Literature DB >> 19856256

Real-time elastography and contrast-enhanced ultrasound for the assessment of thyroid nodules.

M Friedrich-Rust1, A Sperber, K Holzer, J Diener, F Grünwald, K Badenhoop, S Weber, S Kriener, E Herrmann, W O Bechstein, S Zeuzem, J Bojunga.   

Abstract

OBJECTIVE: Work-up of thyroid nodules remains challenging. Recent technologies enable determination of tissue elasticity and perfusion using ultrasound devices. The aim of the present study was to evaluate real-time elastography (RTE) and contrast-enhanced ultrasound with Sonovue (CEUS) for the differentiation of benign and malignant thyroid nodules.
MATERIALS AND METHODS: Inclusion criteria were: nodules ≥1 cm, non-functioning or hypo-functioning on radionuclide scanning, and cytological/histological assessment. All patients received conventional ultrasound, RTE and CEUS. RTE was classified as: Elasticity-Score (ES)1 = soft, ES2 = predominantly soft, ES3 = predominantly hard, ES4 = hard nodule. CEUS-video clips were digitally recorded and analyzed using time-intensity-curves within selected regions-of-interest.
RESULTS: Fifty-three nodules in 50 patients were available for analysis. Forty-six nodules were benign on cytology/histology, 6 nodules were papillary carcinoma and one nodule was a follicular carcinoma. Nodule margin irregularity was the ultrasound pattern most predictive of malignancy with sensitivity 57% (95% confidence interval: 18-90%) and specificity 85% (71-94% p<0.05). When using ES3&4 for the diagnosis of malignant nodules sensitivity and specificity were 86% (42-99.7%) and 87% (75-95%), respectively (p = 0.0003). The only malignant nodule missed with RTE was a follicular carcinoma. Sensitivity for the diagnosis of papillary carcinoma therefore was 100%. No specific CEUS pattern could be identified to differentiate between benign and malignant nodules.
CONCLUSIONS: RTE seems to be a useful tool in the work-up of thyroid nodules to exclude papillary thyroid cancer. However, follicular carcinoma remains a challenging problem. CEUS did not improve the characterization of thyroid nodules in this preliminary study. © J. A. Barth Verlag in Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19856256     DOI: 10.1055/s-0029-1237701

Source DB:  PubMed          Journal:  Exp Clin Endocrinol Diabetes        ISSN: 0947-7349            Impact factor:   2.949


  38 in total

1.  Shear wave elastography of thyroid nodules in routine clinical practice: preliminary observations and utility for detecting malignancy.

Authors:  Kunwar S S Bhatia; Cina S L Tong; Carmen C M Cho; Edmund H Y Yuen; Yolanda Y P Lee; Anil T Ahuja
Journal:  Eur Radiol       Date:  2012-05-30       Impact factor: 5.315

2.  Diagnostic value of contrast-enhanced ultrasound in solid thyroid nodules with and without enhancement.

Authors:  Qiong Wu; Yan Wang; Yi Li; Bing Hu; Zhi-Yan He
Journal:  Endocrine       Date:  2016-01-05       Impact factor: 3.633

3.  Clinical value of elasticity imaging and contrast-enhanced ultrasound in the diagnosis of papillary thyroid microcarcinoma.

Authors:  Fengsheng Li; Jianlei Zhang; Yunmei Wang; Liwen Liu
Journal:  Oncol Lett       Date:  2015-06-17       Impact factor: 2.967

4.  Association between real-time contrast-enhanced ultrasound characteristics and thyroid carcinoma size.

Authors:  Zhang Yuan; Jiang Quan; Zhang Yunxiao; Chen Jian; H E Zhu
Journal:  Mol Clin Oncol       Date:  2015-05-15

5.  Is there a real diagnostic impact of elastosonography and contrast-enhanced ultrasonography in the management of thyroid nodules?

Authors:  Massimo Giusti; Davide Orlandi; Giulia Melle; Barbara Massa; Enzo Silvestri; Francesco Minuto; Gianni Turtulici
Journal:  J Zhejiang Univ Sci B       Date:  2013-03       Impact factor: 3.066

6.  Elastographic techniques of thyroid gland: current status.

Authors:  Massimiliano Andrioli; Luca Persani
Journal:  Endocrine       Date:  2014-02-07       Impact factor: 3.633

Review 7.  The role of elastography in evaluating thyroid nodules: a literature review and meta-analysis.

Authors:  Vik Veer; Srikanth Puttagunta
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-07-06       Impact factor: 2.503

8.  Diagnostic performance of elastography in cytologically indeterminate thyroid nodules.

Authors:  Francesca Garino; Maurilio Deandrea; Manuela Motta; Alberto Mormile; Federico Ragazzoni; Nicola Palestini; Milena Freddi; Guido Gasparri; Enrico Sgotto; Donatella Pacchioni; Paolo Piero Limone
Journal:  Endocrine       Date:  2014-10-02       Impact factor: 3.633

9.  Contrast-enhanced ultrasound and real-time elastography in the differential diagnosis of malignant and benign thyroid nodules.

Authors:  Xin Sui; Huai-Jun Liu; Hong-Li Jia; Qin-Mao Fang
Journal:  Exp Ther Med       Date:  2016-05-17       Impact factor: 2.447

10.  Utility and interobserver agreement of ultrasound elastography in the detection of malignant thyroid nodules in clinical care.

Authors:  S Merino; J Arrazola; A Cárdenas; M Mendoza; P De Miguel; C Fernández; T Ganado
Journal:  AJNR Am J Neuroradiol       Date:  2011-11-03       Impact factor: 3.825