillary thyroid carcinoma. (a) Two-dimensional ultrasound showing a hypo-echoic nodule with calcification. (b) CEUS showing heterogeneous low enhancement. (c) The SWV value was X.XX m/s.
FIGURE 3Papillary thyroid carcinoma. (a) Color Doppler ultrasound showing rich blood flow in the nodule. (b) CEUS showing heterogeneous homogeneous equal enhancement. (c) The SWV value was 1.53 m/s.
FIGURE 4Thyroid follicular carcinoma. (a) Color Doppler ultrasound showing rich blood flow in the nodule. (b) CEUS showing heterogeneous homogeneous high enhancement. (c) The SWV value was 1.88 m/s.
FIGURE 5Thyroid adenoma. (a) Color Doppler ultrasound showing circumferential blood flow around the nodule. (b) CEUS showing ring enhancement. (c) The SWV value was 2.13 m/s.
FIGURE 6Nodular goiter. (a) Color Doppler ultrasound showing a hypo-echoic nodule with coarse calcification. (b) CEUS showing heterogeneous low enhancement. (c) The SWV value was X.XX m/s.