Re-exposure in cone beam CT of the dentomaxillofacial region: a retrospective study.

Yasamin Habibi1, Edriss Habibi2, Bilal Al-Nawas1.   

Abstract

METHODS: : In a retrospective cohort study CBCT images of 4986 patients from the patient database from the Department of Oral Radiology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany were included and the rate of re-exposures was counted. Patients were stratified into those who received a scan with the small field-of-view CBCT or the large field-of-view CBCT. The effect of patient-related parameters as age and gender was implicated. As a further device-specific parameter, the statistical analysis included whether the selection of the field of view due to the device type had a significant influence on the occurrence of re-exposures. Furthermore, the rescans were analyzed with regard to their causes.
RESULTS: : In total, CBCT images of 82 (1.6%) patients had to be repeated. Looking at the two different devices, in 42 (1.3%) patients that received a scan with the large field-of-view CBCT and in 40 (2.3%) patients that received a scan with the small field-of-view CBCT respectively needed a retake. There was no statistically significant correlation between age and gender to retakes. For the small field-of-view-size significantly more retakes were observed than for the large one. With 46% motion artifacts were the most frequent causes for a re-exposure of the patient.
CONCLUSIONS: : Gender and age did not have an impact on the occurrence of re-exposures. Patients who received a scan with the small field-of-view CBCT were significantly more often rescanned than those with the large field-of-view CBCT.

Entities:  

Keywords:  CBCT; large field-of-view CBCT; small field-of-view CBCT

Mesh:

Year:  2019        PMID: 30540920      PMCID: PMC6476354          DOI: 10.1259/dmfr.20180184

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  31 in total

1.  Effect of dose reduction in digital dental panoramic radiography on image quality.

Authors:  B Dannewitz; Stefan Hassfeld; P Eickholz; J Mühling
Journal:  Dentomaxillofac Radiol       Date:  2002-01       Impact factor: 2.419

2.  The ALARA (as low as reasonably achievable) concept in pediatric CT intelligent dose reduction. Multidisciplinary conference organized by the Society of Pediatric Radiology. August 18-19, 2001.

Authors: 
Journal:  Pediatr Radiol       Date:  2002-03-06

3.  [Digital volume tomography (DVT) and multislice spiral CT (MSCT): an objective examination of dose and image quality].

Authors:  Y Kyriakou; D Kolditz; O Langner; J Krause; W Kalender
Journal:  Rofo       Date:  2010-10-04

4.  ALARA still applies.

Authors:  Allan G Farman
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2005-10

5.  Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT.

Authors:  J B Ludlow; L E Davies-Ludlow; S L Brooks; W B Howerton
Journal:  Dentomaxillofac Radiol       Date:  2006-07       Impact factor: 2.419

6.  Maxillofacial 3-dimensional image analysis for the diagnosis of facial asymmetry.

Authors:  Hyeon-Shik Hwang; Chung Hyon Hwang; Ki-Heon Lee; Byung-Cheol Kang
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-12       Impact factor: 2.650

7.  Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT.

Authors:  F G Draenert; E Coppenrath; P Herzog; S Müller; U G Mueller-Lisse
Journal:  Dentomaxillofac Radiol       Date:  2007-05       Impact factor: 2.419

8.  Three-dimensional diagnostics, planning and implementation in implantology.

Authors:  J Neugebauer; L Ritter; R Mischkowski; J E Zöller
Journal:  Int J Comput Dent       Date:  2006-10       Impact factor: 1.883

9.  What is cone-beam CT and how does it work?

Authors:  William C Scarfe; Allan G Farman
Journal:  Dent Clin North Am       Date:  2008-10

Review 10.  Current concepts in maxillofacial imaging.

Authors:  Rudolf Boeddinghaus; Andy Whyte
Journal:  Eur J Radiol       Date:  2007-12-20       Impact factor: 3.528

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.